Aanvraag Vergunning Wet milieubeheer. Zuidlob Wind B.V. io. Windpark De Zuidlob

Maat: px
Weergave met pagina beginnen:

Download "Aanvraag Vergunning Wet milieubeheer. Zuidlob Wind B.V. io. Windpark De Zuidlob"

Transcriptie

1 Aanvraag Vergunning Wet milieubeheer Zuidlob Wind B.V. io Windpark De Zuidlob Project: Windpark De Zuidlob Auteurs: Dhr. J.P. de Gooijer / Nuon Wind Development B.V. Referentie Nummer: /JdG/0510/Wm Datum: 14 mei 2010

2

3 INHOUDSOPGAVE DEEL1: AANVRAAG VERGUNNING WET MILIEUBEHEER 1. ALGEMEEN Aanvrager Correspondentie-adres Verzoek Beschrijving inrichting Eerder verleende vergunning Wet milieubeheer Samenloop met andere regelgeving NADERE OMSCHRIJVING VAN DE VERANDERINGEN Uitbreiding mogelijk toe te passen windturbines Onderlinge afstand windturbines; correctie positie 2 windturbines Spanningsniveau onderstation Lozing van hemelwater MILIEUEFFECTEN VERANDERINGEN Uitbreiding toe te passen windturbines Onderlinge afstand windturbines; correctie positie 2 windturbines Lozing van hemelwater... BIJLAGEN: A. LOCATIETEKENING VAN DE INRICHTING B. KARAKTERISTIEKEN EN TEKENINGEN MOGELIJK TOE TE PASSEN WINDTURBINES C. DESKUNDIGENVERKLARING WIJZIGING SPANNINGSNIVEAU ONDERSTATION D. NOTITIE SITUATIETEKING LOZING EN ZUIVERINGSTECHNISCHE MAATREGEL E. AKOESTISCH RAPPORT LICHTVELD BUIS & PARTNERS BV D.D. 12 MEI 2010 DEEL 2: AANVULLINGEN AANVRAAG VERGUNNING WET MILIEUBEHEER D.D. 30 JUNI EN 12 JULI AANVULLING AANVRAAG WET MILIEUBEHEER D.D. 30 JUNI AANVULLING AANVRAAG WET MILIEUBEHEER D.D. 12 JULI 2010

4 Notitie aanvraag Vergunning Wet milieubeheer Windpark De Zuidlob Aanvrager: Auteur: Datum: Referentie: tfiidlob Wind BV i.o. drs. J.P. de Gooijer 17 mei jJdGj0510jWm Aanvraag vergunning Wet milieubeheer ten behoeve van verandering Windpark De Zuid lob te Zeewolde. mei 2010

5 INHOUDSOPGAVE 1. ALGEMEEN Aanvrager Correspondentie-adres Verzoek Beschrijving inrichting Eerder verleende vergunning Wet milieubeheer Samenloop met andere regelgeving NADERE OMSCHRIJVING VAN DE VERANDERINGEN Uitbreiding mogelijk toe te passen windturbines Onderlinge afstand windturbines; correctie positie 2 windturbines Spanningsniveau onderstation Lozing van hemelwater MILIEUEFFECTEN VERANDERINGEN Uitbreiding toe te passen windturbines Onderlinge afstand windturbines; correctie positie 2 windturbines Spanningsniveau onderstation Lozing van hemelwater... 8 BDLAGEN: A. LOCATIETEKENING VAN DE INRICHTING B. KARAKTERISTIEKEN EN TEKENINGEN MOGELDK TOE TE PASSEN WINDTURBINES C. DESKUNDIGENVERKLARING WDZIGING SPANNINGSNIVEAU ONDERSTATION D. NOmIE SITUATIETEKING LOZING EN ZUIVERINGSTECHNISCHE MAATREGEL E. AKOESTISCH RAPPORT LICHTVELD BUIS & PARTNERS BV D.D. 12 MEI 2010 Aanvraag vergunning Wet milieubeheer ten behoeve van verandering Windpark De Zuidlob te Zeewolde. mei

