1 Uitbreidingsmodule NX-0/NX-0 NX-0/NX-0 Uitgangsmodule Installatiehandleiding Oktober 00 NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

2 Uitbreidingsmodule NX-0/NX-0 INHOUDSOPGAVE. ALGEMENE BESCHRIJVING.... INSTALLATIE VAN DE NX-0/NX MONTAGE IN DE KAST.... BESCHRIJVING AANSLUITKLEMMEN NX LAYOUT NX-0 PRINT.... BESCHRIJVING AANSLUITKLEMMEN NX LAYOUT NX-0 PRINT.... REGISTRATIE EN BEWAKING VAN DE NX-0/NX PROGRAMMERING VAN NX-0/NX-0 UITGANGSMODULE OMSCHRIJVING VAN DE GEHEUGENADRESSEN.... PROGRAMMEERVOORBEELDEN.... NX-0/NX-0 PROGRAMMEERBLADEN.... TECHNISCHE SPECIFICATIES... 0 NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

3 Uitbreidingsmodule NX-0/NX-0. Algemene beschrijving De NX-0/NX-0 zijn microprocessor-gestuurde uitgangsmodules die aangesloten kunnen worden op alle centrales. De NX-0 heeft relaisuitgangen en open colector uitgang. De NX-0 heeft open collector uitgangen. Er kunnen maximaal acht NX-0/ NX-0 modules op een bus aangesloten worden, waardoor max. open collectoren (NX-0) of relais (NX-0) aangestuurd kunnen worden. Elke NX-0/ NX-0 module heeft een sabotage schakelaar en een Volt voedingsuitgang (zie beschrijving aansluitklemmen), waardoor de NX-0/NX-0 uitermate geschikt is om op afstand geplaatst te worden.. Installatie van de NX-0/NX-0 Het eerste wat bepaald dient te worden is het specifieke nummer van de betreffende uitgangs-module. Het module nummer zal eveneens gespecificeerd dienen te worden wanneer men de NX-0/NX-0 module wenst te programmeren. Het juiste nummer kan ingesteld worden m.b.v. onderstaande tabel. DIP schakelaar : Aan/uitzetten van de sabotage schakelaar en TAM-klem van de NX-0/NX-0 ( ON = AAN, OFF = UIT). Modulenummer Dip schakelaar Dip schakelaar Dip schakelaar ON ON OFF OFF OFF ON ON OFF ON OFF ON ON ON ON ON 9 OFF OFF OFF 0 ON OFF OFF OFF ON OFF. Montage in de kast Binnenin de kast zijn er verschillende montagepunten (met gaten) voorzien. Hierdoor kunnen de modules zowel horizontaal als verticaal gemonteerd worden. = Noot: ieder montagepunt is voorzien van soorten gaten: een groter gat en een kleiner gat. Figuur : De plastieken printgeleiders (steuntjes) zijn aan één zijde voorzien van een gleuf waarin de print kan geschoven worden. Het uiteinde met het halfmaanvormige uitsteeksel past in het grootste gat. Het kleinste gat is voor de bevestigings-schroef. Figuur : Plaats het eerste zwarte steuntje in het bovenste bevestigingspunt, met de gleuf naar beneden gericht. Het halfmaanvormige uitsteekstel dient in het grootste gat geplaatst te worden. Hiervoor dient men geen kracht te gebruiken. Plaatst één van de meegeleverde schroeven in het kleinste gat (vanaf de binnenzijde van de kast) om het steuntje te fixeren. Via de inkeping kan men het steuntje vastzetten met een schroeven-draaier die voldoende lang is. Het tweede steuntje dient recht tegenover het eerste steuntje geplaatst te worden (met gleuf naar boven gericht). Dit steuntje dient op dezelfde manier als het eerste gefixeerd te worden. Figuur : de print kan nu in de gleuven van beide steunen geschoven worden. NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

4 Uitbreidingsmodule NX-0/NX-0. Beschrijving aansluitklemmen NX-0 KLEM DATA COM POS TAM COM AUX Relais Relais - J OMSCHRIJVING Te verbinden met de Data klem van de alarmcentrale. Via deze klem wordt signaaldata over de bus verstuurd. Te verbinden met de COMMON klem van de alarmcentrale. Deze klem levert het negatief van de voeding voor de NX-0 module. Te verbinden met de AUX POWER + klem van de alarmcentrale. Deze klem levert de positief van de voeding voor de NX-0 module. Dit is een optionele sabotage-aansluitklem. Om deze klem te kunnen gebruiken, dient een normaal gesloten (NC) contact aangesloten te worden tussen deze klem en de COM klem (bijv. sabotagecontact van behuizing). Als deze klem niet gebruikt wordt, dan dient er deze klem kortgesloten te worden met de COM klem. Te verbinden met de TAM klem via een normaal gesloten (NC) contact. Aparte beveiligde spanningsuitgang van Vdc max. 00 ma. NOOT:Elk stroomverbruik vanaf deze klem dient bij de totale stroomafname van de NX- of NX-0 geteld te worden. Via deze klem kan de voedingsspanning tussen de centrale en de op afstand geïnstalleerde toestellen geïsoleerd worden. Wanneer een kortsluiting optreedt op de AUX klem, dan zullen alle toestellen die vanuit deze klem gevoed worden niet meer functioneren maar alle andere toestellen, inclusief de NX-0, zullen normaal blijven functioneren. De NX-0 zal een overstroomfout rapporteren aan de centrale. Deze fout zal op de bediendelen als overstroom uitbreiding getoond worden. Relais is relais met wisselcontact. NC Normaal gesloten relais.schakelvermogen: A/0Vdc COM NO Normaal geopend relais. Schakelvermogen: A/0Vdc Te verbinden zoals beschreven voor relais. Uitgang programmeerbaar Open Collector uitgang: max. 00 ma. min gestuurd. Layout NX-0 print NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

5 Uitbreidingsmodule NX-0/NX-0. Beschrijving aansluitklemmen NX-0 KLEM DATA COM POS TAM COM AUX Out - OMSCHRIJVING Te verbinden met de Data klem van de alarmcentrale. Via deze klem wordt signaaldata over de bus verstuurd. Te verbinden met de COMMON klem van de alarmcentrale. Deze klem levert het negatief van de voeding voor de NX-0 module. Te verbinden met de AUX POWER + klem van de alarmcentrale. Deze klem levert het positief van de voeding voor de NX-0 module. Dit is een optionele sabotage-aansluitklem. Om deze klem te kunnen gebruiken, dient een normaal gesloten (NC) contact aangesloten te worden tussen deze klem en de COM klem (bijv. sabotagecontact van behuizing). Als deze klem niet gebruikt wordt, dan dient er deze klem kortgesloten te worden met de COM klem. Te verbinden met de TAM klem via een normaal gesloten (NC) contact. Aparte beveiligde spanningsuitgang van Vdc max. 00 ma. NOOT:Elk stroomverbruik vanaf deze klem dient bij de totale stroomafname van de NX- of NX-0 geteld te worden. Via deze klem kan de voedingsspanning tussen de centrale en de op afstand geïnstalleerde toestellen geïsoleerd worden. Wanneer een kortsluiting optreedt op de AUX klem, dan zullen alle toestellen die vanuit deze klem gevoed worden niet meer functioneren maar alle andere toestellen, inclusief de NX-0, zullen normaal blijven functioneren. De NX-0 zal een overstroomfout rapporteren aan de centrale. Deze fout zal op de bediendelen als overstroom uitbreiding getoond worden. Open Collector uitgangen: max. 00 ma. min gestuurd. Layout NX-0 print NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

6 Uitbreidingsmodule NX-0/NX-0. Registratie en bewaking van de NX-0/NX-0 Ten einde de aangesloten modules te kunnen bewaken, detecteert de centrale automatisch de aanwezigheid van alle aangesloten bediendelen, zone-uitbreidingen, draadloze ontvangers, uitgangsmodules, enz. en registreert het adres ervan in het systeemgeheugen. Op die manier kunnen alle modules bewaakt worden door de centrale. De modules kunnen geregistreerd worden door de programmeerstand van de centrale te activeren.indien gewenst, kan men de programmering van de centrale of een bepaalde module nog aanpassen. Bij het verlaten van de programmeermode zal de centrale automatisch alle aangesloten modules (inclusief bediendelen) registreren. Dit identificatieproces duurt ongeveer seconden en wordt weergegeven door een Service indicatie. Als een geregistreerde module door de centrale niet meer gedetecteerd wordt, dan zal na een bepaalde tijd een Service indicatie weergegeven worden. 9. Programmering van NX-0/NX-0 uitgangsmodule Lees eerst de programmeerhandleiding hoe de procedures zijn om te programmeren Stap in de programmeerstand zoals beschreven in programmeerhandleiding. Toets [ ] in en daarna de installateurscode (standaard 9). Geef hierna het modulenummer in welke geprogrammeerd worden. Dit kan nummer t/m zijn voor de (relais-)uitgangsmodule NX-0/NX-0. Programmeer hierna de adressen van de (relais-)uitgangsmodule zoals beschreven staat in het volgende hoofdstuk. De programmeerstand kan verlaten worden met de [Afwezig] toets. Hiermee verlaat men de geselecteerde module en bereikt men het selecteer te programmeren module niveau. Als er geen bijkomende modules dienen geprogrammeerd te worden, kan men door nogmaals op de [Afwezig] toets te drukken de programmeermode verlaten. Als er nog een bijkomende module dient geprogrammeerd te worden, dan kan deze geselecteerd worden door het corresponderende modulenummer in te voeren gevolgd door [#] OPMERKING: Als er binnen de minuten geen toetsaanslag gebeurt, zal de programmeermode automatisch verlaten worden. NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

