DC-DC CHARGER. ELOGIC Intelligent DC-DC Batterycharger. Model No. EL 12-12/30 EL 12-24/15 EL 24-12/30 EL 24-24/30 USER MANUAL, GEBRUIKSAANWIJZING



Vergelijkbare documenten
PIR DC-SWITCH. DC Passive infra-red Detector. Model No. PDS-10 GEBRUIKSAANWIJZING/INSTRUCTION MANUAL

liniled Cast Joint liniled Gietmof liniled Castjoint

Quick start guide. Powerbank MI Mah. Follow Fast All rights reserved. Page 1

PC-series. P a g i n a 2. P a g e 7


Whisper Power Battery Link WBI WBL-120

EU Declaration of Conformity and safety instructions EU Conformiteitsverklaring en veiligheidsinstructies ISC 230B

PANEELRADIATOR - Type PR Handleiding. PANEL RADIATOR - Type PR Manual

EU Declaration of Conformity and safety instructions EU Conformiteitsverklaring en veiligheidsinstructies

SPX Model A-360 Azimuth Antenna Rotor Model 1 & 2

HANDLEIDING - ACTIEVE MOTORKRAAN

Alistair LED stairwell luminaire Handleiding Alistair (Emergency UC03 sensor)

OUTDOOR HD BULLET IP CAMERA PRODUCT MANUAL

Alistair LED stairwell luminaire Handleiding Alistair (UC03 sensor)

EazyLAN Gebruikershandleiding

POWERXTREME X75 / X125

EU Declaration of Conformity and safety instructions EU Conformiteitsverklaring en veiligheidsinstructies UNIGAS 300

Introductie in flowcharts

SPID Azimuth antenna rotator Type: RAK

SPX AX-400 Azimuth & Elevation antenna rotator Model 1 & 2

Settings for the C100BRS4 MAC Address Spoofing with cable Internet.

Limpid Light. design Esther Jongsma & Sam van Gurp, Montagehandleiding / Assembly Instructions

Function checklist for the ML-350 or XL-350 with a print set. Missing loop.

OUTDOOR HD DOME IP CAMERA PRODUCT MANUAL GB - NL

PLUS & PRO. Addendum installatie aanvullende MID 65A kwh-meter - Addendum installation additional MID 65A kwh-meter SET

L.Net s88sd16-n aansluitingen en programmering.

Alistair LED stairwell luminaire Handleiding Alistair (UC03 sensor)

SRL-1 Audio controlled cirquit breaker GEBRUIKSAANWIJZING USER MANUAL

ICARUS Illumina E653BK on Windows 8 (upgraded) how to install USB drivers

Mobile concrete base

NEDERLANDS. Display Instructies. Knoppen. Geeft afwisselend Tijd, Datum en Temperatuur weer, kan ook ingesteld worden op enkel tijd

SPL D2 MKII GEBRUIKSAANWIJZING USER MANUAL

I.S.T.C. Intelligent Saving Temperature Controler

EM7680 Firmware Update by OTA

Presentation Fire fighter safety switch

INSULATION GUARD 25AMP INSULATION GUARD. Model No. IG-25 IG-25C USER MANUAL, GEBRUIKSAANWIJZING

ATD Floor Fan Owner s Manual Features:

WeZoWe - Werkgroep Zonnepanelen Westeinde. Het adres voor al uw installatiewerk!!

Today s class. Digital Logic. Informationsteknologi. Friday, October 19, 2007 Computer Architecture I - Class 8 1


Zone 1 and zone 2 Zone 21 and zone 22

MOBILITY POWER PACK. Installatie instructies en gebruiksaanwijzing. Version 1.00

HANDLEIDING Joy Sport Relax

2 Port DVI VGA Dual Monitor KVM Switch USB with Audio & USB 2.0 Hub

L.Net s88sd16-n aansluitingen en programmering.

Mounting ceiling & wall

Handleiding Remote Engineer Portal

TOEGANG VOOR NL / ENTRANCE FOR DUTCH : lator=c&camp=24759

EM6250 Firmware update V030507

SPID Azimuth antenna rotator Type: BIG-RAK

EC DECLARATION OF CONFORMITY

Gebruikershandleiding

Installation & Usage Biometric Reader - NL. Biometric Reader - NL. Productie Versie: 7.0. Versienummer Handleiding: 1.0.2

