. architecten gefocust zijn op het ontwerp van het gebouw,. producenten van gevelbekleding zich richten op de eigenschappen

Vergelijkbare documenten
SMART FIXING SYSTEMS

FRAME [UPRIGHT MODEL] / [DEPTH] / [HEIGHT] / [FINISH] TYPE OF BASEPLATE P Base plate BP80 / E alternatives: ZINC finish in all cases

Mounting ceiling & wall

Constructie-/ kozijnplug SXRL-FUS

AE1103 Statics. 25 January h h. Answer sheets. Last name and initials:

Kabelkanalen - Cable ducts. thermisch verzinkt hot dip galvanized. Scheepsladder H30

Kabelkanalen - Cable ducts. Scheepsladder H30. stainless steel. roestvaststaal

Report for D-Sheet Piling 9.2

Marine ladder H30. Scheepsladder H30. Scheepsladder H30 / Marine ladder H30. Kabelladder, Roestvaststaal. Cable ladder, Stainless steel

REIN kast. eiken standaard iepen. gebakken iepen. gerookt. licht iepen. bijzonderheden. staanders/achterwand/deur. ontwerp: Gjalt Pilat, 2005

Scheepsladder H30 Marine ladder H30

liniled Cast Joint liniled Gietmof liniled Castjoint

VNWall Technische fiche

Marine ladder. Scheepsladder H30 H30. Scheepsladder

AE1103 Statics. 5 November h h. Answer sheets. Last name and initials:

Bijlage 3 D-Sheet Piling factual report voorzetwand t.b.v. promenade

Kabelkanalen Cable ducts Streamline H40/H60

Type-, partij- of serienummer, dan wel een ander identificatiemiddel voor het bouwproduct, zoals voorgeschreven in artikel 11,lid 4: Zie bijlage 1

Thermal Coating implementation project.

Postbus ZN Bleiswijk Brandpuntlaan Zuid NZ Bleiswijk

Flybye. Ernst Koning, Montagehandleiding / Instruction manual

PRESTATIEVERKLARING. Nr NL. bijlages B 1 tot en met B 4

Constructieplug SXR-T

Product Information: Aluminium planters

AE1103 Statics. 3 November h h. Answer sheets. Last name and initials:

Productinformatie 28/09/2007

FIRE PROOF PANELS PAROC. Built-on façade oplossingen. Profielplaat, Cassettes, Hout, Glas, Keramische tegels, Steen

FSB plug-in handles for doors and windows Technical Details

Notitie : In de grond gevormde palen met grondverwijdering

WATERFILTERS HANDMATIG EN DISC-FILTRATIE. Tuinbouwtechniek & -benodigdheden. KaRo BV Tulpenmarkt PK Zwaagdijk

De voordelige bevestiging voor een flexibel gebruik in niet gescheurd beton UITVOERINGEN

Dagelijkse checklist Daily checklist

SPID Azimuth antenna rotator Type: RAK

Het inwendige draadanker met kraag voor een eenvoudige slagmontage UITVOERINGEN. elektrolytisch verzinkt staal roestvast staal BOUWMATERIALEN

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 1

Specification sheets HEMPEL

SPID Azimuth antenna rotator Type: BIG-RAK

NIEUW TYPE Z DIKTE... : GEWICHT... : MATERIAALOPBOUW... : STANDAARDAFMETINGEN... : PERFORATIE... : TOPLAAG... :

SPX Model A-360 Azimuth Antenna Rotor Model 1 & 2

STRUCTURAL CALCULATION Deck beams HxB 40x60

ZB4BA2 kop voor drukknop - Ø 22 - zwart - met kapje

KABELGELEIDING cable guide

LED FLEXIBELE STRIP DIAMOND II SERIE

PRESTATIEVERKLARING. Nr NL. Bevestiging achteraf in ongescheurd beton, zie bijlage, in het bijzonder bijlages B 1 tot en met B 3

Mechanically Actuated Valves

dual black & white collection

PANEELRADIATOR - Type PR Handleiding. PANEL RADIATOR - Type PR Manual

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 1

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 2+

Specification sheets HEMPEL

LED LUMIAFLEX II SERIE

OUTDOOR HD BULLET IP CAMERA PRODUCT MANUAL

PRESTATIEVERKLARING. Nr NL. Bevestiging achteraf in gescheurd of ongescheurd beton, zie bijlage, in het bijzonder bijlages B 1 tot en met B 6