6 1. ALGEMEEN 1.1 Aanvrager De aanvrager is: Zuid lob Wind BV i.o., contactpersoon de heer D. Monsma. Statutair adres: Winkelweg 59, 3896 LH Zeewolde, tel Tezamen met: 75 medeaanvragers. 1.2 Correspondentie-adres Zuidlob Wind BV Lo P/a WEOM BV Postbus AC Ede 1.3 Verzoek Deze notitie bevat het verzoek om vergunning ingevolge de Wet milieubeheer als bedoeld in artikel 8.1 onder b Wet milieubeheer: een vergunning voor het veranderen van de inrichting of de werking van de inrichting. 1.4 Beschrijving inrichting De vergunde maar nog niet opgerichte inrichting (zie paragraaf 1.5) bestaat uit drie lijnopstellingen met elk 12 windturbines met bijbehorende elektrische en civiele werken, waaronder ook een onderstation en de aansluiting op het elektriciteitsnet wordt begrepen. De 36 identieke windturbines hebben elk een vermogen van circa 3 MW. 1.5 Eerder verleende vergunning Wet milieubeheer Op 1 april 2010 is door Burgemeester en Wethouder van Zeewolde vergunning ingevolge de Wet milieubeheer verleend voor het oprichten en in werking hebben van de inrichting. De vergunning is binnen de Rijkscoördinatieregeling bekendgemaakt en ligt sinds 23 april 2010 ter inzage. 1.6 Samenl~op met andere regelgeving ~,,: Voor het oprichten van de inrichting is onder meer een bouwvergunning noodzakelijk. De bouwvergunning kan pas worden verleend nadat de planologische basis daarvoor is geregeld middels een Rijksprojectbesluit of Rijksinpassingsplan. Het Rijksinpassingsplan dat voorziet in Aanvraag vergunning Wet milieubeheer ten behoeve van verandering Windpark De Zuidlob te Zeewolde. mei

7 de bouwen het gebruik van de inrichting is vastgesteld op 25 maart 2010 en ligt sinds 23 april 2010 ter inzage. Voor de verandering van de inrichting zoals die in deze aanvraag is opgenomen is bouwvergunning vereist voor zover dat de bouw van windturbines betreft. Voor de overige veranderingen is geen bouwvergunning benodigd. De benodigde bouwvergunningen worden binnen de Rijkscoördinatieregeling gelijktijdig aangevraagd. Voor de verandering van de inrichting is een watervergunning benodigd, voor zover de verandering berekking heeft op de lozing van hemelwater vanuit het onderstation dat onderdeel is van de inrichting op oppervlaktewater. De benodigde watervergunningwordt binnen de Rijkscoördinatieregeling gelijktijdig aangevraagd. Op de procedures voor de uitvoeringsbesluiten ten behoeve van onderhavige inrichting is de Rijkscoördinatieregeling uit de Wet op de ruimtelijke ordening van toepassing. Aanvraag vergunning Wet milieubeheer ten behoeve van verandering Windpark De Zuidlob te Zeewolde, mei

8 2. NADERE OMSCHRIJVING VAN DE VERANDERINGEN 2.1 Uitbreiding mogelijk toe te passen windturbines De oprichtingsvergunning voorziet in het oprichten en in werking hebben van 36 identieke windturbines. Er is nog niet definitief gekozen voor een specifieke windturbine waardoor meerdere mogelijk toe te passen windturbinetypes in de oprichtingsvergunning zijn opgenomen. Verzocht wordt om nog 2 andere windturbinetypes toe kunnen te passen. De inrichting zal, ook na de verandering, blijven bestaan uit 36 identieke windturbines (dus van één type). Deze windturbines zijn net nieuw op de markt en daarmee state-of-the-art. Bovendien zijn deze windturbines naar verwachting uitermate geschikt om in onderhavige inrichting toe te passen gelet op de opstellingsvorm, tussenafstand en gemiddelde windsnelheid op ashoogte. In tabel 1 staan de karakteristieken van de 2 mogelijk toe te passen windturbines omschreven. In bijlage B zijn de tekeningen en technische beschrijvingen van deze windturbines opgenomen. Merk Type Vermogen (MW) Ashoogte Rotordiameter (m) vanaf (m) bovenkant fundering* Enercon El0l Alstom Ecotecnia Tabel 1: Mogelijk te plaatsen windturbinetypen en karakterisitieken * ivm het hoger aanleggen van de fundatie kan de bovenzijde van de fundatie maximaal 1,7 meter ) hoger liggen dan het omliggende maaiveld. Alle fundaties hebben wel dezelfde aanleghoogte t.o.v. NAP. Voor wat betreft eventuele milieueffecten zal deze aanvraag daar waar nodig de effecten per (categorie van) windturbinetype beschrijven. 2.2 Onderlinge afstand windturbines; correctie positie 2 windturbines De windturbines worden in de lijnopstellingen met een onderlinge afstand van ca. 405 meter geplaatst. De total~lengte van elke lijnopstelling bedraagt ca. 4,5 km. Bij het nameten va~' de onderlinge afstand van de windturbines in de 3 lijnopstellingen zoals vergund bleek dat één windturbine in de lijnopstelling aan het Nijkerkerpad zonder reden afwijkt van de regelmatige lijnstructuur waardoor de afstand tot de naastgelegen windturbines 368 en 352 meter bedraagt in plaats van 410 meter in de rest van de opstelling. Uit landschappelijk oogpunt is het gewenst lijnopstellingen met (nagenoeg) regelmatige tussenafstanden op te richten. De exacte locatie van windturbine N-08 in de lijnopstelling Aanvraag vergunning Wet milieubeheer ten behoeve van verandering Windpark De Zuidlob te Zeewolde, mei