Zone 1 and zone 2 Zone 21 and zone 22

EM7580 Firmware Update by Micro SD card

EM7680 Firmware Auto-Update for Kodi 17.2

User manual Gebruikershandleiding. Version 1.0 March

SHP-TS TwinArc SA SHP-TS 400W TWINARC E40 SL PRODUCT OVERVIEW

Zelflimiterende verwarmingskabel type ESR Selflimiting heating cable type ESR

FOR DUTCH STUDENTS! ENGLISH VERSION NEXT PAGE. Toets Inleiding Kansrekening 1 8 februari 2010

Hoe te verbinden met NDI Remote Office (NDIRO): Apple OS X How to connect to NDI Remote Office (NDIRO): Apple OS X

Citadel Composition. NL Installatie handleiding DE Installationsanleitung EN Installation manual

Johto. Flexible light

Presenter SNP6000. Register your product and get support at NL Gebruiksaanwijzing

FOR DUTCH STUDENTS! ENGLISH VERSION NEXT PAGE

Het voorspellen van de levensduur van LED verlichting met gebruik van omgevingstesten En enkele voorbeelden van faal mechanismen

Snelladen in stedelijke gebieden. Menno Kardolus Melvin Venema

EM7680 Firmware Update by Micro SD card

Installatie handleiding Emergency Battery System.

FSW-VW-2X2 FSW-VW. Handleiding / Manual

ATEX serie ATEX range

Outdoor External Strobe Siren. ADD-ON DEVICE Quickstart Guide. What's inside: 1x Outdoor External Strobe Siren

epson software v FF8F706A2C13685F05A2EFC3499C0 Epson Software V330 1 / 6

Danfoss Heating. ORT-01 Electronic modulating room thermostat for OpenTherm appliances Installation and User Guide

Gebruikershandleiding

Activant Prophet 21. Prophet 21 Version 12.0 Upgrade Information

Technical Manual Card Reader - Biometric Fingerprint

CTI SUITE TSP DETAILS

Universe Square Double / Triple

Rhythm of Light. Susanne de Graef, Montagehandleiding / Instruction manual

Remote sensor series

Installatie van Windows 10 op laptops. Windows 10 installation on laptops

Installatie- en gebruikershandleiding. Pulse-out module

Technical Manual Biometric - Fingerprint Reader

HANDLEIDING Joy Sport Marathon

Flybye. Ernst Koning, Montagehandleiding / Instruction manual

MyDHL+ Van Non-Corporate naar Corporate

BathySurvey. A Trimble Access hydrographic survey module

EVION PWR Pack. NL Handleiding EN Manual. Model: EVION PWR Pack. Contact: BE Leisure BV Bremere HD Wouw Netherlands

Procedure Reset tv-toestellen:

Universe. NL Installatie handleiding DE Installationsanleitung EN Installation manual

DECLARATION FOR GAD approval

INSTALLATIE INSTRUCTIES Alleen geschikt als permanente installatie, onderdelen genoemd in de handleiding kunnen niet buiten gemonteerd worden.

Ultra sound system Installatie Handleiding

SMS Manual. SMS Module. User Manual INNOVATIVE & COMPACT EASY TO PROGRAM LOW COST FACTOR U p d a t e d : October 12,

General info on using shopping carts with Ingenico epayments

Groene industrie POWER QUALITY POWER AND SIGNAL QUALITY. Phoenix Contact B.V

Het is geen open boek tentamen. Wel mag gebruik gemaakt worden van een A4- tje met eigen aantekeningen.

Circulatiepompen voor de Glastuinbouw Pompgrafieken

Installatie handleiding Emergency Battery System.

Transcriptie:

DC-DC CHARGER ELOGIC Intelligent DC-DC Batterycharger Model No. EL 12-12/30 EL 12-24/15 EL 24-12/30 EL 24-24/30 USER MANUAL, GEBRUIKSAANWIJZING Please read the manual before installing your intelligent DC-DC charger

ENGLISH DESCRIPTION ENG Contents Introduction: 3 Theory of operation: 3 Typical Application: 4 Installation recommendations: 4-5 Specification: 6 LED symbol 6 Warranty 7 Declaration of conformity 14 NEDERLANDSE BESCHRIJVING NL Inhoud Inleiding 9 Werking 9 Schema 10 Installatie aanbevelingen 10-11 Specificatie: 12 LED indicatie 12 Garantie 13 Conformiteitsverklaring 14 2