I.S.T.C. Intelligent Saving Temperature Controler

YOUR PARTNER FOR ALL YOUR SELFDRILLING ANCHORS AND STRANDANCHORS

LED LUMIAFLEX II SERIE

Oost-West Legging Zonnepanelen, Study/Motivatie met Calculatie en Berekening K2 D-Dome 2.0 Montage/Opstelling materialen

CLOSED IMPELLER CENTRIFUGAL ELECTRIC PUMPS IN AISI 304. DWC serie. made for your process

Elcee Sanitair BV Korhoenweg RM Klundert

Type-, partij- of serienummer, dan wel een ander identificatiemiddel voor het bouwproduct, zoals voorgeschreven in artikel 11,lid 4: Zie bijlage 1

Create emotions with lighting

open standaard hypertext markup language internetprotocol transmission control protocol internet relay chat office open xml

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 1

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 1

General info on using shopping carts with Ingenico epayments

Constructieplug FUR-T

PRESTATIEVERKLARING. Nr NL. Bevestiging achteraf in gescheurd of ongescheurd beton, zie bijlage, in het bijzonder bijlages B 1 tot en met B 4

Process Mining and audit support within financial services. KPMG IT Advisory 18 June 2014

CTI SUITE TSP DETAILS

2019 SUNEXCHANGE USER GUIDE LAST UPDATED

Remote sensor series

Johto. Flexible light

Van cel naar gevel. Thom Kuipers

Quality requirements concerning the packaging of oak lumber of Houthandel Wijers vof ( )

Architectural Façade Solutions OUTSTANDING QUALITY

FSW-VW-2X2 FSW-VW. Handleiding / Manual

Installatie van Windows 10 op laptops. Windows 10 installation on laptops

Johto. Flexible light

SPX AX-400 Azimuth & Elevation antenna rotator Model 1 & 2

ZB5AA334 kop voor drukknop Ø22 wit pijl naar boven

Contactloos uitlaatafzuigsysteem

PRESTATIEVERKLARING. DoP: voor fischer Doorsteek anker FAZ II (Momentgecontroleerd spreidanker) NL

Zone 1 & zone 2 Zone 21 & zone 22

Bijlage 2: Informatie met betrekking tot goede praktijkvoorbeelden in Londen, het Verenigd Koninkrijk en Queensland

Toepassing van Hoge Sterkte Staal Nieuwegein, 20 april 2017

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 2+

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 1

ATEX serie ATEX range

SHP-TS TwinArc SA SHP-TS 400W TWINARC E40 SL PRODUCT OVERVIEW

MyDHL+ Uw accountnummer(s) delen

LONDEN MET 21 GEVARIEERDE STADSWANDELINGEN 480 PAGINAS WAARDEVOLE INFORMATIE RUIM 300 FOTOS KAARTEN EN PLATTEGRONDEN

Cateringweg 10, Schiphol

6500 confectie richtlijn cover sewing guide Konfektionbeispiel Exemple de confection

Schiphol Boulevard 207 Schiphol Airport

7 Piece Fillet Weld Set

Meetkunde en Lineaire Algebra

BENCHMARK. by Kingspan. Dri-Design Gevelbekledingssysteem. Nederland & België

PRESTATIEVERKLARING. DoP: 0058 voor termoz SV II ecotwist (Kunststof verbindingen voor gebruik in beton en metselwerk ) NL

Activant Prophet 21. Prophet 21 Version 12.0 Upgrade Information

design: BDT enjoy the simplicity CJ 103

Transcriptie:

SYSTEMS THINKING

PHOTO: FELIX FRIEDMANN WAAROM GEVELBEKLEDING MET SMART FIXING SYSTEMS Designmaterialen zoals HPL, vezelcement, terracotta of metaal voldoen aan het verlangen van de architect met betrekking tot kleur, afwerking en vorm Dit alles bevestigd op een aluminium achterconstructiesysteem De mogelijkheden zijn eindeloos! Een intelligent bevestigingssysteem voor geventileerde gevelbekleding gaat alle uitdagingen aan Het moet voorzien in het optimale bevestigingssysteem: voor alle soorten gevelbekledingen en voor alle ontwerp vereisten Tegelijk verwacht men dat het: economisch is, veilig is, en een levenslange presentatie levert Buiten deze eisen, moet het ook voldoen aan: de statische vereisten van het project en de omgeving aansluiten op de locale regelgeving en normen SYSTEMATISCH DENKEN IS ONZE MISSIE TERWIJL architecten gefocust zijn op het ontwerp van het gebouw, producenten van gevelbekleding zich richten op de eigenschappen en de productie, de installateurs aan een efficiënte montage denken Wij het complete pakket van de aluminium achterconstructie in gedachte hebben ALLFACE SUPPORT Gedurende de planning en aanbiedingsperiode, omvat onze service: details van al onze bevestigingssystemen, de ontwikkeling van speciale profielen, gerichte oplossingen voor een optimaal bevestigingssysteem Gedurende de montageperiode, garanderen wij de best mogelijke projectrealisatie van onze producten en diensten door: project specifieke kostencalculatie van de materialen, statische calculaties, structurele analyses, installatietekeningen, veelomvattende trainingen aan installateurs, hoogwaardige kwaliteitsproducten en korte leveringstijden Onze service omvat technische expertise, specifieke kennis van onze kwaliteitsproducten en de flexibiliteit van de leveringen Als systeempartner van de internationale gevelindustrie, blijven we samenwerken met vernieuwende spelers in de markt Ons wereldwijde netwerk helpt ons bij deze marktbenadering Wij bieden de producten en service die gevraagd worden in de markt