9 Nijkerkerpad is daarom ten opzichte van de vergunde situatie met circa 42 meter opgeschoven binnen de lijnopstelling. De meest westelijk gelegen windturbine in de lijnopstelling aan de Rassenbeektocht CR-Ol) staat in de vergunde situatie op een afstand van ca. 415 van de naastgelegen windturbine terwijl de gemiddelde tussenafstand in deze lijnopstelling 398 meter bedraagt. Daarom is ten opzichte van de vergunde situatie windturbine R-Ol met circa 17 meter in de richting van windturbine R-02 verschoven. De nieuwe situatietekening is opgenomen in bijlage A. 2.3 Spanningsniveau onderstation Het onderstation zal bestaan uit een open schakeltuin, installatiegebouw en transformator. In de oprichtingsvergunning zijn de technische details van het onderstation gegeven. Daarbij is uitgegaan van transformatoren voor de omzetting van het spanningsniveau van 20 kv naar 150 kv. De interne parkbekabeling zal echter op een spanningsniveau van 33 kv functioneren. De transformatoren zullen daarom het spanningsniveau omzetten van 33 kv naar 150 kv. In bijlage C is een deskundigenverklaring opgenomen dat de oorspronkelijke technische gegevens en uitvoering van het onderstation daardoor niet wijzigen. 2.4 Lozing van hemelwater Het onderstation bevat transformatoren in de buitenlucht. In paragraaf 9.2 van de technische specificatie die in de aanvraag voor de oprichtingsvergunning is opgenomen is het volgende vermeld: De te plaatsen 150 kv /20 kv transformatoren worden in de buitenlucht opgesteld. Naar aanleiding hiervan is een NRB toets uitgevoerd. Volgens de NRB toets moet onder de transformatoren een vloeistofdichte opvangvoorziening (conform CURlPBV 44) worden aangebracht. Vloeistofdichte opvangvoorziening zal worden gebaseerd op de olie inhoud van de transformatoren, met een extra opvang van 10% (totaalopvangvoorziening 110%). In de vloeistofdichte opvangvoorziening zal een detectiesysteem worden aangebracht welke olie en water detecteert. Omdat in de weide omgeving geen riolering aanwezig is is voor dit systeem gekozen. Detectiemeldingen worden doorgemeld naar het bedrijfsvoeringcentrum waar contact wordt gezocht met een gecertificeerd bedrijf voor het leegzuigen en afvoeren van de inhoud opvangvoorziening. Verzocht wordt om het hemelwater dat in de bodembeschermende opvangvoorziening terechtkomt te lozen op oppervlaktewater met toepassing van een olieafscheider. In bijlage D is een notitie opgenomen met de situatietekening van de lozing en beschrijving van het toe te passen zuiveringstechnische werk. Het betreft een voorbeeldtekening, er is nog niet gekozen welke capaciteit zal moeten worden toegepast. Dat zal in overleg met de waterbeheerder plaatsvinden en als zodanig worden opgenomen in de watervergunning. Aanvraag vergunning Wet milieubeheer ten behoeve van verandering Windpark De Zuidlob te Zeewolde. mei

