DRAFT Tentlabs Application Note AN.07 Volume Control



Vergelijkbare documenten
Procedure Reset tv-toestellen:

EM7680 Firmware Update by Micro SD card

L.Net s88sd16-n aansluitingen en programmering.

MyDHL+ Van Non-Corporate naar Corporate

L.Net s88sd16-n aansluitingen en programmering.

HANDLEIDING - ACTIEVE MOTORKRAAN

Quick start guide. Powerbank MI Mah. Follow Fast All rights reserved. Page 1

NEDERLANDS. Display Instructies. Knoppen. Geeft afwisselend Tijd, Datum en Temperatuur weer, kan ook ingesteld worden op enkel tijd

EM7680 Firmware Update by Micro SD card or USB

EM7680 Firmware Update by OTA

Shipment Centre EU Quick Print Client handleiding [NL]

Interface tussen Stuurbediening en Sony autoaudio

EM7680 Firmware Update by Micro SD card or USB stick

Firewall van de Speedtouch 789wl volledig uitschakelen?

Low Noise Power Supply for the Logitech Squeezebox Duet. Technical Description

Introductie in flowcharts

Handleiding Digipass DP310

EM7580 Firmware Update by Micro SD card

SMS Manual. SMS Module. User Manual INNOVATIVE & COMPACT EASY TO PROGRAM LOW COST FACTOR U p d a t e d : October 12,

General info on using shopping carts with Ingenico epayments

Handleiding Zuludesk Parent

Settings for the C100BRS4 MAC Address Spoofing with cable Internet.

256 kb Memory in NMS 8250, 8255 and 8280

SAMPLE 11 = + 11 = + + Exploring Combinations of Ten + + = = + + = + = = + = = 11. Step Up. Step Ahead

Het is geen open boek tentamen. Wel mag gebruik gemaakt worden van een A4- tje met eigen aantekeningen.

IOS and Android APP instruction

FOR DUTCH STUDENTS! ENGLISH VERSION NEXT PAGE. Toets Inleiding Kansrekening 1 8 februari 2010

2019 SUNEXCHANGE USER GUIDE LAST UPDATED

FAAC DRIVER. Driver install procedure for FAAC boards. Installatieprocedure voor driver voor FAAC-kaarten.

OUTDOOR HD DOME IP CAMERA PRODUCT MANUAL GB - NL

Inleiding. Inhoud. Marble Automation MS-5B 2

(1) De hoofdfunctie van ons gezelschap is het aanbieden van onderwijs. (2) Ons gezelschap is er om kunsteducatie te verbeteren

SPL D2 MKII GEBRUIKSAANWIJZING USER MANUAL

Function checklist for the ML-350 or XL-350 with a print set. Missing loop.

DALISOFT. 33. Configuring DALI ballasts with the TDS20620V2 DALI Tool. Connect the TDS20620V2. Start DALISOFT

SPX Model A-360 Azimuth Antenna Rotor Model 1 & 2

Handleiding Installatie ADS

LDAP Server on Yeastar MyPBX & tiptel 31xx/32xx series

Het beheren van mijn Tungsten Network Portal account NL 1 Manage my Tungsten Network Portal account EN 14

User manual Gebruikershandleiding. Version 1.0 March

OUTDOOR HD BULLET IP CAMERA PRODUCT MANUAL

MyDHL+ ProView activeren in MyDHL+

e-dr DISPLAY GEBRUIKERS HANDLEIDING Makes you want to /crystalyteeu drive electric you electric Makes want to drive

PLUS & PRO. Addendum installatie aanvullende MID 65A kwh-meter - Addendum installation additional MID 65A kwh-meter SET

Automatische opname inrichting Collegezaal

EM6250 Firmware update V030507

BathySurvey. A Trimble Access hydrographic survey module

ICARUS Illumina E653BK on Windows 8 (upgraded) how to install USB drivers

MyDHL+ Uw accountnummer(s) delen

Add the standing fingers to get the tens and multiply the closed fingers to get the units.