DE PLANNINGSPERIODE SYSTEEMDETAILS Voor ieder Allface bevestingssysteem, zijn er systeemdetails beschikbaar Zowel op papier als ook om te downloaden (dwg, dxf, pdf) De details hebben betrekking op de meest belangrijke bouwkundige items zoals, ondergrond, raamkozijnen, hoekoplossingen, etc Bezoek ons op onze Website wwwallfacecom» Download SYSTEEMSUGGESTIES VOOR DE OPTIMALE BEVESTIGING De architect definieert het gevelontwerp in bijvoorbeeld gevelmateriaal, formaat, bevestigingstype en in het zichtbareof onzichtbare bevestigingssysteem Daar waar nodig zullen wij u op professionele wijze adviseren voor het beste bevestigingssysteem Door middel van project specifieke detail- en montagetekeningen CAD- TEKENING, DETAILS VAN EEN STANDAARD ZICHTBARE BEVESTIGING SYSTEEMSPECIFICATIES Om het administratieve werk voor de architect te vereenvoudigen, voorzien wij hen van bestekteksten voor ieder bevestigingssysteem Kijk op: wwwallfacecom» Download ALLFACE System Specifications H92 RAINSCREEN CLADDING 120 RAINSCREEN CLADDING ALLFACE manufacture a range of rainscreen cladding systems Based on F1, F2, F3 and F4 brackets and a range of ALLFACE vertically and horizontally fixed profiles ALLFACE offer a design support service and can provide project specific static calculations, setting out information and AutoCad drawings for the components and rails required to support any chosen system ALLFACE can also provide recommendations System F110 and details of a complete range of rainscreen panels, by a variety of System manufacturers F110 is available and will design for Metal the or fixings ACM and Cladding, supports and utilizes a visible fixing system to suit a chosen panel with rivets (colour coded) Vertical profiles are fixed using F1 support brackets, fixed through a series of fixed and Metal / Aluminium Composite flexible Material points Cladding (ACM) page 2 HPL Cladding / Fibrecement The F1 flexible point bracket absorbs wind loading page and allows 9 for expansion/ contraction The F1 fixed-point bracket absorbs both vertical dead loads and horizontal wind loads Fibre Concrete Cladding Bracket spacing is determined by cladding options page such 15 as the dimensions and weight of Ceramic / Thin Stone Cladding the façade cladding, local wind loads and cladding page zone 21 Consult ALLFACE technical literature for details ALLFACE can also provide a design and specification service and it is recommended that they are consulted early in the design process Rainscreen cladding system: Manufacturer: Allface Smart Fixing Systems GesmbH & CoKG, Aredstrasse 29, A-2544 Leobersdorf, Tel: +43(0)225662518, Fax: +43(0)22566251818, e-mail: office@allfacecom, wwwallfacecom Type: Drained and Ventilated Rainscreen Rainscreen panel: Manufacturer: Consult with ALLFACE for recommendations and details Product reference: System F110 Material: Thickness: Finish/colour: Fasteners: Number and location of fasteners: Consult with ALLFACE Ltd for recommendations and details Joint type: Joint width: Air gap: 25 mm minimum Consult with ALLFACE for recommendations and details Secondary support/framing system: Vertical Manufacturer: ALLFACE as Leobersdorf, above 19102007 Product reference: ALLFACE F110 F1 Brackets Size: Size: 35 mm; 50 mm; 80 mm; 115 mm; 135 mm; Page 1/28 150 mm; 170 mm; 185 mm; 220 mm; 255 mm; + (optional) Allface Isolator ALLFACE L Profile Vertical ALLFACE T Profile Vertical Material: Aluminium to EN AW 6060 T68 Fasteners: Stainless Steel - Consult with ALLFACE for recommendations and details Number and location of fasteners: Consult with ALLFACE for recommendations and details Backing wall: Vapour control layer: Thermal insulation: As clause 776 Breather membrane: Page 5/28