10 3. MILIEUEFFECTEN VERANDERINGEN 3.1 Uitbreiding toe te passen windturbines Geluid In overeenstemming met de systematiek zoals die in de aanvraag om oprichtingsvergunning is toegepast is onderzocht wat de gevolgen van de nieuwe windturbinetypes zijn voor de geluidbelasting op woningen van derden en het stiltegebied Horsterwold. Het akoestische rapport is opgenomen in bijlage E. Hieruit blijkt dat de geluidbelasting als gevolg van de inrichting bij toepassing van de 2 windturbinetypes aan de reeds vergunde normen kan voldoen. Daarvoor zijn bij bepaalde windturbines wel maatregelen nodig, zoals in het akoestisch rapport is opgenomen en uitgewerkt. Slagschaduwen reflectie Omdat het optreden van slagschaduw geen merkjtypespecifiek gevolg van windturbines is en de nieuwe windturbinetypes qua afmetingen overeenkomen met de in de vergunning opgenomen types, is aanvullend onderzoek niet uitgevoerd. De nieuwe windturbines komen immers nagenoeg overeen met de reeds vergunde windturbines Ecotecnia ECO 100, Vestas V112 en Repower 3.XM, die om redenen zoals in de aanvraag voor de oprichtingsvergunning opgenomen binnen de onderzoeksmarge vallen. Het optreden van slagschaduw in de omgeving wijkt niet af van de vergunde situatie. De f1ikkerfrequentie ligt bij deze windturbinetypes niet tussen 2,5 en 14 Hz. De rotorbladen van de nieuwe windturbinetypes zijn voorzien van een coating met antireflectielaag. Op deze wijze is er geen sprake van onaanvaardbaar hinderlijke lichtschittering door reflectie van zonlicht. Veiligheid De nieuwe windturbinetypes zullen net als de vergunde types voldoen aan de hoge veiligheids- en kwaliteitseisen die internationaal gelden en worden dan ook gecertificeerd door onafhankelijke keuringsinstellingen. De windturbines zullen voldoen aan de NVN norm enjof aan de IEC norm of diens rechtsopvolger. Bodem, flora en fauna, afvalstoffen De nieuwe windturbinetypes hebben geen van de oprichtingsvergunning afwijkende invloed op deze aspecten. 3.2 Onderlinge afstand windturbines; correctie positie 2 windturbines Windturbine N-OB in lijnopstelling Nijkerkerpad Het verschuiven van de windturbine in de lijnopstelling Nijkerkerpad vindt "in de lijn plaats". Daardoor verandert de afstand tot woningen van derden en het stiltegebied Horsterwold niet. Aanvraag vergunning Wet milieubeheer ten behoeve van verandering Windpark De Zuidlob te Zeewolde. mei

11 De akoestische gevolgen van de, gelet op de gehele lijnopstelling marginale verschuiving zijn naar verwachting verwaarloosbaar ten opzichte van de vergunde situatie. In de situatie na verandering kan en zal worden voldaan aan de geluidvoorschriften zoals opgenomen in de oprichtingsvergunning. Ook de gevolgen voor het optreden van slagschaduw zijn naar verwachting verwaarloosbaar zodat ook in de veranderde situatie geen mitigerende maatregelen nodig zijn om de omvang ervan te beperken. Windturbine R-Ol in lijnopstelling Rassenbeektocht De marginale verschuiving van de meest westelijke windturbine in de lijnopstelling Rassenbeektocht leidt tot een iets grotere afstand tot de woning Tureluurweg 58 te Lelystad. Voor de woning Nekkeveldweg 37 treedt effectief nauwelijks tot geen verandering in afstand op. In de situatie na verandering kan en zal worden voldaan aan de geluidvoorschriften zoals opgenomen in de oprichtingsvergunning. Ook de gevolgen voor het optreden van slagschaduw zijn naar verwachting verwaarloosbaar zodat ook in de veranderde situatie geen mitigerende maatregelen nodig zijn om de omvang ervan te beperken. 3.3 Spanningsniveau onderstation De wijziging van het spanningsniveau in het onderstation heeft geen enkel effect naar de omgeving. Aan de geldende normen en voorschriften voor transformatorstations zal worden voldaan. 3.4 Lozing van hemelwater De gevolgen van de lozing van hemelwater naar het oppervlaktewater heeft geen gevolgen voor de leefomgeving. Eventuele gevolgen voor het oppervlaktewater worden in de procedure voor de gelijktijdig met onderhavige aanvraag ingediende aanvraag om watervergunning. Ondertekening: ( Datum: --,-' =J,>--~5''---...I,.I...".O,,--_ Datum: l "'; ( (,) Handtekening aanvrager: Handtekening gemachtigde: drs. J.P. de Gooijer Aanvraag vergunning Wet milieubeheer ten behoeve van verandering Windpark De Zuid lob te Zeewolde. mei "\ )