SPX AX-400 Azimuth & Elevation antenna rotator Model 1 & 2

How to install and use dictionaries on the ICARUS Illumina HD (E652BK)

Systeem Wand Samenstellings Applicatie. Cabinet configuration tool. Nederlandse handleiding

The upside down Louisa tutorial by Dorothée: Noortjeprullemie.blogspot.be Written for Compagnie M.: m.com

2000 Volkswagen Passat GLS


EM7680 Firmware Auto-Update for Kodi 17.2

RECEPTEERKUNDE: PRODUCTZORG EN BEREIDING VAN GENEESMIDDELEN (DUTCH EDITION) FROM BOHN STAFLEU VAN LOGHUM

Hoe met Windows 8 te verbinden met NDI Remote Office (NDIRO) How to connect With Windows 8 to NDI Remote Office (NDIRO

Chapter 4 Understanding Families. In this chapter, you will learn

Preschool Kindergarten

CTI SUITE TSP DETAILS

Integrated Remote Commander

Alistair LED stairwell luminaire Handleiding Alistair (UC03 sensor)

Rhythm of Light. Susanne de Graef, Montagehandleiding / Instruction manual

MyDHL+ Tarief berekenen

PIR DC-SWITCH. DC Passive infra-red Detector. Model No. PDS-10 GEBRUIKSAANWIJZING/INSTRUCTION MANUAL

Instructions assembly Decoderprintje 2

ANT S KINGDOM Here is some advice for setting up your Master Ant Farm!

Plotten. technisch tekenwerk AUTOCAD 2000

Group work to study a new subject.

Activant Prophet 21. Prophet 21 Version 12.0 Upgrade Information

Registratie- en activeringsproces voor de Factuurstatus Service NL 1 Registration and activation process for the Invoice Status Service EN 10

EazyLAN Gebruikershandleiding


AKTIEVE MOTORKRAAN - ACTIVE MOTORVALVE

Recom PDA service software Remeha Avanta

it600 Smart Home Range

Hoe te verbinden met NDI Remote Office (NDIRO): Apple OS X How to connect to NDI Remote Office (NDIRO): Apple OS X

Leeftijdcheck (NL) Age Check (EN)

Quality requirements concerning the packaging of oak lumber of Houthandel Wijers vof ( )

Aim of this presentation. Give inside information about our commercial comparison website and our role in the Dutch and Spanish energy market

Alistair LED stairwell luminaire Handleiding Alistair (UC03 sensor)

!!!! Wild!Peacock!Omslagdoek!! Vertaling!door!Eerlijke!Wol.!! Het!garen!voor!dit!patroon!is!te!verkrijgen!op! Benodigdheden:!!

ALGORITMIEK: answers exercise class 7

Find Neighbor Polygons in a Layer

I.S.T.C. Intelligent Saving Temperature Controler

MyDHL+ Exportzending aanmaken

Daylight saving time. Assignment

1. Voor het installeren wordt geadviseerd een backup te maken van uw database en bestanden.

04/11/2013. Sluitersnelheid: 1/50 sec = 0.02 sec. Frameduur= 2 x sluitersnelheid= 2/50 = 1/25 = 0.04 sec. Framerate= 1/0.

Alistair LED stairwell luminaire Handleiding Alistair (Emergency UC03 sensor)

GS1 Data Source. Guide to the management of digital files for data suppliers and recipients

PANEELRADIATOR - Type PR Handleiding. PANEL RADIATOR - Type PR Manual

Registratie- en activeringsproces voor de Factuurstatus Service NL 1 Registration and activation process for the Invoice Status Service EN 11

LONDEN MET 21 GEVARIEERDE STADSWANDELINGEN 480 PAGINAS WAARDEVOLE INFORMATIE RUIM 300 FOTOS KAARTEN EN PLATTEGRONDEN

Transcriptie:

DRAFT Tentlabs Application Note AN.07 Volume Control

Introduction This Note applies to the Tentlabs Volume Control module. It shows how to connect the module as: Stand alone control Volume control in existing equipment An FAQ is added to help trouble shooting, and the specifications are listed for reference. Purpose The Tentlabs volume control serves as a masetr volume control. It can replace existing controls or can be used in new equipment. Electrical safety Within electronic equipment, during building and surely when finished, AC mains voltages and high DC voltages exist. Care should be taken as long as the cabinet is not closed and the equipment has been connected to the mains. The user remains responsible for his own and others safety and damage of the equipment. Following the instructions however will avoid hazard and electrical shock. Liability Tentlabs accepts no liability at all from any potential damage or injury that may occur when assembling, connecting or using the negative bias supply or any of its sub parts and assemblies. Warrantee The warrantee on the Tentlabs module is 5 years, assumed they are applied and used according the instructions in this Application Note.