PROJECTREALISATIE OBJECT SPECIFIEKE HOEVEELHEIDS- EN KOSTENCALCULATIE Ons team van engineers staan altijd klaar om onze klanten te assisteren in het maken van een passende offerte Zoals het experts betaamt, zijn zij in staat om het project tot in detail te calculeren De uitkomst van de offerteprijs verschilt maar marginaal van de uiteindelijke prijs, als deze gebaseerd zijn op de uiteindelijke plannen Het definitieve bedrag zal gecalculeerd worden wanneer het contract rond is Projectinformatie en plannen als basis Startpunt voor de ten doelgestelde aantallen en kosten zullen weergegeven worden aan de hand van het invullen van het projectinformatieformulier Samen met de geveltekeningen en details, is het projectformulier de basis voor alle verdere calculaties Het projectformulier is ook verkrijgbaar door het te downloaden op wwwallfacecom» Download HET PROJECTINFORMATIEFORMULIER GEVELTEKENINGEN EN VERTICALE DETAILS

PROJECTREALISATIE Bepaling van een representatief gebied Een representatief gedeelte van de gevel wordt gekozen om het gehele project te vertegenwoordigen tijdens de offertefase Dit dient als basis om het gehele project qua aantallen, structuur en kosten te calculeren Systeemanalyses, definities van het bevestigingssysteem en grafische presentatie dmv een installatieplan Gebaseerd op essentiële projectinformatie, zoals muurcondities, uittrekwaarde van de ankers, type plaatmateriaal, afmetingen, gewicht van panelen, klimaatcondities etc, maken onze engineers de benodigde statische analyse om het bevestigingssysteem te bepalen Vervolgens maken zij een montageschets voor het representatieve projectgebied, welke alle systemencomponenten zoals, profielen, wandsteunen en diverse montageafstanden bevatten Materiaalhoeveelheden en kostencalculatie Het installatieplan laat de exacte aantallen van de systeemeenheden zien, welke nodig zijn voor het representatieve gebied Door het bedrag van het aantal elementen te delen door het aantal vierkante meters, wordt het exacte bedrag per vierkante meter berekend Vervolgens zal de exacte prijs berekend worden voor het complete project De klant hoeft alleen de vierkante meter prijs te vermenigvuldigen met het totaal aantal vierkante meters van het project, voeg hierna de marge en installatiekosten toe REPRESENTATIEF GEBIED EN INSTALLATIEPLAN AANTALLEN EN KOSTEN VOOR EEN ENKELE VIERKANTE METER Offer No AN0800691 Project: Georgetown office, Gardenstreet 18, 984178 Lexington Cladding material: HPL wall condition concrete C25/20 Allface system: F110 insulation thickness 120mm Area in m²: 100 cavity space 150mm HPL panels 8mm thickness, landscape placed wind load centre area +0,62 kn / -0,65 kn wind load corner area +0,62 kn / -0,81 kn The figures/ m² below are results of calculation on partial elevations The overall figures may vary +/-10% No Article No Description Qantity/ Unit Price/U Price/ m² nit m² Insulator pad, suitable for bracket F1, 1 IF1 dimension: 65x90x5mm, material: PVC 2,11 PCS 0,62 1,31 2 F1150D11 3 I+F1 4 F1+150D11 5 D-SKT1000600VZ 6 S-SKT0480190A2 bracket F1, material EN AW 6060T68, 1 fixing hole 22/11mm, height 90mm, depth 150mm Insulator pad, suitable for bracket F1+, dimension:65x175x5mm, material: PVC bracket F1, material EN AW 6060T68, 2 fixing holes 22/11mm, height 175mm, depth 150mm galvanized hexagon head screw, width across flat 13mm, especially for concrete wall self drilling screw 4,8x19 with hexagon head, width across flat 8mm, material A2, 2,11 PCS 2,46 5,19 0,43 PCS 0,74 0,32 0,43 PCS 3,39 1,46 2,97 PCS 0,37 1,10 5,94 PCS 0,22 1,31 7 A-L04006020 L-profile 40/60/2,0mm, material EN AW 6060T68, length 6000 mm 1,89 RM 4,15 7,84 8 A-T10006020 T-profile 100/60/2,0mm, material EN AW 6060T68, legth 6000 mm 0,69 RM 7,07 4,88 Alu/Stainless steel rivet 5,0x18,0mm, 9 N-50180140LAN head 14,00mm, grip range 9-12,5mm, coloured 7,00 PCS 0,38 2,66 TOTAL / m2 26,06