12 A. LOCATIETEKENING VAN DE INRICHTING

13

14 B. KARAKTERISTIEKEN EN TEKENINGEN MOGELDK TOE TE PASSEN WINDTURBINES

15 m "... ' ' 0 0::: 0 '- -+-' c Q) u 0 I / /./ -~ /'"... / "- / \ "C) \ <s>" I \ I \ I \ I I ~ T \ ~ I I I \ / I I \ / r ~ '-... "- I I '- Q) -+-' - '" " """ I - c Q) I u ' ' 0 ' ' '-" I r «=r= I ~l \ I rr i """ I / I ~./ / / A LSTÖ>M: A I B I 145 I 155 I ST JA JA Added information tower loom / Anadidos datos torre de loom EGC JA JA Added Alstom format / Anadido formato Alstom I POWER MCS OT LF Modificodo n' producto 022 (antes 019). WIND MJS MB LF -- Mad. Vers. Date(DMY) Draw. Check Appr. Change descripuon General tolerances: ±O.5% Material: -- Scale Assembly: -- Linear dimensions (m) Surface treatment: -- ~ ISize: A4 1:1000 Weight (kg): -- Painted: -- E3 -ISheet: 1/1 Product: 022 Group: 00-0 WINDTURBINE ECOTECNIA 110 Drawing Nr: Article: AEROGENERADOR ECOTECNIA vers.- The Information contalned hereln is AL.STOM proprletary information and has been dlsclosed In confldence. Any usa, dlsclosure or reproduction of this information without Aistom's written permission Is a vioiation of AL.STOM's and Ecotècnla Energfas Renovables. S.L. All rlghts reserved. Mod. 00

16 I POWER WIND Alstom Wind, s.l.u. Roe Boronat, Barcelona, Spain Phone: Fax: A LSTO)M TECHNICAlOESCRIPTION FRM EN _ R03 05T-0237 Rev. 03 TITlE: ECO General description Author: Checked by: Approved by: A. Fernández s. Sanesteban F. Schuon REVISIONS Rev. Date Description of changes 00 08/10/2009 Emission 01 10/02/2010 General changes 02 17/03/2010 General changes -Serie /05/2010 Paragraphs 5/6/7 Modifies pages All pages All pages Author AF AF AF AF The technical and other data contained in this document are provided for information only. Alstom reserves the right to revise or change this data at any time without further notice. Aistom. Alstom, the Alstom logo and any alternative version thereof are trademarks and service marks of Alstom. The other names mentioned, registered or not, are the property of their respective companies.

17 DST-0237 Rev 03 TABLE OF CONTENTS 1. Aim Scope General description General ambient design criteria Electrical grid requirements Active/reactive power control Low voltage-through Tower & foundation Nacelle Hub... S 3.6 Blades Pitch control system S Yaw system Power train layout Gearbox Electrical system Generator Power cabinet Converter Transformers (OPTIONAL) MV switchgear (OPTIONAL) Control system AlM This specification is a general technical description of the ECD 110 wind turbine. This document includes general information of the wind turbine components. The description of main components shown in this document is only informative and it might change according to production requirements without further notice. 2. SCOPE wr Remarks EC062 D D -- EC074 D D -- ECOS6 D D -- ECOso D D -- ECOSO 2.0 D D -- EC0100 D D -- ECOll0 ~ D From51 5. Scada system SCADA communication features Communication with the WT Control system Communication with the Substation Data Acquisition System (OPTIONAL) Communication with the meteorological mast (OPTIONAL) SCADA external accesses / OPC Server Wind farm connectivity External wind farm connectivity Internal communication connectivity Maintenance and After Sales service Certification /17 EeG General desmptlon