INTRODUCTION ENG The Elogic series Battery Charger is a high performance battery charger that has the ability to precisely charge 12 Vdc battery banks. The ELOGIC series incorporates advanced battery charging technology, correctly charging batteries automatically in a safe manner to ensure speedy charging while maintaining battery life. This advanced design keeps batteries in top condition and minimizes battery failure, resulting in maximum battery life. THEORY OF OPERATION The original alternator program used to be 14.4V as long as the engine was running and manufacturers have developed charge programs to reduce energy and hence fuel wastage. Different vehicle manufacturers use different charging profiles but even the same manufacturers continuously update their charge programs. The Elogic charger takes account of all these programs and charges as long as the vehicle battery is more than 12.5V. Normal operations: The Elogic series will provide 30 Amp continuous output maximum for a 12V system and 15 Amp for a 24V system depending on the charge state of the battery. The Elogic will automatically switch to float after the boost charge. The battery will never overcharge. This is independent of the alternator voltage. Overload condition: The Elogic series is overload protected when the 12 Volt output exceeds 30 Amps. The overload will not damage the charger. The El series is also protected for overheating and will turn off or lower the current charging capacity until the temperature falls below the maximum safe operating temperature. Voltage sensing or Ignition contact: The charger needs to have a +12 Volt connection (Yellow Wire) either via the vehicle ignition switch ON/OFF or if this is difficult to obtain then voltage sensing can be used via direct connection of the (Yellow Wire) as close to the +12 Volt positive terminal of the vehicle primary battery as possible. The charger will turn off if the voltage sensing if the ignition feed is below 12.4 Vdc regardless of the load current. 3

TYPICAL APPLICATION ENG INSTALLATION RECOMMENDATIONS Fusing: A fault protection device must be installed between the Elogic series charger and the power source (battery). A fault protection device would be any fuse or circuit breaker properly rated for the maximum DC input current. Minimum Wire and Fuse Sizes: Connect Elogic series as close as possible to the auxiliary battery. If the distance between the Elogic series and the auxiliary battery is shorter than 1.5 meters use a 6mm² cable if above 1.5 meters use 16mm² cable, and protected by a 40 Amp fuse or circuit breaker. Using the same size cable for all circuits is recommended. Install adequate fuse protection if smaller cables are used. Mounting Location: The DC to DC charger may be mounted in any orientation, however for optimum cooling, mount the charger with fins vertical. It also performs best if secured to a metal surface. Environmental Protection: Protect the unit from direct exposure to moisture such as high-pressure washing, rain, etc. 4

5 ENG

ENG Specification: Model Elogic EL 12-12/30 Elogic EL 12-24/15 Elogic EL24-24/15 Elogic EL24-12/30 Input Voltage Range 8-15Vdc 8-15Vdc 16-30Vdc 16-30Vdc Output Voltage 10-15Vdc 20-30Vdc 20-30Vdc 10-15Vdc Output Current 30 Amp 15Amp 15 Amp 30 Amp Output Riple and Noise less then 50mV RMS less then 50mV RMS less then 50mV RMS less then 50mV RMS Efficiciency 93% 93% 93% 93% Standby Current (in low power mode) <2mA <2mA <3mA <3mA Operation Temperature -30 to 70 C -30 to 70 C -30 to 70 C -30 to 70 C Humidity Max. 95% Max. 95% Max. 95% Max. 95% non condensing non condensing non condensing non condensing Protection over current Yes Yes Yes Yes over temperature Yes Yes Yes Yes over voltage (36VMax) Yes Yes Yes Yes External fuse Input 40 Amp 40 Amp 20 Amp 40 Amp Voltage sensing 1 Amp 1 Amp 1 Amp 1 Amp External fuse Output 40 Amp 20 Amp 20 Amp 40 Amp Connections Input Torberry connector Torberry connector Torberry connector Torberry connector Connector Output 16mm² via busbar 16mm² via busbar 16mm² via busbar 16mm² via busbar Approval EMC/ E11 EMC/ E11 EMC/ E11 EMC/ E11 IP rating IP50 IP50 IP50 IP50 Weight 1.0 kg 1.0 kg 1.0 kg 1.0 kg LED Status/Alarm LED will flash amber during the pre-charging phase (flat secondary battery detected <8V) and in Bulk Charging mode. LED will flash green during the float charging mode. LED will flash red in a sequence to indicate a fault has been detected (charger off and in alarm mode). 6