-0,16 PROJECTREALISATIE STATISCHE ANALYSE Regelmatig worden onze technici gevraagd om een statische analyse op te stellen Deze is nodig voor de verschillende instanties en voor het vaststellen van de veiligheid bij publieke gebouwen Bouwkundige analyses, waarbij gekeken wordt naar de veiligheid van het bevestigingssysteem, zijn zeer uitgebreid Daarom worden deze alleen verstrekt na aanvraag van de klant en hiervoor zullen kosten worden berekend De statische analyse is gebaseerd op de basis statistieken van het gekozen bevestigingssysteem, hierbij moet rekening gehouden worden met: alle variabelen die invloed kunnen hebben op de impact van het project, zoals wind, ondergrond, formaat, gewicht van het gevelelement, etc zullen in de kosten meegenomen worden De relevante landelijke wet- en regelgeving DETAIL VAN EEN BOUWKUNDIGE ANALYSE REKENING HOUDEND MET DE AFWIJKING VAN DE ONDERSTEUNENDE L- EN C- PROFIELEN project: Georgetown Office, Center Area project: Georgetown Office, Center Area standard: IBC 2003 + DIN 4113 results: system: vertical supporting profile L-60/40/1,6 (stark) material: EN AW 6060T68 E= 7000 kn/cm² srk= 20,0 kn/cm² / ym= 2,00 srd= 10,0 kn/cm² geometric data: limit of defection: L/ 300 numb of spans: 3 horizontal: effect width of wind: 58 cm 22,83 inch effect width of dead load: 58 cm 22,83 inch wind load reactions: diagrams of moment, deflexion and shear force Momentenlinie <knm> -0,01, 0,01 0,02 Durchbiegung / Deflexion <mm> -0,03-0,03 0,02-0,01 vertical: length of profile: 296 cm 116,54 inch -0,112 0 0000 0220 0,220 0085 0,085 0221 0,221-0,113 25 cm 82 cm 82 cm 82 cm 0 cm25 cm 0,16 0,18 0,19 0,11 * safety factor: * correction loads/actions: charakt load: yg; yq factor = design load wind suction: (absolut) 0,75 kn/m² 1,00 1,00 = 0,75 kn/m² wind pressure: (absolut) 0,69 kn/m² 1,00 1,00 = 0,69 kn/m² dead load: 0,18 kn/m² 1,00 1,00 = 0,18 kn/m² -0,11-0,19 dead load reaction: diagrams of moments and deflexion: -0,18 wind load; max( suction; pressure) : 0,44 0,44 0,44 0,44 0,44 25 cm 82 cm 82 cm 82 cm 0 cm 25 cm dead load: 0 0 0 0 0 0 kn/m kn/m kn/m kn/m kn/m 25 cm 82 cm 82 cm 82 cm 0 cm 25 cm for profile: stress ratio due to wind suction: L-60/40/1,6 (stark) 22,31% stress ratio due to wind pressure: 26,29% bearing loads: due to wind suction: H: 0,27 kn H: 0,37 kn H: 0,37 kn H: 0,27 kn dt wind pressure: H: 0,25 kn H: 0,34 kn H: 0,34 kn H: 0,25 kn due to dead load: V: kn V: 0,31 kn V: kn V: kn the brackets have to be dimensioned separatly

PROJECTREALISATIE INSTALLATIETEKENINGEN Installatietekeningen worden aangeboden op verzoek van de klant en zijn een nauwkeurige basis voor de efficiënte installatie en een betrouwbare project implementatie Tevens kunnen eventuele fouten in de tekeningen vroegtijdig worden ontdekt en correcties aangebracht worden nog voor er begonnen wordt met de installatie De tekeningen zijn erg kostbaar en ook niet kosteloos Deze zullen op verzoek van de klant aangeboden worden De plannen, getekend door Allface, worden gerefereerd aan de afmetingen in de tekening, natuurlijke afmetingen kunnen hierin niet worden verenigd INSTALLATIEPLAN

PHOTO: OTTO HAINZL WWWAUGMENTAT CFS Nederland Bredaseweg 108a, 4902 NS Oosterhout T +31 (0)162/452 086 F +31 (0)162/421 591 e info@cfsnederlandnl wwwcfsnederlandnl ALLFACE Befestigungstechnologie GmbH & CoKG A 2544 Leobersdorf, Aredstraße 29 Büro 222 T +43(0)2256/625 18 F +43(0)2256/625 18 18 e office@allfacecom wwwallfacecom