18 DST-0237 Rev GENERAL DESCRIPTION The ALSTDM ECD 110 is a new generation of large, high power turbines for onshore use, setting a new standard for Clean Power. The ECD 110 owes its name to its 110 m rotor diameter, one of the largest rotors available today, which permits to capture even greater amounts of energy. Moreover, its rated power of 3.0 MW allows for a higher energy yield. The wind turbine has been designed following Class III-A specifications of the standard IEC It is suitable for sites with a mean annual wind speed up to 7.5 mis and an extreme gust speed with a 50 year repetition frequency of 59.5 mis (higher than defined in the normative). Fig. 1- The ECD 110. The design of ALSTDM wind turbines are based on the ALSTOM PURE TORQUE, which is unique in the industry. Rotor deflection loads are transmitted directly to the tower whereas only torque is transmitted to the gearbox. As a consequence the gearbox lifetime is extended. Safety and ergonomics have been important drivers in the design of this wind turbine. The technicians can access the rotor from inside the nacelle. Increased dimensions allow maintenance operations to be performed safely and easily. Wind turbine maintenance operations are faster and safer than ever. Fig. 2- ECD 110 general dimensions - Tower 90 m. ECO General description 3

19 : : : : j -t ~ ~ >... WIND SPEED POWER [Kw] POWER COEFF CP THRUST COEFF. Power [kw] I,... ~ ~ : : : : ,28 0, : :--7~ --: i ,36 0, ,41 0, ,43 0, , ,44 0,77, - -: , , : , : ' ,44 0, ,,,, ,41 0, , : , , , ,36 0, ~ } "" I ,29 0, I ,23 0, , 025, 200 f á : : : o ,15 0, Wind speed,, Fig. 3 ECD 110 power curve [mis] ,10 0,13 (Density = kg/m 3 Turbulence intensity = 10%). ~ Num. 10: ' g ,08 0,11 -g /'l) ;:+d' Q) = ,07 0,09 ~ ~ :ie 3 ' ,06 0,08 [ ~ ~ Q) c!:!:... /'l) ,05 0,07 ~ VI ~ :ie ,04 0,06 {g 'ë o ~ C "C _. ~ ,04 0,05 ~ ~ 3 I Table 1 The ECD 110 power curve. ~. ~. ~ Q) Q) ,03 0,04?T 5. ~ ~ 0 ::T ,03 0,04 (Density = kg/m 3 Turbulence intensity 10%). ~ ~ ~ rn _.

20 D5T-0237 Rev 03 A LSTO )M GENERAL SPECIF ICATIONS Model ECO 110 Wind Turbine Class according to IEC/EN Position of rotor relative to tower Hub height 1) Rotor diameter III -A Upwind 90m 110 m Rotor swept area 9417 m 2 Rated power Rated rotor speed (L5S) Rotor speed range (LSS) Tower type Foundation standard type 1) 3.0MW 13.7 rpm rpm 90 m tubular Concrete octagonal foundation slab and concrete octagonal pedestal. Colour RAL 7035 Control system Variabie speed and pitch control Table 2- ECD 110 general specifications. 1) These characteristics are guiding values and could be submitted to changes (depending local conditions). Table 3- ECD 110 main weights. For more information please contact our Sales department. OPERATING DATA Mean annual wind speed (maximum) Rated wind speed 7.5 mis 11.5 mis Reference wind speed (avg. 10') 42.5 mis 1) Extreme gust speed (IEC) 59.9 mis 1) Cut-in wind speed Cut-out wind speed (60OS average) Instant cut-out wind speed (3 s) Vertical wind inciination throughout the operative life ofthe wind turbine (IEC) Rated power Power density Temperature range for normal operation 2 ) Extreme temperature range (turbine stopped) 2) 3 mis 25 mis 34 mis MW 3.15 m 2 I kw -10 to C -20 to C Lightning protection IEC Level 1 Table 4- ECD 110 operatmg data. 1) ECO 110 IS consldered as IEC Class III in terms of annual average wind speed (V ave ) ' However, the reference wind speed (V ref) accords to I EC Class 11. 2) For more details on temperature ranges please contact our Sales department. 3.1 GENERAL AMBIENT DESIGN CRITERIA The wind turbine has a design lifetime of 20 years according to the lee In the case that the site environmental differ from the operational data (see table 4) please contact with our commercial department. For more details please ask for the specific documentation. 3.2 ELECTRICAL GRID REQUIREMENTS The wide application of wind energy, even in wide isolated grids, needs modern wind turbines to fulfill Transmission System Operators (TSO) requirements and provide enough transient stability to overcome grid regulations concerns. New grid codes have been introduced, establishing capacity limits that control the active power output of wind farms, as weil as their power factor. Also, many system operators in Europe nowadays require wind turbines with a higher potential to sustain grid transients. In response, ALSTOM designs its wind turbines to provide dynamic control of active and reactive power and to supply continuity against voltage drop downs. The wind turbines fulfill most international grid connection requirements - frequency and voltage control ACTIVE/REACTIVE POWER CONTROL ALSTOM MW-class wind turbines have the capability to control the active power output with a rapid response. The reference value can be adjusted in order to limit the output at that particular level. Smooth transition from the default mode to operation with limited output prevents unnecessary mechanicalloads from being transferred to the structure. Our wind turbines can deliver/control their reactive power in the range from 0.95 lagging to 0.95 leading for the voltage range of ±10%. ECO General descnptlon 5