7 Uitbreidingsmodule NX-0/NX-0 0. Omschrijving van de geheugenadressen ADRES 0 GEBEURTENIS, GEBRUIKER/ZONE ACTIVATIETIJD VOOR UITGANG ( segmenten, numerieke data) Segment - Gebeurtenis Bepaalt door welke gebeurtenis de uitgang aangestuurd zal worden. Zie onderstaande tabel voor alle mogelijke gebeurtenissen. Deze tabel geeft voor elke gebeurtenis het bijhorende nummer dat geprogrammeerd moet worden. Nr. Gebeurtenis Nr. Gebeurtenis Nr. Gebeurtenis 09 Inbraakalarm 0 Aankomst-of 0 Sabotage behuizing vertrektijd actief 9 Brandalarm Ingeschakeld Sabotage sirene 9 uur alarm Uitgeschakeld Elke zoneverstoring 9 Storing (brand/dagz.) Gereed 9 Elk alarm 9 Zonesabotage Niet gereed Bediendeelzoemer actief Inbraaksirene Brandalarm 9 Code-ingave Brandsirene Brandstoring Sleutelhanger functie Elke sirene Deurbel Sleutelhanger functie Zoneblokkering 9 Storing uitbreiding Automatisch inschakelen 9 Netfout 9 Actieve accutest bezig 9 Automatisch uitschakelen 0 Accufout 0 Openingsperiode 0 Automatisch in- en uitschakelen 9 Gedwongen in/uit Sluitingsperiode Volg tijdrooster van NX-0 9 Handmatig brandalarm Inluistering Knipperende X-0 voor alarmgeheugen 9 Handmatig medisch alarm Kiezer actief Knipperende X-0 voor sirene 9 Handmatig paniekalarm Communicatiefout Ingeschakelde toestand nadat vertrektijd voorbij is Blokkering codebediening Telefoonlijnfout Einde inluistering 9 Automatische test Programmeerstand Aansturing via NX- Alarmgeheugen Download bezig Volg zone bij niet in alarm Aankomsttijd actief Volg zonetoestand in Service led alarm 9 Vertrektijd actief 9 Overstroom Vdc 9 In aanwezig status 9 Indien ingesteld om de gebeurtenis te volgen (segment ), dan zal de activeringstijd seconde bedragen Zie adressen en in installatiehandleiding van centrale. Om te kunnen werken vereisen gebeurtenissen en een draadloze ontvanger type NX-0-I, NX--I of NX-. Gebeurtenissen, 9 en 0 zullen de NX- centrale in- of uitschakelen op het geprogrammeerde inschakel- of uitschakeltijdstip van het betreffende tijdrooster. Zie voorbeeld op pagina. Segment - Zone/gebruiker Hier wordt bepaald door welke zone of gebruiker de uitgang aangestuurd zal worden. Als op dit segment een nul ( 0 ) geprogrammeerd wordt, dan zal deze uitgang actief zijn voor elke zone of elke gebruiker (zie ook: adres ). Segment - Activeringstijd Bepaalt hoelang deze uitgang geactiveerd zal worden, wanneer de geprogrammeerde gebeurtenis optreedt. Als in dit segment een nul ( 0 ) geprogrammeerd wordt, dan zal deze uitgang de betreffende gebeurtenis volgen. NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

8 Uitbreidingsmodule NX-0/NX-0 ADRES SPECIALE FUNCTIES PARTITIES VOOR UITGANG ( segmenten, optie-data) Segment - selecteert de volgende speciale opties: Aan : Uitgang wordt gestuurd in minuten; Uit : Uitgang wordt gestuurd in seconden Aan : Uitgang wordt gedeactiveerd na code-ingave; Uit : Uitgang is tijdsgestuurd Aan : Uitgang tijdens tijdsduur te deactiveren door code-ingave; Uit : Uitgang blijft tijdsgestuurd na code-ingave Aan : Uitgang alleen activief tijdens sluitingsperiode (= tussen sluitings -en openingstijd van rooster) Aan : Uitgang alleen actief tijdens openingsperiode (= tussen openings -en sluitingstijd van rooster) Aan : Uitgang wordt geïnverteerd (van 0 Volt naar Volt bij activering) Aan : Aansturing dient weggeschreven te worden in logboek. Zie tabel. Module Uitgang nr Segment - selectie van partities: Aan : Uitgang activief als de gebeurtenis optreedt in partitie Aan : Uitgang activief als de gebeurtenis optreedt in partitie Aan : Uitgang activief als de gebeurtenis optreedt in partitie Aan : Uitgang activief als de gebeurtenis optreedt in partitie Aan : Uitgang activief als de gebeurtenis optreedt in partitie Aan : Uitgang activief als de gebeurtenis optreedt in partitie Aan : Uitgang activief als de gebeurtenis optreedt in partitie Aan : Uitgang activief als de gebeurtenis optreedt in partitie ADRES ACTIVERING VAN TIJDROOSTERS VOOR UITGANG ( segment, optie-data) Adres wordt gebruikt om elk van de acht () tijdroosters te activeren. Optie komt overeen met tijdrooster (zie adressen -) en optie komt overeen met tijdrooster (zie adressen -). Dit adres kan gebruikt worden in combinatie met het adres voor de speciale functies (adres,optie en ) om een uitgang te programmeren die enkel zal activeren tijdens bepaalde tijdsintervallen en/of op bepaalde dagen. Aan Aan Aan Aan Aan Aan Aan Aan : de gebeurtenis dient tijdrooster te volgen. : de gebeurtenis dient tijdrooster te volgen. : de gebeurtenis dient tijdrooster te volgen. : de gebeurtenis dient tijdrooster te volgen. : de gebeurtenis dient tijdrooster te volgen. : de gebeurtenis dient tijdrooster te volgen. : de gebeurtenis dient tijdrooster te volgen. : de gebeurtenis dient tijdrooster te volgen. ADRES X-0 ADRES VOOR UITGANG ( segmenten, numerieke data) Segment - Modulenummer Programmeer een getal tussen 0 en om het corresponderende X-0 modulenummer in te stellen. Maak hierbij gebruik van de onderstaande tabel. Module 9 0 Seg Segment - Huiscode Programmeer een getal tussen 0 en om de corresponderende huiscode in te stellen. Maak hierbij gebruik van de onderstaande tabel. X-0 Adrescode 0=A =B =C =D =E =F =G =H huiscode =I 9=J 0=K =L =M =N =O =P NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

9 Uitbreidingsmodule NX-0/NX-0 ADRESSEN - PROGRAMMERING VOOR UITGANGEN - De adressen - worden gebruikt om de gebeurtenissen, de zones/gebruikers, de tijdsinstellingen alsook de speciale functies, de partities, de tijdroosters en de X-0 adressen te programmeren voor uitgangen -. Voor iedere uitgang zijn er adressen voorzien, die op dezelfde manier dienen geprogrammeerd te worden als de adressen voor uitgang (beschreven hierboven, adressen 0 - ). ADRES OPENINGSTIJD VOOR TIJDROOSTER ( segmenten, numerieke data) Segment Segment Het uur van de openingstijd in -uur formaat ( uur middags=) Aantal minuten (na het uur) van de openingstijd. ADRES SLUITINGSTIJD VOOR TIJDROOSTER ( segmenten, numerieke data) Segment Het uur van de sluitingstijd in -uur formaat ( uur middags = ) Segment Het aantal minuten(na het uur) van de sluitingstijd ADRES DE DAGEN VAN TIJDROOSTER ( segment, optie-data) LED Omschrijving Aan : als het tijdrooster actief dient te zijn op zondag Aan : als het tijdrooster actief dient te zijn op maandag Aan : als het tijdrooster actief dient te zijn op dinsdag Aan : als het tijdrooster actief dient te zijn op woensdag Aan : als het tijdrooster actief dient te zijn op donderdag Aan : als het tijdrooster actief dient te zijn op vrijdag Aan : als het tijdrooster actief dient te zijn op zaterdag Aan : als het tijdrooster niet actief dient te zijn op vakantiedagen ADRESSEN - PROGRAMMERING VAN TIJDROOSTERS - De adressen - worden gebruikt om de openingstijden, sluitingstijden en dagen voor tijdroosters - te programmeren. Per tijdrooster zijn er adressen voorzien, die op dezelfde manier dienen geprogrammeerd te worden als de adressen voor tijdrooster (beschreven hierboven, adressen - ). ADRES VAKANTIEDAGEN IN JANUARI ( segmenten, numerieke data) Programmeer de dagen van de maand (in januari) gedurende dewelke de openingstijd onderdrukt dient te worden. Bijvoorbeeld: Als de opening niet dient te gebeuren op januari, dan moet u een programmeren in segment. Deze eigenschap kan herhaald worden voor maximaal vakantiedagen per adres (maand). ADRESSEN - : PROGRAMMERING VAN VAKANTIEDAGEN VAN FEBRUARI TOT DECEMBER ( segmenten, numerieke data) De adressen - worden gebruikt om de dagen van iedere maand (van februari tot december) te programmeren, gedurende welke de openingstijd in een tijdrooster onderdrukt dient te worden. Elk adres kan maximaal vakantiedagen bevatten en wordt op dezelfde wijze geprogrammeerd als beschreven voor adres. NP Data and design are subject to change without notice / Supply subject to availability 9 Copyright - Details as per general conditions of supply, 99

10 Uitbreidingsmodule NX-0/NX-0 ADRES AUTORISATIE VOOR GEBRUIKERS - 0 OM UITGANGEN - TE STUREN (0 segmenten, optie-data) Wanneer uitgangen geactiveerd worden m.b.v. een gebruikerscode (gebeurtenisnummer ), dan kan adres gebruikt worden om voor bepaalde codes de activering van bepaalde uitgangen te verhinderen. Adres bevat 0 segmenten. Segment correspondeert met gebruiker, Segment 0 correspondeert met gebruiker 0. De LED s corresponderen met uitgangen -. NOOT: De zone/gebruiker-specificatie voor de betreffende uitgang dient op 0 ingesteld te worden om dit adres te kunnen gebruiken. LED Omschrijving Aan : als code uitgang zal activeren; Aan : als code uitgang zal activeren; Aan : als code uitgang zal activeren; Aan : als code uitgang zal activeren; Aan : als code uitgang zal activeren; Aan : als code uitgang zal activeren; Aan : als code uitgang zal activeren; Aan : als code uitgang zal activeren; ADRES 9 AUTORISATIE VOOR GEBRUIKERS - 0 OM UITGANGEN - TE STUREN (0 segmenten, optie-data) Zie adres. Segment correspondeert met gebruiker, Segment 0 correspondeert met gebruiker 0. ADRES 0 AUTORISATIE VOOR GEBRUIKERS - 0 OM UITGANGEN - TE STUREN (0 segmenten, optie-data) Zie adres. Segment correspondeert met gebruiker, Segment 0 correspondeert met gebruiker 0. ADRES AUTORISATIE VOOR GEBRUIKERS - 0 OM UITGANGEN - TE STUREN (0 segmenten, optie-data) Zie adres. Segment correspondeert met gebruiker, Segment 0 correspondeert met gebruiker 0. ADRES AUTORISATIE VOOR GEBRUIKERS - 0 OM UITGANGEN - TE STUREN (0 segmenten, optie-data) Zie adres. Segment correspondeert met gebruiker, Segment 0 correspondeert met gebruiker 0. ADRES AUTORISATIE VOOR GEBRUIKERS - 0 OM UITGANGEN - TE STUREN (0 segmenten, optie-data) Zie adres. Segment correspondeert met gebruiker, Segment 0 correspondeert met gebruiker 0. NP Data and design are subject to change without notice / Supply subject to availability 0 Copyright - Details as per general conditions of supply, 99