WARRANTY ENG Samlex warrants this product to be free from defects in workmanship or materials for 24 months from the date of purchase. During this period Samlex will repair the defective product free of charge. Samlex is not responsible for any costs of the transport of this product. This warranty is void if the product has suffered any physical damage or alteration, either internally or externally, and does not cover damage arising from improper use 1) or from use in an unsuitable environment. This warranty will not apply where the product has been misused, neglected, improperly installed or repaired by anyone other than Samlex. Samlex is not responsible for any loss, damage or costs arising from improper use, use in an unsuitable environment or improper installing, setup and malfunctioning of the product. Since Samlex cannot control the use and installation (according to local regulations) of their products, the customer is always responsible for the actual use of these products. Samlex products are not designed for use as critical components in life support devices or systems, which can potentially harm humans and/or the environment. The customer is always responsible when implementing Samlex products in these kinds of applications. Samlex does not accept any responsibility for any violation of patents or other rights of third parties, resulting from the use of the Samlex product. Samlex keeps the right to change product specifications without previous notice. 1) Examples of improper use are :- too high input voltage applied- wrong shunt connection- applying battery voltage to shunt input- mechanically stressed enclosure or internals due to harsh handling and/or incorrect packaging.- contact with any liquids or oxidation caused by condensation. 7

ENGLISH DESCRIPTION ENG Contents Introduction: 3 Theory of operation: 3 Typical Application: 4 Installation recommendations: 4-5 Specification: 6 LED symbol 6 Warranty 7 Declaration of conformity 14 NEDERLANDSE BESCHRIJVING NL Inhoud Inleiding 9 Werking 9 Schema 10 Installatie aanbevelingen 10-11 Specificatie: 12 LED indicatie 12 Garantie 13 Conformiteitsverklaring 14 8

INLEIDING NL De Elogic serie acculader is een kwalitatieve hoogwaardige batterijlader die 12 en 24 VDC accu banken op de juiste manier oplaad. De ELOGIC serie bevat geavanceerde elektronica en software die ervoor zorgt dat voertuigen met een Euro5/6 norm dynamo een 2e accu ( accessoire accu) systeem goed kan opladen. Dit geavanceerde ontwerp houdt accu's in topconditie en minimaliseert uitval, dat resulteert in een maximale levensduur van de accu. WERKING Een dynamo leverde in het verleden altijd rond de 14,4 Volt. Tegenwoordig zijn de voertuigen zuiniger en werkt de dynamo met andere laad profielen. Verschillende autofabrikanten gebruiken verschillende profielen en werken de profielen continue bij. De Elogic lader houdt rekening met al deze programma's, zolang de accu spanning hoger dan 12,5V is. Normale werking: De Elogic zal maximaal 30 ampère bij een 12 volts systeem en maximaal 15 ampère bij een 24volt systeem leveren afhankelijk van het laadstadium van de 2e accu. Na een boostlading (snelladen) zal de lader automatisch in float (naladen) gaan, waardoor de 2e accu nooit overladen wordt. Dit alles onafhankelijk van de hoogte van de Dynamo spanning. Voorwaarde Overbelasting: De Elogic serie is beveiligd en zal nooit meer dan 30 ampère leveren. Bij overbelasting zal de lader niet beschadigen. De Elogic is temperatuurgeregeld en zal hierdoor nooit te warm worden. Bij hoge temperatuur zal de E logic de stroom terug regelen en zo ten alle tijden veilig zijn. Spanningsmeting of Startcontact: Om te kunnen functioneren moet de elogic via de gele draad verbonden zijn met het startcontact of zo dichtmogelijk bij de pluspool van de startaccu. De lader zal stoppen met laden als het startcontact uit gezet wordt, of als de spanning van de startaccu onder de 12,4 volt komt, afhankelijk van hoe de elogic aangesloten is. 9

SCHEMA NL INSTALLATIE AANBEVELINGEN Zekering: Zekeringen moeten volgens het schema in deze handleiding geplaatst worden. Zie hoofdstuk specificaties voor de juiste zekering waarde. Pas de zekering waarden aan bij afwijkende diameters en lengtes van de kabel als in hoofdstuk bekabeling genoemd. Bekabeling: Plaats de Elogic zo dicht mogelijk bij het 2e accusijsteem. Als de afstand tussen de Elogic en het 2e batterij sijsteem korter is dan 1,5 meter gebruik dan een kabel van 6mm². Boven de 1,5 meter 16mm² kabel. Montage Locatie: De Elogic kan in elke richting gemonteerd worden, maar voor een optimale koeling, plaats dan de lader met koelribben verticaal. De beste koeling word verkregen bij montage op een metalen oppervlak. Omgevingsfactoren: Bescherm het apparaat tegen directe blootstelling aan vocht, zoals hoge - druk reiniger, regen, enz. 10