21 OST-0237 Rev LOW VOLTAGE-THROUGH s'ëëriön 5... ':....:::..:.:...::... Dur wind turbines continuously supply power during voltage drop down according to International grid codes. The wind turbines comply with most of the International regulations. No disconnection from grid. No consumption of active or reactive power. Power production proportional to the voltage. Reactive power generation to help the grid recovery. SECTION 4 SECTION ::.:::: r 1 SECTION 2 SECTION _ USA FEIl< CANADA.!lYDRO QUEa EC BRAZIL ONS france ITALY UNITED K' NGOOM Fig. 4- International Low Voltage requirements. 3.3 TOWER & FOUNDATION _ Ride SPAIN GERMAh"Y EON AISlOM WIND Through ALSTDM 90 m tower has been designed allowing the installation in almost all soil types with minimum extra cost. The five sections are made of steel plate. The flanges joining them are bolted and welded on each extreme. Along the tower are placed different platforms for the surveillance and maintenance works. In figure 5 you can find a picture that represents the tower structure in sections and the location of the most important electrical components remaining with an invariant disposition for all cases. PLATFORMS: Lower platform Protection platform Section 1 flanges platform Section 2 flanges platform Section 3 flanges platform Section 4 flanges platform Upper platform Fig. 5- ECD m tower. TOWER Type description Material Foundation standard type Tower base diameter Steel tower top diameter Corrosion class, outside (EN ) Color T90 ELECTRICAL COMPONENTS: Switchgear Lifting appliance control cabinet PB cabinet 90 m tubular Steel Concrete octagonal foundation slab and concrete octagonal pedestal. 1) 4.5 m 2.85 m C4 RAL 7035 Table 5- The ECO m tower main features. 1) These characteristics are guiding values and could be submitted to changes (they depend on local standards and soil conditions). 6/17 ECD General desmptlon

22 DST-0237 Rev 03 A LSTO )M 3.4 NACELLE The nacelle cover is made of Glass Reinforeed Plastic (GRP). lts housing is made up of three independent elements. Lateral housings provide extra space to install the power transformerl the inverter and control cabinetsl while providing easy access for maintenance technicians. Placing the power transformer in the nacelle reduces the power lost during transmission from the generator to the transformer. The nacelle main frame comprises three blocks: The front frame is a conical component made by cast ironl carrying the hub through the main bearings. It directs via the central frame the rotor loads into the tower. The front frame is bolted directly to the centra I frame l also made by spheroid cast ironl which supports the gearbox 1 the three guide supports and the four motors of the yaw system. The rear frame l made of welded structural steet is bolted to the central frame and supports the generatori the hydraulic master unitl the converter and the transformer. The nacelle contains the internallooo kg service crane. An opening in the floor provides access to the nacelle from the tower. Other equipment on the nacelle roof is the lightning arrester l the wind sensors and the beacon lights. 0 Pitch system ct ft e Rotor Front main frame Central main frame e 0 Main transfarmer e ct e Rear main frame Wind wane, anemometer, low intensity beacon and lightning arrester. Gearbox Generator Fig. 6- ECO 110 nacelle frame. On this image the most important components in the nacelle are described_ ECO General descrtption 7