Introduction 64 steps of attenuation are achieved with 6 Omron G6K relays, controlling 12 Dale RN6 resistors in parallel configuration. This is a fundamental difference compared to other attenuators, which usually have more contacts or resistors in their signal way. A micro controller controls the relays. A second micro controller on the display section takes care of remote control and decoding, and communicates with the other micro to achieve correct volume and input settings. It also displays these settings. Power supply consists of a low drop 5V regulator. On board rectifiers and decoupling capacitors assure proper functioning of the whole unit, being powered by either AC or DC. Additionally, a power on/off signal is present to directly drive an external relay, which in turn can switch a power amplifier, or fulfill other functions. In power off mode, the controller of the volume control remains active, with a very low standby power.

General Notes This Application Note describes how to set up systems using Tentlabs modules. Enthousiastic hobbyists may want to fully build their own surrounding electronics. For those, technical information is available on the Tentlabs website. Some important notes for the CDpro however are: Installing the module - Mechanical The drawing below facilitates the mounting process

The back plane drawing is shown here

1. Connecting the volume control Power supply. Any AC or DC voltage between 6 and 10V can be connected as shown below. A second unit can be powered using the parallel connectors. In that case the current consumption doubles. The power supply is connected to the audio ground using a parallel network of of 10kΩ and 1uF. Connecting a stand-by relay A relay can be connected as shown below. This relay can be used to switch a (pre)amplifier into standby, using the remote control.

2. Connecting the volume control The front panel PCB is connected using the 5-wire coloured cable and a connector. A second relay module can be controlled using the same front panel PCB. A 2 wire interface (blue-green) does the job. This option is required if balanced use of the volume control is needed. See also section

3. Connecting the volume control Inserting a phono pre amplifier. Input 4 can be transformed to a phono input. Remove resistors R16 and R17, and connect a phono pre-amp as shown below. Use screened (oaxial) wiring, and connect the screen to ground on both sides.

4. Connecting the volume control Inserting a line output buffer to create an active output can be done as shown below

5. Connecting the volume control Balanced use. A second module is reuired. The controller conecton (cascade mode) is shown in chapter 2. The XLR conections are shown below. For the sake of transparency, only channel 1 is wired. Succesive channels are wired in a similar way.

Programming the volume control In order to use a remote control, the volume control has to learn the sent codes from the remote. This chapter is a step-by-step tutorial on how to do this. 1. Turn the volume control (or the device in which it is built) off. (Do not use the stand-by function, really turn of the power supply). 2. Choose a button on the remote, which you do not want to use for any of the volume control functions (so do not choose buttons which you would like to assign to any of the functions in step 4). This button is from here on referred to as the program button. 3. When the volume control is turned on the display will show the letter P. This means that the volume control is now in program mode and it is now possible to program the volume control. After a short while this indication will disappear and the volume control will proceed to its normal mode. Now turn on the volume control. 4. By pressing the program button in the program mode, a number will appear next to the letter P. By repeatedly pressing the program button the number will increase in a loop. After number 9 the loop returns to 1. The number corresponds to a function of the volume control: P1: Volume up P2: Volume down P3: Mute On/Off P4: Channel up P5: Channel down P6: Directly select channel 1 P7: Directly select channel 4 P8: On/Standby P9: Display remains on / go s dark after a few seconds 5. When the desired function is selected, press a button, which you want to assign to this function. To indicate that the function has been programmed, the display shows the number of the function without the letter P. If desired, you can program other functions by pressing the program button again. 6. If you finished programming the functions, wait for a few seconds. The volume control will automatically turn to the normal mode, and the display will show the current volume setting.

Short manual: 1. Turn vol. ctrl. Off. 2. Choose the programming button 3. Turn vol. ctrl. On. 4. Push the programming button 5. Choose a function you want to program 6. Assign a button to the chosen function (repeat step 4 until 6 if desired) 7. Wait for a few seconds until the display shows the current volume setting Good to know: - Carefully consider which button you would like to assign as programming button. It is only possible to make this choice once. After that, it cannot be changed. - In some cases, the display will show - -. This indicates that the transmitted code cannot be used by the volume control. In this case a different remote control has to be used. - In programming mode, the volume control will automatically proceed to the normal mode if no action is performed for a short amount of time. Because of this behaviour it is necessary to push the required buttons relatively fast after each other. You can experience the timing interval by pressing the programming button and then wait. It is always possible to return to the programming mode by switching the volume control off and then back on.