11 Uitbreidingsmodule NX-0/NX-0 ADRES AUTORISATIE VOOR GEBRUIKERS - 0 OM UITGANGEN - TE STUREN (0 segmenten, optie-data) Zie adres. Segment correspondeert met gebruiker, Segment 0 correspondeert met gebruiker 0. ADRES AUTORISATIE VOOR GEBRUIKERS - 0 OM UITGANGEN - TE STUREN (0 segmenten, optie-data) Zie adres. Segment correspondeert met gebruiker, Segment 0 correspondeert met gebruiker 0. ADRES AUTORISATIE VOOR GEBRUIKERS - 90 OM UITGANGEN - TE STUREN (0 segmenten, optie-data) Zie adres. Segment correspondeert met gebruiker, Segment 0 correspondeert met gebruiker 90. ADRES AUTORISATIE VOOR GEBRUIKERS 9-99 OM UITGANGEN - TE STUREN (9 segmenten, optie-data) Zie adres. Segment correspondeert met gebruiker 9, Segment 9 correspondeert met gebruiker 99. NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

12 Uitbreidingsmodule NX-0/NX-0. Programmeervoorbeelden Mogelijke toepassingen voor uitgangen: Voorbeeld : schakel de aankomstverlichting aan tijdens het binnenkomen, alleen s nachts. Voorbeeld : schakel een toestel in en uit, tijdens de kantooruren. Voorbeeld : schakel het beveiligingssysteem in. NOOT BIJ VOORBEELD : de openingstijd wordt standaard ingesteld op 0.00 u voor alle tijdroosters.in dit voorbeeld zal de NX-0/NX-0 proberen om het systeem automatisch in te schakelen telkens na minuten inactiviteit (op GEREED Led), en dit vanaf de sluitingstijd tot de openingstijd. De eigenschappen die dienen geprogrammeerd te worden, worden weergegeven in schuine vette tekst. Voorbeeld # Om uitgang te activeren en een X-0 module aan te sturen met huiscode C en modulecode, gedurende minuten wanneer zone verstoord wordt. Alleen vanaf h00 tot 09h00. Programmeer het volgende: Voorbeeld # Om uitgang te activeren en een X-0 module aan te sturen met huiscode P en modulecode, vanaf 09h00 tot h00, vanaf maandag tot vrijdag maar niet op zaterdag en zondag. Programmeer het volgende: Voorbeeld # Om via uitgang partities en automatisch in te schakelen om 9h00, vanaf maandag tot vrijdag; om h00 op zaterdag en niet op zondag. Programmeer het volgende: Adres Segment Adres Segment Adres Segment NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

13 Uitbreidingsmodule NX-0/NX-0. NX-0/NX-0 Programmeerbladen (standaardwaarden worden weergegeven in schuine vette tekst) ADRES PAG OMSCHRIJVING STANDAARD DATA 0 Uitgang Gebeurtenis, Zone/Gebruiker, Tijd 0 _ Uitgang Speciale Functies, Partitie (Omcirkel nr. van gewenste opties) Segment Segment Uitgang Tijdrooster "Aan": uitgang gestuurd in minuten; "Uit": uitgang gestuurd in seconden. "Aan": latch uitgang (gestuurd tot code-ingave). "Aan": uitgang tijdens tijdsduur te deactiveren diir code-ingave. sluitingsperiode. openingsperiode. "Aan": uitgang geïnverteerd. "Aan": Gebeurtenis weggeschreven in logboek. Partitie Partitie Partitie Partitie Partitie Partitie Partitie Partitie Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Uitgang X-0 Adres Segment Module Nummer 0 Segment Huiscode 0 X-0 ADRES CODES 0=A =E =I =M =B =F 9=J =N =C =G 0K =O =D =H =L =P 9 Uitgang Gebeurtenis, Zone/gebruiker, Tijd 0 _ 9 Uitgang Speciale Functies, Partitie (Omcirkel nummers van gewenste opties) Segment Segment 9 Uitgang Tijdrooster "Aan": uitgang gestuurd in minuten; "Uit": uitgang gestuurd in seconden. "Aan": latch uitgang (gestuurd tot code-ingave). "Aan": uitgang tijdsgestuurd of gedesactiveerd bij code-ingave. sluitingsperiode. openingsperiode. "Aan": uitgang geïnverteerd. "Aan": Gebeurtenis weggeschreven in logboek. Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Partitie Partitie Partitie Partitie Partitie Partitie Partitie Partitie 9 Uitgang X-0 Adres Segment Module Nummer Segment Huiscode (Zie tabel adres ) 0 NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

14 Uitbreidingsmodule NX-0/NX-0 9 Uitgang Gebeurtenis, Zone/gebruiker, Tijd 0 _ 9 9 Uitgang Speciale Functies, Partitie (Omcirkel nummers van gewenste opties) Segment Segment 0 9 Uitgang Tijdrooster "Aan": uitgang gestuurd in minuten; "Uit": uitgang gestuurd in seconden. "Aan": latch uitgang (gestuurd tot code-ingave). "Aan": uitgang tijdsgestuurd of gedesactiveerd bij code-ingave. sluitingsperiode. openingsperiode. "Aan": uitgang geïnverteerd. "Aan": Gebeurtenis weggeschreven in logboek. Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Partitie Partitie Partitie Partitie Partitie Partitie Partitie Partitie 9 Uitgang X-0 Adres Segment Module Nummer Segment Huiscode (Zie tabel adres) 0 9 Uitgang Gebeurtenis, Zone/gebruiker, Tijd 0 _ 9 Uitgang Speciale Functies, Partitie (Omcirkel nummers van gewenste opties) Segment Segment 9 Uitgang Tijdrooster "Aan": uitgang gestuurd in minuten; "Uit": uitgang gestuurd in seconden. "Aan": latch uitgang (gestuurd tot code-ingave). "Aan": uitgang tijdsgestuurd of gedesactiveerd bij code-ingave. sluitingsperiode. openingsperiode. "Aan": uitgang geïnverteerd. "Aan": Gebeurtenis weggeschreven in logboek. Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Partitie Partitie Partitie Partitie Partitie Partitie Partitie Partitie 9 Uitgang X-0 Adres Segment Module Nummer Segment Huiscode (Zie tabel op pagina 9) 0 NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

15 Uitbreidingsmodule NX-0/NX-0 9 Uitgang Gebeurtenis, Zone/gebruiker, Tijd 0 _ 9 Uitgang Speciale Functies, Partitie (Omcirkel nummers van gewenste opties) Segment Segment 9 Uitgang Tijdrooster "Aan": uitgang gestuurd in minuten; "Uit": uitgang gestuurd in seconden. "Aan": latch uitgang (gestuurd tot code-ingave). "Aan": uitgang tijdsgestuurd of gedesactiveerd bij code-ingave. sluitingsperiode. openingsperiode. "Aan": uitgang geïnverteerd. "Aan": Gebeurtenis weggeschreven in logboek. Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Partitie Partitie Partitie Partitie Partitie Partitie Partitie Partitie 9 9 Uitgang X-0 Adres Segment Module Nummer Segment Huiscode (Zie tabel op pagina 9) Uitgang Gebeurtenis, Zone/gebruiker, Tijd 0 _ 9 Uitgang Speciale Functies, Partitie (Omcirkel nummers van gewenste opties) Segment Segment 9 Uitgang Tijdrooster "Aan": uitgang gestuurd in minuten; "Uit": uitgang gestuurd in seconden. "Aan": latch uitgang (gestuurd tot code-ingave). "Aan": uitgang tijdsgestuurd of gedesactiveerd bij code-ingave. sluitingsperiode. openingsperiode. "Aan": uitgang geïnverteerd. "Aan": Gebeurtenis weggeschreven in logboek. Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Partitie Partitie Partitie Partitie Partitie Partitie Partitie Partitie 9 Uitgang X-0 Adres Segment Module Nummer Segment Huiscode (Zie tabel op pagina 9) 0 NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

16 Uitbreidingsmodule NX-0/NX-0 9 Uitgang Gebeurtenis, Zone/gebruiker, Tijd 0 _ 9 Uitgang Speciale Functies, Partitie (Omcirkel nummers van gewenste opties) Segment Segment 9 Uitgang Tijdrooster "Aan": uitgang gestuurd in minuten; "Uit": uitgang gestuurd in seconden. "Aan": latch uitgang (gestuurd tot code-ingave). "Aan": uitgang tijdsgestuurd of gedesactiveerd bij code-ingave. sluitingsperiode. openingsperiode. "Aan": uitgang geïnverteerd. "Aan": Gebeurtenis weggeschreven in logboek. Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Partitie Partitie Partitie Partitie Partitie Partitie Partitie Partitie 9 Uitgang X-0 Adres Segment Module Nummer Segment Huiscode (Zie tabel op pagina 9) 0 9 Uitgang Gebeurtenis, Zone/gebruiker, Tijd 0 _ 9 9 Uitgang Speciale Functies, Partitie (Omcirkel nummers van gewenste opties) Segment Segment 0 9 Uitgang Tijdrooster "Aan": uitgang gestuurd in minuten; "Uit": uitgang gestuurd in seconden. "Aan": latch uitgang (gestuurd tot code-ingave). "Aan": uitgang tijdsgestuurd of gedesactiveerd bij code-ingave. sluitingsperiode. openingsperiode. "Aan": uitgang geïnverteerd. "Aan": Gebeurtenis weggeschreven in logboek. Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Tijdrooster Partitie Partitie Partitie Partitie Partitie Partitie Partitie Partitie 9 Uitgang X-0 Adres Segment Module Nummer Segment Huiscode (Zie tabel op pagina 9) 0 NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99