11 NL

NL Specificatie: Model Elogic EL 12-12/30 Elogic EL 12-24/15 Elogic EL24-24/15 Elogic EL24-12/30 Input Voltage Range 8-15Vdc 8-15Vdc 16-30Vdc 16-30Vdc Output Voltage 10-15Vdc 20-30Vdc 20-30Vdc 10-15Vdc Output Current 30 Amp 15Amp 15 Amp 30 Amp Output Riple and Noise less then 50mV RMS less then 50mV RMS less then 50mV RMS less then 50mV RMS Efficiciency 93% 93% 93% 93% Standby Current (in low power mode) <2mA <2mA <3mA <3mA Operation Temperature -30 to 70 C -30 to 70 C -30 to 70 C -30 to 70 C Humidity Max. 95% Max. 95% Max. 95% Max. 95% non condensing non condensing non condensing non condensing Protection over current Yes Yes Yes Yes over temperature Yes Yes Yes Yes over voltage (36VMax) Yes Yes Yes Yes External fuse Input 40 Amp 40 Amp 20 Amp 40 Amp Voltage sensing 1 Amp 1 Amp 1 Amp 1 Amp External fuse Output 40 Amp 20 Amp 20 Amp 40 Amp Connections Input Torberry connector Torberry connector Torberry connector Torberry connector Connector Output 16mm² via busbar 16mm² via busbar 16mm² via busbar 16mm² via busbar Approval EMC/ E11 EMC/ E11 EMC/ E11 EMC/ E11 IP rating IP50 IP50 IP50 IP50 Weight 1.0 kg 1.0 kg 1.0 kg 1.0 kg LED Status/Alarm LED knippert geel gedurende de voor-laadfase ( 2e accu spanning < 8V ) en boost laadfase. LED knippert groen in de na-laad (float) fase. LED knippert rood bij lader uit en in de alarm mode. 12

GARANTIE NL Samlex Europe BV (Samlex) garandeert dit product vrij van defecten veroorzaakt in de assemblage of door de gebruikte materialen, tot 24 maanden na de aankoopdatum. Gedurende deze periode neemt Samlex de kosten van eventuele reparatie voor haar rekening. Samlex is niet verantwoordelijk voor de transportkosten van dit product. Deze garantie vervalt wanneer dit product fysiek beschadigd is, zowel extern als intern en 1) dekt geen kosten veroorzaakt door onjuist gebruik of gebruik in een ongeschikte omgeving. Deze garantie is niet geldig wanneer dit product is misbruikt, verwaarloosd, onjuist geïnstalleerd of gerepareerd door iemand anders dan door Samlex is aangewezen. Samlex is niet verantwoordelijk voor enig verlies, schade of kosten voortvloeiende uit onjuist gebruik, installatie, gebruikersinstellingen en storing van dit product. Omdat Samlex geen controle kan uitvoeren op het gebruik en de installatie (volgens lokaal geldende voorschriften) van dit product, is de eindgebruiker ten alle tijden aansprakelijk voor het gebruik hiervan. Dit Samlex product is niet geschikt voor toepassing als kritische component in (medische-) apparatuur of systemen die een potentieel gevaar kunnen vormen voor mens, natuur en milieu. De eindgebruiker is ten alle tijden verantwoordelijk voor de toepassing van dit product in deze applicaties. Samlex accepteert geen verantwoordelijkheid voor mogelijke inbreuk op patenten of andere rechten van derden, verbonden aan het gebruik van dit product. Samlex behoudt het recht om product specificaties te wijzigen zonder voorafgaande aankondiging. 1) Enkele voorbeelden van onjuist gebruik zijn : - het aanbieden van een te hoge ingangsspanning - verkeerd aansluiten. Mechanisch te zwaar belaste behuizing en/of interne onderdelen, vanwege misbruik of incorrecte verpakking - contact met vloeistoffen of oxidatie door condensatie. 13

DECLARATION OF CONFORMITY IMPORTER : SAMLEX EUROPE B.V. ADDRESS : ARIS VAN BROEKWEG 15 1507 BA ZAANDAM THE NETHERLANDS Declares that the following products : PRODUCT TYPE : ELOGIC INTELLIGENT DC-DC CHARGER BRAND: Samlex MODELS : - EL 12-12/30 - EL 12-24/15 - EL 24-12/30 - EL 24-24/30 www.samlex.com www.samlex-solar.com Conform to the requirements of the following Directives of the European Union : E11 Approval Immunity requirements UNECE regulation 10 issue 4 Which covers all aspects of EN50489:2010 The above products are in conformity with the following harmonized standards : Immunity to requirements of EN61204-3 2000 Signed: Marcel van Veen Date: 08-06-2016 Managing Director 14

15

www.samlex.com www.samlex-solar.com