Golden 50 - Specials Voor t Labo blaast 50 kaarsjes uit HETTICH CENTRIFUGES PROMO PAKKETPRIJZEN Mikro 185 Mikro 220 R (gekoeld) Rotofix 32 A Universal 320 Universal 320 R (gekoeld) GELDIG VANAF 1 juni 2016 tot 30 juni 2016 1) Hettich Mikro 185 centrifuge met rotor 24 x 1,5/2 ml - Ref. 1226 Model MIKRO 185 24 1,5/2,0 ml (met rotor 1226) Max. snelheid (tpm) 13.300 Max. RCF ( g) 17008 (met rotor 1226) 262 352 228 Ca.11 kg Mikro 185 50-1203/1226 1175,00 Incl. Rotor 1226
2) Mikro 220 R (gekoeld) Model MIKRO 220 R 30 x 1.5/ 2 ml, 24 x 1.5/2 ml met rotor 2424-B Max. snelheid (tpm) 15.0000 Max. RCF ( g) 21. 382 met Rotor 2424-B Temperatuur -10 C tot +40 C 260 x 281 x 553 mm Ca.28 kg Angle rotor for 24 x 1.5 / 2 ml, max. RCF 21,382 Cat. No. 2424-B Angle rotor for 30 x 1.5 / 2 ml, two-row, max. RCF 20,627 Cat. No. 2427-A Angle rotor for 30 x 0.5 ml, max. RCF 20,376 Cat. No. 2430-B Mikro 220R 50-2405/2424-B 3500,00 Incl. Rotor 2424-B
3) Rotofix 32 A +Swing-out rotor 1619 Model ROTOFIX 32A 4 x 100 ml swing-out rotor Max. snelheid (tpm) 6.000 Max. RCF ( g) 4.226 Swing-out rotor, 6-plaatsen Hoek: 90 RPM max.: 4,000 min -1 RCF max.: 2,701 Cat. No. 1619 257 x 336 x 430 mm Ca.23 kg Swing-out rotor for 4 x 100 ml (90 ), max. RCF 2,630 Cat. No. 1324 Swing-out rotor for 8 x 50 ml (45 ), max. RCF 2,469 Cat. No. 1617 Angle rotor for 6 x 85 ml, max. RCF 4,226 Cat. No. 1620A Rotofix 32 A 50-1206/1619 1.875,00 Incl. Rotor 1619
4) Universal 320 Model Universal 320 4 x 200 ml swing-out rotor 24 capillairen hematocriet Max. snelheid (tpm) 15.000 Max. RCF ( g) 21.382 346 x 401 x 529 mm Ca.31 kg Swing-out rotor for 4 x 100 ml (90 ), max. RCF 4,193 Cat. No. 1494 Angle rotor for 30 x 1.5 / 2 ml, max. RCF 21,255 Cat. No. 1689-A Angle rotor for 6 x 85 ml, max. RCF 9,509 Cat. No. 1620A Cyto rotor for 6 slide preparations, max. RCF 2,039 Cat. No. 1626 Universal 320 50-1401/1324 2.700,00 Incl. rotor 1324 Opmerking : bekers en adapters NIET inclusief USP Safety and comfort in the workplace using carriers with a single-hand clamp lock The clamp lock of the 1560 carrier can be operated without difficulty with just one hand. The carrier can be comfortably carried by the clamp whether the lid is in place or not since, in contrast to the products from other manufacturers, the clamp is mounted on the carrier and not on the lid. If the lid is in place, the carrier can not only be carried with ease, it is also safe to transport. 4. With the clamp in the open position the lid can be easily fitted and removed. 5. With the clamp in the central position the carrier is sealed to prevent aerosol formation and can be safely carried to the centrifuge, workbench or another working space. 6. With the clamp in the close position the carrier can be centrifuged without aerosol formation. The absence of aerosols has been verified by the TÜV in accordance with DIN EN 61010, Part 2-020.
4) Universal 320 R (gekoeld) Model Universal 320 4 x 200 ml swing-out rotor 24 capillairen hematocriet Max. snelheid (tpm) 15.000 Max. RCF ( g) 21.382 Temperatuur -20 C tot + 40 C 346 x 401 x 529 mm Ca.31 kg Swing-out rotor for 4 x 100 ml (90 ), max. RCF 4,193 Cat. No. 1494 Angle rotor for 30 x 1.5 / 2 ml, max. RCF 21,255 Cat. No. 1689-A Angle rotor for 6 x 85 ml, max. RCF 9,509 Cat. No. 1620A Cyto rotor for 6 slide preparations, max. RCF 2,039 Cat. No. 1626 Universal 320 R 50-1406/1324 4700,00 Incl. rotor 1324 Opmerking : bekers en adapters NIET inclusief Deze aanbiedingen zijn niet geldig in combinatie met eventuele andere prijsovereenkomsten van Voor t Labo en zijn uitsluitend bestemd voor eindgebruikers. Prijzen zijn exclusief btw en zijn alleen geldig in België. Producten kunnen verschillen van de afbeeldingen. 2016 Voor t Labo, alle rechten voorbehouden. Onder voorbehoud van vergissingen USP Safety and comfort in the workplace using carriers with a single-hand clamp lock The clamp lock of the 1560 carrier can be operated without difficulty with just one hand. The carrier can be comfortably carried by the clamp whether the lid is in place or not since, in contrast to the products from other manufacturers, the clamp is mounted on the carrier and not on the lid. If the lid is in place, the carrier can not only be carried with ease, it is also safe to transport. 4. With the clamp in the open position the lid can be easily fitted and removed. 5. With the clamp in the central position the carrier is sealed to prevent aerosol formation and can be safely carried to the centrifuge, workbench or another working space. 6. With the clamp in the close position the carrier can be centrifuged without aerosol formation. The absence of aerosols has been verified by the TÜV in accordance with DIN EN 61010, Part 2-020.