17 Uitbreidingsmodule NX-0/NX-0 9 Tijdrooster Openingstijd Tijdrooster Sluitingstijd Tijdrooster Dagen (Omcirkel nummers van gewenste opties) Zondag Maandag Dinsdag Woensdag Donderdag Vrijdag Zaterdag Gedeactiveerd tijdens vakantiedagen 9 Tijdrooster Openingstijd Tijdrooster Sluitingstijd Tijdrooster Dagen (Omcirkel nummers van gewenste opties) Zondag Maandag Dinsdag Woensdag Donderdag Vrijdag Zaterdag Gedeactiveerd tijdens vakantiedagen 9 Tijdrooster Openingstijd Tijdrooster Sluitingstijd Tijdrooster Dagen (Omcirkel nummers van gewenste opties) Zondag Maandag Dinsdag Woensdag Donderdag Vrijdag Zaterdag Gedeactiveerd tijdens vakantiedagen 9 Tijdrooster Openingstijd Tijdrooster Sluitingstijd Tijdrooster Dagen (Omcirkel nummers van gewenste opties) Zondag Maandag Dinsdag Woensdag Donderdag Vrijdag Zaterdag Gedeactiveerd tijdens vakantiedagen 9 Tijdrooster Openingstijd Tijdrooster Sluitingstijd Tijdrooster Dagen (Omcirkel nummers van gewenste opties) Zondag Maandag Dinsdag Woensdag Donderdag Vrijdag Zaterdag Gedeactiveerd tijdens vakantiedagen 9 Tijdrooster Openingstijd Tijdrooster Sluitingstijd Tijdrooster Dagen (Omcirkel nummers van gewenste opties) Zondag Maandag Dinsdag Woensdag Donderdag Vrijdag Zaterdag Gedeactiveerd tijdens vakantiedagen 0 9 Tijdrooster Openingstijd Tijdrooster Sluitingstijd Tijdrooster Dagen (Omcirkel nummers van gewenste opties) Zondag Maandag Dinsdag Woensdag Donderdag Vrijdag Zaterdag Gedeactiveerd tijdens vakantiedagen 9 Tijdrooster Openingstijd Tijdrooster Sluitingstijd Tijdrooster Dagen (Omcirkel nummers van gewenste opties) Zondag Maandag Dinsdag Woensdag NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99 Donderdag Vrijdag Zaterdag Gedeactiveerd tijdens vakantiedagen

18 Uitbreidingsmodule NX-0/NX-0 NP Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of supply, 99 ADRES PAG OMSCHRIJVING STANDAARD DATA 9 Januari Vakantiedagen _ 9 Februari Vakantiedagen _ 9 Maart Vakantiedagen _ 9 9 April Vakantiedagen _ 0 9 Mei Vakantiedagen _ 9 Juni Vakantiedagen _ 9 Juli Vakantiedagen _ 9 Augustus Vakantiedagen _ 9 September Vakantiedagen _ 9 Oktober Vakantiedagen _ 9 November Vakantiedagen _ 9 December Vakantiedagen _ 0 CODES -0 SELECTIE UITGANGEN (Omcirkel te programmeren nummers) Gebruiker 9 0 Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # 9 0 CODES -0 SELECTIE UITGANGEN (Omcirkel te programmeren nummers) Gebruiker 9 0 Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # 0 0 CODES -0 SELECTIE UITGANGEN (Omcirkel te programmeren nummers) Gebruiker 9 0 Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # 0 CODES -0 SELECTIE UITGANGEN (Omcirkel te programmeren nummers) Gebruiker 9 0 Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang #

19 Uitbreidingsmodule NX-0/NX-0 NP Data and design are subject to change without notice / Supply subject to availability 9 Copyright - Details as per general conditions of supply, 99 0 CODES -0 SELECTIE UITGANGEN (Omcirkel te programmeren nummers) Gebruiker 9 0 Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # 0 CODES -0 SELECTIE UITGANGEN (Omcirkel te programmeren nummers) Gebruiker 9 0 Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # CODES -0 SELECTIE UITGANGEN (Omcirkel te programmeren nummers) Gebruiker 9 0 Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # CODES -0 SELECTIE UITGANGEN (Omcirkel te programmeren nummers) Gebruiker 9 0 Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # CODES -90 SELECTIE UITGANGEN (Omcirkel te programmeren nummers) Gebruiker 9 90 Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # CODES 9-99 SELECTIE UITGANGEN (Omcirkel te programmeren nummers) Gebruiker Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang # Uitgang #

20 Uitbreidingsmodule NX-0/NX-0. Technische specificaties Voedingsspanning (geleverd via NX- centrale of NX-0 voeding): nominaal: Vdc minimum/maximum: 9 Vdc - Vdc Vdc spanningsuitgang (Aux klem, stroom geleverd via NX- centrale of NX-0 voeding): max. stroomverbruik: 00 ma beperkt door NX-0 Stroomverbruik: minimaal: maximaal: 0 ma (geen uitgangen actief) ma (alle uitgangen actief) + stroomverbruik van elk apparaat dat aangesloten is op AUX uitgang van NX-0 Werkingstemperatuur: 0-0 C afmetingen: x mm gewicht: g. Software versies --00 : versie FB9 - Probleem opgelost voor paneel type herkenning NX- plus Aantal uitgangtypes werken nu nog tot zones : versie FB90 - Maximaal 99 codes kunnen gebruikt worden om een uitgang te sturen. - Gebeurtenissen toegevoegd: = Sturing uitgang via de NX. = Elke zoneverstoring, niet actief bij alarm. = Service status actief. 9 = In/aanwezig : versie B - Gebeurtenis 9 toegevoegd : In/aanwezig : versie 0AD - Functioneert met NX plus : versie B9 / versie 0C (v.0) - In logboek: uitgangsreset functie verplaatst naar adres en instelling klok naar adres 9. versie FFA - Probleem opgelost dat optrad als het logboek met meldingen vol was. versie CC - NX0 ondersteund logboek gebeurtenissen (alleen met tweetalig NX). versie 9 - Probleem dat veroorzaakt werd door automatisch uitschakelen van verschillende partities op verschillende tijden opgelost. - Probleem met printen als de e gebeurtenis was toegevoegd, opgelost. - Gebeurtenis : service led toegevoegd. versie A - Eerste versie. - Gebeurtenis : volg de zone bij niet in alarm en continu actief bij alarm. NP Data and design are subject to change without notice / Supply subject to availability 0 Copyright - Details as per general conditions of supply, 99

NetworX NX-508. Uitgangsmodule. Installatiehandleiding. Uitbreidingsmodule NX-508. Maart 1999

NetworX NX-508. Uitgangsmodule. Installatiehandleiding. Uitbreidingsmodule NX-508. Maart 1999 Uitbreidingsmodule NX-0 NX-0 Uitgangsmodule Installatiehandleiding Maart 999 NP009 9-0-999 Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per

Nadere informatie

NetworX NX-507/NX-508E

NetworX NX-507/NX-508E Uitbreidingsmodule NX-0/NX-0 NX-0/NX-0E Uitgangsmodule Installatiehandleiding November 00 NP009v november 00 Uitbreidingsmodule NX-0/NX-0 INHOUDSOPGAVE ALGEMENE BESCHRIJVING... INSTALLATIE VAN DE NX-0/NX-0....

Nadere informatie

NetworX NX-320. Handleiding NX-320. Intelligente voedingsmodule. Installatiehandleiding. April 1999

NetworX NX-320. Handleiding NX-320. Intelligente voedingsmodule. Installatiehandleiding. April 1999 NetworX NX-320 Intelligente voedingsmodule Installatiehandleiding April 1999 NP0094 27-07-2000 and design are subject to change without notice / Supply subject to availability 1 INHOUDSOPGAVE 1. ALGEMENE

Nadere informatie

Installatiehandleiding

Installatiehandleiding GE Security NetworX TM Series NX-216 Zone uitbreidingsmodule Installatiehandleiding g imagination at work NX-216 Installatiehandleiding Pag 2 17/06/05 INHOUDSOPGAVE INHOUDSOPGAVE... 3 ALGEMENE BESCHRIJVING...

Nadere informatie

Installatiehandleiding

Installatiehandleiding GE Security NetworX TM Series NX-320E Intelligente voeding Installatiehandleiding g imagination at work NX-320E Installatiehandleiding Pag 2 01/07/05 INHOUDSOPGAVE INHOUDSOPGAVE... 3 ALGEMENE BESCHRIJVING...

Nadere informatie

Handleiding NX-535. NetworX NX-535. Spraakmodule. Installatiehandleiding. oktober 2004

Handleiding NX-535. NetworX NX-535. Spraakmodule. Installatiehandleiding. oktober 2004 NetworX NX-535 Spraakmodule Installatiehandleiding oktober 2004 NP0190 Data and design are subject to change without notice / Supply subject to availability 1 INHOUDSOPGAVE 1 Algemene beschrijving...3

Nadere informatie

NetworX NX-1701E. Kaartlezer. Handleiding NX-1701E. Installatiehandleiding. september software 3.05 of hoger

NetworX NX-1701E. Kaartlezer. Handleiding NX-1701E. Installatiehandleiding. september software 3.05 of hoger NetworX NX-1701E Kaartlezer Installatiehandleiding september 2005 software 3.05 of hoger NP0103.2 Data and design are subject to change without notice / Supply subject to availability Copyright - Details

Nadere informatie

NetworX NX ProXPad. Handleiding NX Installatiehandleiding. oktober 2005

NetworX NX ProXPad. Handleiding NX Installatiehandleiding. oktober 2005 NetworX NX-1750 ProXPad Installatiehandleiding oktober 2005 NP0133 Data and design are subject to change without notice / Supply subject to availability Copyright - Details as per general conditions of

Nadere informatie

GEBRUIKERSHANDLEIDING. NetworX. Gebruikershandleiding

GEBRUIKERSHANDLEIDING. NetworX. Gebruikershandleiding Gebruikershandleiding - Betekenis van de LED s Aan LED Gereed LED Brand LED De AAN LED is aan wanneer het systeem ingeschakeld is. Als het systeem uitgeschakeld is dan staat de LED uit. Heeft er zich een

Nadere informatie

NX-1048-W. Installatiehandleiding (15/04/2009 V1.0)

NX-1048-W. Installatiehandleiding (15/04/2009 V1.0) NX-1048-W Installatiehandleiding (15/04/2009 V1.0) C-001-0417 IH_NX-1048-W_NL.doc Technische wijzigingen voorbehouden 1 1. Inhoudstabel. 1. Inhoudstabel... 2 2. Aansluitingen... 3 3. 1 e Opstart van het

Nadere informatie

GfS Day Alarm. Algemene omschrijving...p. 2. Montage handleiding en functies...p. 3. Instellingen van magneet contacten...p. 4

GfS Day Alarm. Algemene omschrijving...p. 2. Montage handleiding en functies...p. 3. Instellingen van magneet contacten...p. 4 Art.-Nr.: Art.-Nr.: Montage handleiding Inhoud Algemene omschrijving...p. Montage handleiding en functies...p. Instellingen van magneet contacten...p. Aansluiting met draadloos magneet contact...p. Aansluiting

Nadere informatie

Installateurshandleiding

Installateurshandleiding Installateurshandleiding EDS-18P Het EDS-18P codebediendeel is speciaal ontworpen voortoegangscontrole en het op afstand bedienen van een alarmmeldcentrale. 1. Kenmerken Microprocessor gestuurd. Alle gebruikerscodes

Nadere informatie

NetworX NX-408/416/448

NetworX NX-408/416/448 NX-408/46/448 Ontvangst module draadloos Installatiehandleiding november 999 NP0097. 5--999 Niets uit deze uitgave mag worden verveelvoudigd en/of openbaar gemaakt worden door middel van druk, fotokopie,

Nadere informatie

Handleiding NX-534E. NetworX NX-534E. Twee-weg audiomodule voor alarmverificatie. Installatiehandleiding. augustus 2005. NP0095.