Het programmeren van de volumeregeling Om een afstandsbediening te kunnen gebruiken moet de volume regeling de codes van die afstandsbediening leren. Het volgende stappenplan geeft aan hoe dit in zijn werk gaat: 1. Zet de volumeregeling (of het apparaat waar de volumeregeling is ingebouwd) uit. (gebruik niet de stand-by functie, maar zorg er voor dat de voeding uit is). 2. kies een knop op de afstandsbediening die u niet wilt gebruiken voor een functie van de volume regeling (kies dus geen knop die u wilt toewijzen aan een van de functies in stap 4). Deze knop heet vanaf nu de programmeerknop. 3. Bij het aanzetten van de volumeregeling verschijnt de letter P in beeld. Dat betekent dat u op dat moment de volume regeling kunt programmeren. Deze verdwijnt na een korte tijd om daarna naar de normale toestand te gaan. Zet de volume regeling nu aan. 4. Door nu op de programmeerknop te drukken ziet u achter de P een nummer verschijnen. Door herhaaldelijk op deze knop te drukken zal het nummer steeds 1 stap verder gaan, en na 9 zal deze weer bij 1 beginnen. Het nummer achter de P komt overeen met een functie van de volumeregeling: P1: Volume omhoog P2: Volume omlaag P3: Mute Aan/Uit P4: Kanaal verder P5: Kanaal terug P6: Direct kanaal 1 selectie P7: Direct kanaal 4 selectie P8: Aan/Stand-by P9: Display blijft aan / gaat uit na enkele seconden 5. Wanneer de gewenste te programmeren functie in beeld is drukt u op de knop die u aan die functie toe wilt wijzen. Op dat moment verdwijnt de P een korte tijd om aan te geven dat die functie nu geprogrammeerd is. Wanneer gewenst kunt u weer op de programmeerknop drukken om andere functie te programmeren. 6. Als u klaar bent met programmeren wacht u enkele seconden tot het display weer naar de normale mode terug gaat. Op dat moment zal het display de huidige volumestand aangeven.

In het kort: 8. Zet de volume regeling uit 9. Kies de programmeerknop 10.Zet de volume regeling aan 11.druk op de programmeerknop 12.Kies een te programmeren functie 13.Ken een knop toe aan de gekozen functie (herhaal stap 4 tot 6 indien gewenst) 14.Wacht enkele seconden tot het volume in beeld is Goed om te weten: - Denk goed na welke knop u wil toewijzen als programmeerknop. Deze keuze is eenmalig mogelijk en daarna niet meer te veranderen. - In enkele gevallen geeft het display - - weer. De uitgezonden code kan dan niet worden gebruikt. Dit betekent dat u een andere afstandsbediening moet gebruiken. - De tijd dat u kunt programmeren is relatief kort. Experimenteer eerst met de programmeerknop hoeveel tijd u per functie heeft om te programmeren. U kunt altijd opnieuw in de programmeermode komen door de volume regeling uit en weer aan te zetten.

Specifications Electrical Input impedance: Output impedance: Input voltage: Current consumption: Volume setting: Channel imbalance: Inputs: 4 Connectors: Remote control: > 40 kω (value depends on volume setting) < 8 kω (value depends on volume setting) 6 to 10V max (AC or DC) This input is connected to audio ground by a parallel circuit of 10kΩ and 1uF 150mA DC, 225mA AC (max values) 64 steps of 1.0 db < 0.15 db Cinch / RCA Can be programmed to Philips / Marantz models and most Sony types Standby output: Open collector, 5V, max 100mA (this current is not included in the current consumption spec) Specifications Mechanical Main PCB size: 120*58*28 mm (W*L*H)(excludes connectors) Hole pitch: 111*49 mm (symmetrical) Display PCB size: Hole pitch: 120*20*8 mm (W*L*H) (excludes control shaft) 111*11 mm (symmetrical) Display PCB small size: 80*20*8 mm (W*L*H) (excludes control shaft) Hole pitch: 71*11 mm (symmetrical) All mounting hole diameters are 3.2 mm All specs and parameters subject to change without prior notice