Handleiding NX-534E. NetworX NX-534E. Twee-weg audiomodule voor alarmverificatie. Installatiehandleiding. augustus 2005. NP0095. NetworX NX-534E Twee-weg audiomodule voor alarmverificatie Installatiehandleiding augustus 2005 NP0095.2 augustus 2005 1 INHOUDSOPGAVE 1. ALGEMENE BESCHRIJVING...3 2. DEFINITIE VAN EIGENSCHAPPEN...3 3.

Nadere informatie

KNX INTEGRATIE MODULE int-knx-2_nl 03/15

KNX INTEGRATIE MODULE int-knx-2_nl 03/15 INT-KNX-2 KNX INTEGRATIE MODULE int-knx-2_nl 03/15 De INT-KNX-2 module integreert de INTEGRA / INTEGRA Plus alarmsystemen met het KNX systeem. Met gebruik van de module kan het alarmsysteem de actoren

Nadere informatie

NetworX NX-1048. Gebruikershandleiding voor NetworX beveiligingscentrales

NetworX NX-1048. Gebruikershandleiding voor NetworX beveiligingscentrales NetworX NX-1048 Gebruikershandleiding voor NetworX beveiligingscentrales Functies bediendeel Status LED (Aan, Uit, Gereed, Niet Gereed) LCD -display: Hier wordt informatie over de status van het systeem,

Nadere informatie

Gebruikershandleiding. voor NX-4 / NX-6 / NX-8 / NX-8PLUS

Gebruikershandleiding. voor NX-4 / NX-6 / NX-8 / NX-8PLUS Centrale met geïntegreerde multi-formaat communicator geschikt voor up- en downloading Gebruikershandleiding voor NX-4 / NX-6 / NX-8 / NX-8PLUS Versie Maart 2003 BVVO keuring : BIS/REC/696 BZ-MI keuring

Nadere informatie

K-Steel deuropenermodule 1156/10 met numeriek toetsenbord

K-Steel deuropenermodule 1156/10 met numeriek toetsenbord K-Steel deuropenermodule 1156/10 met numeriek toetsenbord Versie 2.0 - februari 2007 Aan deze uitgave kunnen geen rechten worden ontleend. Wijzigingen voorbehouden. Mogelijkheden De deuropenermodule kan

Nadere informatie

GEBRUIKERSHANDLEIDING. NetworX. Gebruikershandleiding

GEBRUIKERSHANDLEIDING. NetworX. Gebruikershandleiding Gebruikershandleiding NP0122 01-8-2002 NP0122 1-8-2002 2 NP0122 1-8-2002 3 INHOUDSOPGAVE ALGEMEEN...5 LIJST MET COMMANDO S...7 INSCHAKELEN...8 Systeem niet gereed in te schakelen...8 UITSCHAKELEN...8 Herstellen

Nadere informatie

SIM plaatsen rode en groene LED

SIM plaatsen rode en groene LED MODELLEN GSM07 BESCHRIJVING De GSM07 is een compacte QuadBand GSM module. De unit is ontworpen om via de mobiele telefoon toegang te verkrijgen tot woningen, parkeergarages of andere gebouwen of toepassingen.

Nadere informatie

CODEKLAVIER PROGRAMMATIE HANDLEIDING

CODEKLAVIER PROGRAMMATIE HANDLEIDING 4-019 99104 CODEKLAVIER PROGRAMMATIE HANDLEIDING Index 1. Eigenschappen 3. Specificaties 3 3. Installatie - aansluiting 3 4. Bedradingen 4 5. Aansluitschema 4 6. Reset 5 7. Geluid en licht indicatie 5

Nadere informatie

EV455AM / EV456AM TECHNISCHE GEGEVENS V DC 2 V tt bij 12 V DC 6 ma in rust (EV456AM - 6 ma) 18 ma tijdens alarm (EV456AM - 18 ma) Auto Focus

EV455AM / EV456AM TECHNISCHE GEGEVENS V DC 2 V tt bij 12 V DC 6 ma in rust (EV456AM - 6 ma) 18 ma tijdens alarm (EV456AM - 18 ma) Auto Focus EV455AM / EV456AM Passief infrarood detector met precisie spiegeloptiek en autofocus. Biedt anti-mask detectie. Bezit 1 gordijnveld van 25 m. Instelbaar detectiebereik en een intelligente "4D" signaalverwerking.

Nadere informatie

Verkorte Gebruiker Handleiding

Verkorte Gebruiker Handleiding Verkorte Gebruiker Handleiding Inhoud Algemeen... 3 Het keypad... 3 Functietoetsen... 4 Cijfertoetsen... 4 Navigatietoetsen... 4 LCD scherm... 4 Signalisatie LED s... 6 Noodtoetsen... 6 De verschillende

Nadere informatie

GEBRUIKERSHANDLEIDING. NetworX. Gebruikershandleiding

GEBRUIKERSHANDLEIDING. NetworX. Gebruikershandleiding Gebruikershandleiding NP0098.1 14-4-2000 Niets uit deze uitgave mag worden verveelvoudigd en/of openbaar gemaakt worden door middel van druk, fotokopie, microfilm, geluidsband, elektronisch of op welke

Nadere informatie

ADRESSEERBARE ZONE UITBREIDING int-adr_nl 05/14

ADRESSEERBARE ZONE UITBREIDING int-adr_nl 05/14 INT-ADR ADRESSEERBARE ZONE UITBREIDING int-adr_nl 05/14 De INT-ADR uitbreiding is voor uitbreiding van het alarmsysteem met tot 48 adresseerbare zones en ondersteund de CA-64 ADR-MOD adresseerbare detector

Nadere informatie

NetworX NX-4SE NX-6SE NX-8SE

NetworX NX-4SE NX-6SE NX-8SE NetworX NX-4SE NX-6SE NX-8SE Centrale met geïntegreerde multi-formaat communicator geschikt voor up- en downloading Installatie- en programmeer handleiding april 2007 NP0132 versie 1.2 1 INHOUDSOPGAVE

Nadere informatie

De verklaring van overeenstemming kan worden geraadpleegd op

De verklaring van overeenstemming kan worden geraadpleegd op SPRAAKBERICHTEN GENERATOR INT-VMG int-vmg_nl 03/12 De INT-VMG module is voor het luid afspelen van voor opgenomen berichten indien een bepaalde gebeurtenis optreed. De module kan gebruikt worden in samenwerking

Nadere informatie

InteGra Gebruikershandleiding 1

InteGra Gebruikershandleiding 1 InteGra Gebruikershandleiding 1 Algemeen Met dank voor de keuze van dit product aangeboden door SATEL. Hoge kwaliteit en vele functies met een simpele bediening zijn de voordelen van deze inbraak alarmcentrale.

Nadere informatie

GEBRUIKERSHANDLEIDING

GEBRUIKERSHANDLEIDING NP0060.1 juli 1996 INLEIDING De is een inbraakalarmcentrale met maximaal 6 detectiepunten die bediend kan worden m.b.v. het LED of LCD bediendeel. De commando s die vanuit het bediendeel worden ingegeven

Nadere informatie

GT-912/GT-913/GT-914 Gebruikers handleiding

GT-912/GT-913/GT-914 Gebruikers handleiding GT-912/GT-913/GT-914 Gebruikers handleiding Rho-Delta b.v. Escudostraat 2 2991 XV Barendrecht Tel. +03110-4795755 Fax. +03110-2927461 www.rhodelta.nl info@rhodelta.nl - OMSCHRIJVING De GT-912 /GT-913/GT-914

Nadere informatie

Gebruikershandleiding. Brandmeldcentrale JUNO-NET EN54

Gebruikershandleiding. Brandmeldcentrale JUNO-NET EN54 Gebruikershandleiding Brandmeldcentrale JUNO-NET EN54 Copyright TEF Nederland erland B.V. Inhoud: 1.1. Omschrijving Bediening Brandmeldcentrale 1.2. Alarmsituatie 1.3. Reset de brandmeldcentrale 1.4. Starten

Nadere informatie

Met het MKP-300 bediendeel kunt u het MICRA Alarmsysteem bedienen. Deze werkt alleen als de MICRA module in de alarm module mode is ingesteld.

Met het MKP-300 bediendeel kunt u het MICRA Alarmsysteem bedienen. Deze werkt alleen als de MICRA module in de alarm module mode is ingesteld. MKP-300 DRAADLOOS BEDIENDEEL MKP300_NL 03/12 Met het MKP-300 bediendeel kunt u het MICRA Alarmsysteem bedienen. Deze werkt alleen als de MICRA module in de alarm module mode is ingesteld. 1. Eigenschappen

Nadere informatie

LCD-gebruikersgids - standaard. Systeem gereed Aan:geef code. Systeem niet gereed Info:tikv - S. Systeem gereed Aan:geef code

LCD-gebruikersgids - standaard. Systeem gereed Aan:geef code. Systeem niet gereed Info:tikv - S. Systeem gereed Aan:geef code LCD-gebruikersgids - standaard Alle zones in rust ysteem gereed Zone(s) open ysteem niet gereed Info:tikv j k 2 Fout of 2 Ok Zone 2 Zone 2 ysteem inschakelen - ysteem gereed of h ysteem aan Alle zones

Nadere informatie

Installatiehandleiding

Installatiehandleiding GE Security NetworX TM Series NX-534E 2-weg audiomodule Installatiehandleiding g imagination at work NX-534E Installatiehandleding Pag 2 01/07/05 INHOUDSOPGAVE INHOUDSOPGAVE... 3 ALGEMENE BESCHRIJVING...

Nadere informatie

KNX INTEGRATIE MODULE INT-KNX

KNX INTEGRATIE MODULE INT-KNX KNX INTEGRATIE MODULE INT-KNX int-knx_nl 09/11 De INT-KNX module integreert het INTEGRA alarmsysteem met het KNX systeem, waardoor de centrale de aangesloten actoren op de KNX bus kan bedienen, en de bus

Nadere informatie

COPYRIGHT GARANTIEBEPERKINGEN

COPYRIGHT GARANTIEBEPERKINGEN COPYRIGHT SLC BV 1996. All rechten voorbehouden. Niets uit deze uitgave mag worden verveelvoudigd, overgebracht, opgeslagen in een opslagsysteem of doorgegeven in welke vorm of op welke manier ook - elektronisch,

Nadere informatie

EV435AM / EV436AM TECHNISCHE GEGEVENS V DC 2 V tt bij 12 V DC 5 ma in rust (EV436AM - 5 ma) 18 ma tijdens alarm (EV436AM - 18 ma) Auto Focus

EV435AM / EV436AM TECHNISCHE GEGEVENS V DC 2 V tt bij 12 V DC 5 ma in rust (EV436AM - 5 ma) 18 ma tijdens alarm (EV436AM - 18 ma) Auto Focus EV435AM / EV436AM Passief infrarood detector met precisie spiegeloptiek en autofocus. Biedt anti-mask detectie. Bezit 9 gordijnvelden van 15 m. Instelbaar detectiebereik en een intelligente "4D" signaalverwerking.

Nadere informatie

CS series LED-gebruikersgids

CS series LED-gebruikersgids CS-175-275-575 series LED-gebruikersgids 98/482/EC-kennisgeving (Voor producten met CE-certificering) Deze apparatuur voldoet aan beschikking 98/482/EC van de Europese Raad inzake Pan-Europese voorschriften

Nadere informatie

Series. NX-4-EUR Inbraakcentrale. Installatiehandleiding

Series. NX-4-EUR Inbraakcentrale. Installatiehandleiding GE Security NetworX TM Series NX-4-EUR Inbraakcentrale Installatiehandleiding g imagination at work NX-4-EUR Installatiehandleiding Pag 2 02/07/06 INHOUDSOPGAVE INHOUDSOPGAVE... 3 ALGEMENE BESCHRIJVING...

Nadere informatie

HANDLEIDING WINDMETER IED SAG-105WR (10/2009)

HANDLEIDING WINDMETER IED SAG-105WR (10/2009) HANDLEIDING WINDMETER IED SAG-105WR (10/2009) indic bvba, Molenberglei 21, B-2627 Schelle, tel +32(0)3 451 93 93 - fax +32(0)3 887 30 61 www.indiconline.com 1 Inhoud 1 Inhoud... 2 2 CE certificaat... 3

Nadere informatie

NetworX NX-6 NX-8 NX-8plus

NetworX NX-6 NX-8 NX-8plus NetworX NX-6 NX-8 NX-8plus Centrale met geïntegreerde multi-formaat communicator geschikt voor up- en downloading Installatie- en programmeer handleiding juni 2001 NP0096.1 1-6-2001 1 INHOUDSOPGAVE 1.

Nadere informatie

EV475AM / EV476AM TECHNISCHE GEGEVENS V DC 2 V tt bij 12 V DC 5 ma in rust (EV476AM - 5 ma) 18 ma tijdens alarm (EV476AM - 18 ma) Auto Focus

EV475AM / EV476AM TECHNISCHE GEGEVENS V DC 2 V tt bij 12 V DC 5 ma in rust (EV476AM - 5 ma) 18 ma tijdens alarm (EV476AM - 18 ma) Auto Focus EV475AM / EV476AM Passief infrarood detector met precisie spiegeloptiek en autofocus. Biedt anti-mask detectie. Bezit 9 gordijnvelden van 15 m. Instelbaar detectiebereik en een intelligente "4D" signaalverwerking.

Nadere informatie

SPRAAK MODULE INT-VG. 1. Eigenschappen. 2. Specificaties

SPRAAK MODULE INT-VG. 1. Eigenschappen. 2. Specificaties SPRAAK MODULE INT-VG int-vg_nl 12/11 De INT-VG module werkt samen met de INTEGRA en VERSA alarmsystemen en maakt implementatie van spraakberichten mogelijk (deze module vervangt de CA-64 SM spraak synthesizer

Nadere informatie

COPYRIGHT GARANTIEBEPERKINGEN

COPYRIGHT GARANTIEBEPERKINGEN COPYRIGHT SLC BV 1996. All rechten voorbehouden. Niets uit deze uitgave mag worden verveelvoudigd, overgebracht, opgeslagen in een opslagsysteem of doorgegeven in welke vorm of op welke manier ook - elektronisch,

Nadere informatie

GT909NL. Gebruikershandleiding

GT909NL. Gebruikershandleiding GT909NL Gebruikershandleiding Rhodelta b.v. Escudostraat 2 2991 XV Barendrecht Tel. +31 102927461 Fax + 31 104795755 www.rhodelta.nl info@rhodelta.nl 1.0 HANDZENDER OMSCHRIJVING GT889 GT969CH GT889: handzender

Nadere informatie

DIN-RAIL UITBREIDING int-iors_nl 10/14

DIN-RAIL UITBREIDING int-iors_nl 10/14 INT-IORS INT-ORS DIN-RAIL UITBREIDING int-iors_nl 10/14 De INT-IORS uitbreiding is voor uitbreiding van het alarmsysteem met 8 programmeerbare bedrade zones en 8 programmeerbare bedrade uitgangen. De modules

Nadere informatie

Gebruikershandleiding CS-175 CS-275 CS-575 LCD Codeklavier

Gebruikershandleiding CS-175 CS-275 CS-575 LCD Codeklavier Gebruikershandleiding CS-175 CS-275 CS-575 LCD Codeklavier Puurs EL 03 V w 8 A w 8 S w 6 ec.e 6 u lv 6 rit a. 56 y be CS-175-275-575 series LCD-gebruikersgids 98/482/EC-kennisgeving (Voor producten met

Nadere informatie

Jacobs Beveiliging bvba Pagina 1

Jacobs Beveiliging bvba Pagina 1 GEBRUIKERS HANDLEIDING TEXECOM PREMIER 412/816/832 De toetsposities zijn op de klavieren steeds identiek, sommige benamingen/ kunnen verschillen. Elk systeem is ingesteld volgens uw persoonlijke behoeften!

Nadere informatie

HANDLEIDING CIFERO XT CODEKLAVIER

HANDLEIDING CIFERO XT CODEKLAVIER HANDLEIDING CIFERO XT CODEKLAVIER April 2014 TECHNISCHE GEGEVENS Aansluitspanning 12 tot 24V AC/DC ±20% Stroomverbruik in rust o bij gelijkspanning 20mA DC o bij wisselspanning 80mA AC Maximaal stroomverbruik

Nadere informatie

InteGra Gebruikershandleiding 1 INHOUD 1. ALGEMEEN... 2 2. DE INTEGRA INBRAAKCENTRALE... 2 2.1 LCD BEDIENDEEL...3 2.1.1 Display... 3 2.1.2 Toetsen...

InteGra Gebruikershandleiding 1 INHOUD 1. ALGEMEEN... 2 2. DE INTEGRA INBRAAKCENTRALE... 2 2.1 LCD BEDIENDEEL...3 2.1.1 Display... 3 2.1.2 Toetsen... InteGra Gebruikershandleiding 1 INHOUD 1. ALGEMEEN... 2 2. DE INTEGRA INBRAAKCENTRALE... 2 2.1 LCD BEDIENDEEL...3 2.1.1 Display... 3 2.1.2 Toetsen... 3 2.1.3 LED indicatoren op het LCD bediendeel... 4

Nadere informatie

AC-239-2 ZONE ALARMCONTROLLER MET DEURBEL HANDLEIDING

AC-239-2 ZONE ALARMCONTROLLER MET DEURBEL HANDLEIDING AC-239-2 ZONE ALARMCONTROLLER MET DEURBEL HANDLEIDING Handleiding AC-239 1. Beschrijving Uw AC-239 is een economische en veelzijdige alarmcontroller uitgerust met twee beveiligingszones en ingebouwde deurbel.

Nadere informatie

Series. NX-8-EUR Inbraakcentrale. Installatiehandleiding

Series. NX-8-EUR Inbraakcentrale. Installatiehandleiding GE Security NetworX TM Series NX-8-EUR Inbraakcentrale Installatiehandleiding g imagination at work NX-8-EUR Installatiehandleiding Pag 2 02/07/06 INHOUDSOPGAVE INHOUDSOPGAVE... 3 ALGEMENE BESCHRIJVING...

Nadere informatie

Gebruikershandleiding. Bedienpaneel MINI-REP

Gebruikershandleiding. Bedienpaneel MINI-REP Gebruikershandleiding Bedienpaneel MINI-REP Inhoud: 1.1. Omschrijving Bediening Brandmeldcentrale 1.2. Alarmsituatie 1.3. Reset de brandmeldcentrale 1.4. Starten en stoppen van de Ontruiming 1.5. Uitlezen

Nadere informatie

Elektronische sluitertijd 1/50 tot 1/100000 auto dubbel pyroelektrisch element

Elektronische sluitertijd 1/50 tot 1/100000 auto dubbel pyroelektrisch element Z/W CCD PIR CAMERA SPECIFICATIES Opneem element 1/3" SONY CCD beeldsensor Aantal pixels 500(H) x 582(V) Resolutie 400 TV lijnen Min. illuminantie 0.1 Lux / F2.0 S/R-verhouding meer dan 48dB Elektronische

Nadere informatie

installatiehandleiding Alarmlicht met sirene

installatiehandleiding Alarmlicht met sirene installatiehandleiding Alarmlicht met sirene INSTALLATIEHANDLEIDING ALARMLICHT MET SIRENE Gefeliciteerd met de aankoop van het WoonVeilig alarmlicht met sirene. Telefoonnummer WoonVeilig 0900-388 88 88

Nadere informatie

GE Interlogix CS5500 LCD bediendeel Gebruikershandleiding

GE Interlogix CS5500 LCD bediendeel Gebruikershandleiding g GE Interlogix CS5500 LCD bediendeel Gebruikershandleiding September 2003 98/482/EC-kennisgeving (voor producten met CE-certificering) Deze apparatuur voldoet aan beschikking 98/482/EC van de Europese

Nadere informatie

NX-848E Gen2. Installatiehandleiding (19/10/2012 V1.0) IH_NX-848E_NL.doc Technische wijzigingen voorbehouden 1

NX-848E Gen2. Installatiehandleiding (19/10/2012 V1.0) IH_NX-848E_NL.doc Technische wijzigingen voorbehouden 1 NX-848E Gen2 Installatiehandleiding (19/10/2012 V1.0) IH_NX-848E_NL.doc Technische wijzigingen voorbehouden 1 1. Inhoudstabel. 1. Inhoudstabel... 2 2. Draadloze ontvanger NX-848E.... 3 2.1. Hardware....

Nadere informatie

HANDLEIDING MEMOKEY 100C

HANDLEIDING MEMOKEY 100C 1 HANDLEIDING MEMOKEY 100C 1 lksdj WOORD VOORAF BIJ PROGRAMMATIE! Het aangeraden, eens het systeem is geïnstalleerd, de code lengte te bepalen en de MASTER en TRADE code te wijzigen. Nadien kunnen andere

Nadere informatie

PUNT MET-LOK Installatie & Programmering

PUNT MET-LOK Installatie & Programmering PUNT MET-LOK Installatie & Programmering INHOUD Hoofdstuk Omschrijving Pagina 1 ALGEMENE INFORMATIE ---------------------------------------------------- 2 1.1 Toepassing-------------------------------------------------------------------------

Nadere informatie

GfS Day Alarm. Montage handleiding. Art.-Nr.: / Art.-Nr.: Art.-Nr.: Art.-Nr.: Art.-Nr.: Art.-Nr.:

GfS Day Alarm. Montage handleiding. Art.-Nr.: / Art.-Nr.: Art.-Nr.: Art.-Nr.: Art.-Nr.: Art.-Nr.: Art.-Nr.: Art.-Nr.: Art.-Nr.: GfS Day Alarm Montage handleiding Art.-Nr.: 00000/0000 Art.-Nr.: 0000 Art.-Nr.: 0000 Jons Joosten Doezastraat HA Leiden Telefoon + (0) Fax + (0) www.nooduitgang.nl Art.-Nr.:

Nadere informatie

installatiehandleiding Alarmlicht

installatiehandleiding Alarmlicht installatiehandleiding Alarmlicht INSTALLATIEHANDLEIDING ALARMLICHT Gefeliciteerd met de aankoop van het WoonVeilig alarmlicht. Telefoonnummer WoonVeilig 0900-388 88 88 E-mail WoonVeilig klantenservice@woonveilig.nl

Nadere informatie

Gebruikershandleiding. Brandmeldcentrale JUNO-NET EN54

Gebruikershandleiding. Brandmeldcentrale JUNO-NET EN54 Gebruikershandleiding Brandmeldcentrale JUNO-NET EN54 Inhoud: 1.1. Omschrijving Bediening Brandmeldcentrale 1.2. Alarmsituatie 1.3. Reset de brandmeldcentrale 1.4. Starten en stoppen van de Ontruiming

Nadere informatie

Syncro AS. Analoge Brandmeldcentrale. Gebruikershandleiding. Man V1.0NL

Syncro AS. Analoge Brandmeldcentrale. Gebruikershandleiding. Man V1.0NL Syncro AS Analoge Brandmeldcentrale Gebruikershandleiding Man-1100 030209V1.0NL Index Section Page 1. Inleiding...2 2. Bediening...2 3.1 Bedieningsniveau 1...2 3.2 Bedieningsniveau 2...2 3. Alarmen...2

Nadere informatie

Gebruikershandleiding CS-175 CS-275 CS-575 LED Codeklavier

Gebruikershandleiding CS-175 CS-275 CS-575 LED Codeklavier Gebruikershandleiding CS-175 CS-275 CS-575 LED Codeklavier Puurs EL 03 V w 8 A w 8 S w 6 ec.e 6 u lv 6 rit a. 56 y be CS-175-275-575 series LED-gebruikersgids 98/482/EC-kennisgeving (Voor producten met

Nadere informatie

PROGRAMMEERBARE TEMPERATUUR DETECTOR TD-1_NL 07/11

PROGRAMMEERBARE TEMPERATUUR DETECTOR TD-1_NL 07/11 TD-1 PROGRAMMEERBARE TEMPERATUUR DETECTOR TD-1_NL 07/11 1. Toepassingen De detector kan temperatuur meten en worden gebruikt om informatie te tonen over: Te lage temperatuur, bijv. in kassen, bloemenwinkels,

Nadere informatie

Installatie instructies

Installatie instructies 1 Installatie instructies 04-2016 VEILIGHEID EN CORRECT GEBRUIK Om veiligheid en een lange levensduur van dit product te garanderen, zal u de bijgesloten instructies strikt in acht moeten nemen. Uw garantie

Nadere informatie

CODEKLAVIER PROGRAMMATIE HANDLEIDING

CODEKLAVIER PROGRAMMATIE HANDLEIDING 04.05 99005 CODEKLAVIER PROGRAMMATIE HANDLEIDING . Eigenschappen Waterdichtheid IP5 Anti-vandaal behuizing Volledige programmering via het codeklavier 000 gebruikers, magneetsleutel, openingscode 4 tot

Nadere informatie

TS680. Alarmcentrale. Gebruikershandleiding

TS680. Alarmcentrale. Gebruikershandleiding TS680 Alarmcentrale Gebruikershandleiding Inhoud Hoofdstuk/menu Omschrijving Pagina 0.1 Inschakelen alarmsysteem 2 0.2 Uitschakelen alarmsysteem 2 1.1 Sirene/flitser test 3 1.2 Looptest 3 1.4 Wijzigen

Nadere informatie

FAQ en HANDLEIDINGEN. MEER HANDLEIDINGEN: kijk op faq.koba-groep.com

FAQ en HANDLEIDINGEN. MEER HANDLEIDINGEN: kijk op faq.koba-groep.com FAQ en HANDLEIDINGEN MEER HANDLEIDINGEN: kijk op faq.koba-groep.com Gebruikershandleiding Brandmeldcentrale Junior V4 Inhoud: 1.1. Omschrijving Bediening Brandmeldcentrale 1.2. Alarmsituatie 1.3. Reset

Nadere informatie

FAQ en HANDLEIDINGEN. MEER HANDLEIDINGEN: kijk op faq.koba-groep.com

FAQ en HANDLEIDINGEN. MEER HANDLEIDINGEN: kijk op faq.koba-groep.com FAQ en HANDLEIDINGEN MEER HANDLEIDINGEN: kijk op faq.koba-groep.com Gebruikershandleiding Brandmeldcentrale JUNO-NET EN54 Inhoud: 1.1. Omschrijving Bediening Brandmeldcentrale 1.2. Alarmsituatie 1.3. Reset

Nadere informatie

04/2015 Vanaf serienummer : CODEKLAVIER PROGRAMMATIE HANDLEIDING

04/2015 Vanaf serienummer : CODEKLAVIER PROGRAMMATIE HANDLEIDING 04/05 Vanaf serienummer : 0500090 99004 CODEKLAVIER PROGRAMMATIE HANDLEIDING . Eigenschappen Waterdichtheid IP68 Antivandaal behuizing relais Beide relais kunnen met openingscode, magneetsleutel of magneetsleutel

Nadere informatie

Integratie van Net2 met een inbraakalarmsysteem

Integratie van Net2 met een inbraakalarmsysteem Integratie van met een inbraakalarm Overzicht kan controleren of het inbraakalarm in of uit geschakeld is. Als het alarm aan staat zal alleen toegang verlenen aan gebruikers die gemachtigd zijn om het

Nadere informatie

NP0052.04. Gebruikershandleiding CMK470S

NP0052.04. Gebruikershandleiding CMK470S NP0052.04 Gebruikershandleiding januari 1998 Niets uit deze uitgave mag worden verveelvoudigd en/of openbaar gemaakt worden door middel van druk, fotokopie, microfilm, geluidsband, elektronisch of op welke

Nadere informatie

ProSYS Plus Verkorte gebruikershandleiding

ProSYS Plus Verkorte gebruikershandleiding ProSYS Plus Verkorte gebruikershandleiding Volledig inschakelen (voor afwezigheid) Code Volledig inschakelen: Beveiliging. proximity tag code of met om alle partities in te schakelen of om een specifieke

Nadere informatie

2014-03-21 GSM500 PROGRAMMATIE HANDLEIDING

2014-03-21 GSM500 PROGRAMMATIE HANDLEIDING 2014-03-21 GSM500 PROGRAMMATIE HANDLEIDING 1. Aansluitschema 2. Specificaties Voedingsspanning 7-32 Vdc GSM frequentie GSM 850/900/1800/1900 MHz Werkingstemperatuur -20 C tot + 55 C Gewicht 220 gr Afmetingen

Nadere informatie

Handleiding BUS-2 Relais (3247)

Handleiding BUS-2 Relais (3247) Mogelijkheden Het BUS-2 relais heeft een potentiaal vrij wisselcontact (max. 5 A), dit contact kan op meerdere manieren aangestuurd worden. - Via 1 of meerdere of alle beldrukkers van het deurstation.

Nadere informatie

NX-595 App instelling instructie UltraConnect maart 2016

NX-595 App instelling instructie UltraConnect maart 2016 NX-595 Programmering Met de NX-595E is het mogelijk om via de UltraConnect App (en webbrowser) verbinding te maken met het NX-systeem. Om bijvoorbeeld in/uit te schakelen, logboek te lezen, relais te activeren

Nadere informatie

HANDLEIDING VASCO TIMER MODULE TIMER MODULE

HANDLEIDING VASCO TIMER MODULE TIMER MODULE HANDLEIDING VASCO TIMER MODULE TIMER MODULE INHOUDSTABEL 1. INLEIDING 01 2. VEILIGHEID 01 3. WERKING 01 4. OBOUW 02 ALGEMEEN 02 MAATTEKENING 02 MONTAGE 02 ELEKTRISCH SCHEMA 04 4.1 AANSLUITING D300E II

Nadere informatie

NL PROGRAMMERINGS HANDLEIDING. Digitale elektronische sleutelmodule art. 3348B / 3348BM. Passion.Technology.Design.

NL PROGRAMMERINGS HANDLEIDING. Digitale elektronische sleutelmodule art. 3348B / 3348BM. Passion.Technology.Design. NL PROGRAMMERINGS HANDLEIDING Digitale elektronische sleutelmodule art. 3348B / 3348BM Passion.Technology.Design. Inhoud Waarschuwingen Beschrijving... 3 Programmering en werking... 3 Invoeren van de supercode...3

Nadere informatie

Tyro Pyxis/Auriga 2, 4, 6 of 8 voudige afstandsbediening Handleiding 868 MHz

Tyro Pyxis/Auriga 2, 4, 6 of 8 voudige afstandsbediening Handleiding 868 MHz Handleiding 868 MHz Pyxis zender en Auriga ontvanger Aantal functies: 2, 4, 6 of 8, ON/OFF Toetsfuncties Pyxis zender activeren: houdt de I knop 2 seconden ingedrukt. Pyxis zender deactiveren: houdt de

Nadere informatie

Technische handleiding

Technische handleiding Technische handleiding CodeAccess 11 Code bediendeel met losse centrale Aanvullende informatie Artikelnummer : CA11 Versie : 2.2, September 2013 Postbus 218 5150 AE Drunen Thomas Edisonweg 5 5151 DH Drunen

Nadere informatie

NX-148. Gebruikershandleiding. Intelligent Security bvba - Stationstraat 12-8710 Wielsbeke www.intelligentsecurity.be - 050/333.666-056/666.

NX-148. Gebruikershandleiding. Intelligent Security bvba - Stationstraat 12-8710 Wielsbeke www.intelligentsecurity.be - 050/333.666-056/666. NX-148 Gebruikershandleiding Intelligent Security bvba - Stationstraat 12-8710 Wielsbeke www.intelligentsecurity.be - 050/333.666-056/666.933 GEBRUIK VAN HET SYSTEEM VIA LCD CODEKLAVIER Betekenis van de

Nadere informatie

ATS2000 Controle Paneel Quick Reference Guide

ATS2000 Controle Paneel Quick Reference Guide ATS2000 Controle Paneel Quick Reference Guide Wat zijn de aansluitingen van de ATS2000? 2 Hoe sluit ik een ATS 1202 aan? 3 Hoe sluit ik een ATS1100 (GI)aan? 4 Hoe sluit ik de ATS7200 (voice module) aan?

Nadere informatie

Technische handleiding

Technische handleiding Technische handleiding CA626S-200 Stand-Alone code bediendeel met geïntegreerd relais Aanvullende informatie Artikelnummer : CA626S-200 Versie : 1.5 Uitgave: Juni 2015 Postbus 218 5150 AE Drunen Thomas

Nadere informatie

Vanaf SN : CODEKLAVIER PROGRAMMATIE HANDLEIDING

Vanaf SN : CODEKLAVIER PROGRAMMATIE HANDLEIDING Vanaf SN : 000.0 9900 CODEKLAVIER PROGRAMMATIE HANDLEIDING . Eigenschappen Waterdichtheid IP68 Anti-vandaal behuizing Volledige programmering via het codeklavier 000 gebruikers, magneetsleutel, openingscode,

Nadere informatie

TS790/TS & groepen Alarmcentrale. Beheerdershandleiding

TS790/TS & groepen Alarmcentrale. Beheerdershandleiding TS790/TS890 10-16 & 10-56 groepen Alarmcentrale Beheerdershandleiding Inhoud Hoofdstuk Omschrijving Pagina 0.1 Inschakelen alarmsysteem 2 0.2 Uitschakelen alarmsysteem 2 1.1 Sirene/flitser test 3 1.2 Looptest

Nadere informatie

EV645 / EV646 TECHNISCHE GEGEVENS V DC 2 V tt 15 ma in rust (EV ma) 26 ma tijdens alarm (EV ma) 4D-signaalverwerking

EV645 / EV646 TECHNISCHE GEGEVENS V DC 2 V tt 15 ma in rust (EV ma) 26 ma tijdens alarm (EV ma) 4D-signaalverwerking EV645 / EV646 High security passief infrarood detector met precisie spiegeloptiek. Gordijn van 12 m, groothoek tot 24 m en long beam tot 60 m. Intelligente 4D signaalverwerking om ongewenste alarmen te

Nadere informatie

Gebruikershandleiding

Gebruikershandleiding GE Security NetworX TM Series NX-4-EUR/NX-6-EUR/NX-8-EUR/N8E NX-8E/NX-8-EUR/NX-6-EUR/NX-4-EUR Gebruikershandleiding g imagination at work NX-8E/NX-8-EUR/ NX-6-EUR/NX-4-EUR Gebruikershandleiding Page 2

Nadere informatie

Na enige tijd ziet u het volgende scherm. De gegevens zijn uit de GSM kiezer gehaald.

Na enige tijd ziet u het volgende scherm. De gegevens zijn uit de GSM kiezer gehaald. Handleiding GSM Kiezer PL SW versie 8.8.1 Start het programma GSM-SW op. Nu verschijnt het hoofdmenu. Sluit de usb kabel aan van de GSM kiezer. De driver wordt geinstalleerd. Het volgende scherm wordt

Nadere informatie

NetworX NX-8plus - gebruiksvriendelijk en klaar voor de toekomst

NetworX NX-8plus - gebruiksvriendelijk en klaar voor de toekomst NetworX NX-8plus - gebruiksvriendelijk en klaar voor de toekomst Door zijn modulair concept opent de NetworX NX-8plus centrale nieuwe horizonten. De basisconfiguratie van het NetworX systeem bestaat uit

Nadere informatie

2-KANAALS RF AFSTANDSBEDIENINGSSET

2-KANAALS RF AFSTANDSBEDIENINGSSET MODULES VM130 HANDLEIDING 2-KANAALS RF AFSTANDSBEDIENINGSSET WWW.VELLEMANPROJECTS.EU Inhoudstafel Beschrijving 3 Eigenschappen en technische gegevens 4 Instructies voor de zender 4 Instructies voor de

Nadere informatie

Marmitek MicroModule AWM 2

Marmitek MicroModule AWM 2 Marmitek MicroModule AWM 2 Marmitek X10 zender voor twee adressen met ingebouwde apparaatmodule Toepassingen Door de extreem kleine afmetingen kan de module ingebouwd worden achter inbouwschakelaars en

Nadere informatie

VERSA / VERSA Plus Verkorte gebruikershandleiding

VERSA / VERSA Plus Verkorte gebruikershandleiding int-tsg_gv_nl 05/15 Bediendeel INT-TSG Firmware versie 1.03 VERSA / VERSA Plus Verkorte gebruikershandleiding SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. 58 320 94 00 www.satel.eu WAARSCHUWINGEN

Nadere informatie

ProSYS Plus. Verkorte Gebruikershandleiding. Pagina 1

ProSYS Plus. Verkorte Gebruikershandleiding. Pagina 1 ProSYS Plus Verkorte Gebruikershandleiding Pagina 1 Gebruikershandleiding ProSYS Plus Bij RISCO Cloud aanmelden (indien ingeschakeld) Als u zich aanmeldt bij RISCO Cloud kunt u toezicht houden op uw ProSYS

Nadere informatie

Geeft een storingstoestand aan Het systeem of partitie is uitgeschakeld. Opmerking:

Geeft een storingstoestand aan Het systeem of partitie is uitgeschakeld. Opmerking: Het RISCO Group's Touchscreen Keypad is een dun en modern design keypad van 7" (17,8cm) voor het ProSYS beveiliging systeem. Het is compatible met alle ProSYS versie en beschikbaar met en zonder proximitylezer.

Nadere informatie

Gebruiker Handleiding Premier 412/816/832 INS477

Gebruiker Handleiding Premier 412/816/832 INS477 Gebruiker Handleiding Premier 412/816/832 INS477 Premier 412/816/832 Gebruiker Handleiding Bediening van het systeem Dit document behandelt de alledaagse bediening van uw alarm systeem, voor meer uitgebreide

Nadere informatie

MiniAir BEKNOPTE HANDLEIDING EN INSTRUCTIEHANDLEIDING

MiniAir BEKNOPTE HANDLEIDING EN INSTRUCTIEHANDLEIDING MiniAir BEKNOPTE HANDLEIDING EN INSTRUCTIEHANDLEIDING Volledige Complete connectiviteitsoplossingen Connectivity Solutions CSL - de the vertrouwde trusted choice keus www.csldual.com @CSLDualCom CSL DualCom

Nadere informatie

Installatiehandleiding CL-163

Installatiehandleiding CL-163 Installatiehandleiding CL-163 CODESLOT JADE Electronics Putterplein 1 4281 PP ANDEL Postbus 40 4254 ZG SLEEUWIJK Tel : 0183-303988 Fax : 0183-304505 E-mail : info@jade-v.nl URL : www.jade-bv.nl 1. INTRODUKTIE

Nadere informatie

Handleiding RD5060 SPRAAKMODULE MONTAGE-INSTRUCTIES. RD5060 II /V6ip

Handleiding RD5060 SPRAAKMODULE MONTAGE-INSTRUCTIES. RD5060 II /V6ip Handleiding RD5060 II /V6ip RD5060 SPRAAKMODULE De RD5060 is een module die, in combinatie met een RD6201, boodschappen kan doorgeven naar semadigits of naar particulieren. In beide gevallen wordt gebruik

Nadere informatie

AT1G26-200. rev.0110. Toegangscontrole Module AT1G26-200. Handleiding. thinks outside the box!

AT1G26-200. rev.0110. Toegangscontrole Module AT1G26-200. Handleiding. thinks outside the box! AT1G26-200 rev.0110 Toegangscontrole Module AT1G26-200 Handleiding PRODUCT SPECIFICATIE Modelen AS-626M-200, AS-626S-200, AS-634-200, AT1G26-200 Opbouw Antivandaal Geborsteld aluminium behuizing Tot 200