23 DST-0237 Rev 03 E m -i A LSTOIM ecotëcnia 14.6 m Fig. 7 Nacelle dimensions. 3.5 HUB The hub is made by cast iron with three joint flanges for the pitch control bearings and three access points for maintenance tasks. The central conical part houses the rotor bearings. The ECD 110 design allows the technicians full internal access to the hub directly from the nacelle. Fig. 8 - ECD 110 hub deflector. 8/17 ECO 110. General descnptlon

24 DST-0237 Rev 03 A LST(ö)M 3.6 BLADES The blad es are manufactured according to the prebending concept. This concept means that the blade is created 50 th at it reaches the optimal shape wh en submitted to the wind loads. Another advantage of this concept is th at it allows lighter blades and a large swept area, crucial for the annual production of the wind turbine. The tip design enables the possibility to obtain a good balance between noise generation and performance. 3.7 PITCH CONTROL SYSTEM The pitch control system is made by a crown wheel supported by bearings and an electrical actuator. Each blade has an independent pitch system with its own emergency battery package. The main wind turbine braking system is also based on pitch control. The existence of independent pitch systems for the three blades, including one autonomous uninterrupted power supply in each blade, maximizes the safety factor of the wind turbine: in the event of a failure of one pitch system, the wind turbine is still capable of braking. The next tables resume the most important mechanical and electrical characteristics of the Pitch System. GENERAL SPECIFICATIONS Boxes/Blade Location Battery Management Actuators Encoder Lubrication Inverters Others 2 (Driver+Batt.) Pitch system has fixed position inside the hub Includes remote condition monitoring DC Compound Motor SSI Encoder+Resolver Combination analyzed by the Inverter Power supply of Lubric. pumps; Commands over Device Net Communication Includes remote control and monitoring Redundant Encoder Table 7- ECD 110 pitch systems mechanica I main features. Fig. 9- ECD 110 blades. The next table resumes the most important characteristics of the blades: BLADES Length 53.2 m Maximum cord 3.95 m Blade surface area (1 blade) 1) 129 m 2 Weight (approx.) 12 tons Table 6- Blades main features. 1) Projected surface area. Pitch gearbox Battery box Encoder Axial box Fig Elements of the pitch control system. ECO General descrjptlon 9

25 DST-0237 Rev YAW SYSTEM 3.9 POWER TRAIN LAYOUT The principle of the Yaw System is the same used in other models - like ECD 74, ECD 80 & ECD and has the reliability proven by them, but integrates new improvements in axial and radial guiding. The sliding bearings are easy to maintain without the need of cranes. The yaw system is composed by: The yaw system (self): one crown and four pinions (with 4 motors), the guiding system: with 3 passive guiding pads, and the brake system: that includes 4 hydraulic brake callipers. The ALSTOM PURE TORQUE, is designed to transmit the torque loads from the rotor to the drive train, whereas the rotor bending loads (non useful loads) are transmitted through the main frame to the tower structure. The hub is supported directly by the mainframe on two bearings, whereas the gearbox is fully separated from the supporting structure. This design avoids the introduction of rotor bending loads to the gearbox. This is proven with more than 10 years of experience since its introduction in the ECD 44 wind turbine. The four motors and the planetary type gear reducers drive by variables frequency. The next table resumes the general values of the yaw system. GENERAL SPECIFICATIONS Number of motors 4 Reduction ratio Pin ion / crown wheel ratio 1:17.36 Table 8- ECD 110 yaw system ma in features. Fig ALSTOM PURE TORQUE The green arrows represent the torque farces and the red arrows the wind bending farces. The fixing of the rotor deflects all bending loads to the tower and only the useful torque loads are transmitted to the drive train. Yaw crown top view Yaw crown 8rake callipers Gear motor., Guiding pad Central frame Fig ECD 110 aw system, general view. 10 / 17 ECO General descrlptlon

26 DST-0237 Rev GEARBOX The wind turbine gearbox increases the relatively slow speed of the rotor to the speed required by the generator ELECTRICAL SYSTEM The following sections will explain the main electrical components in the wind turbine generator. The main electrical components are: The gearbox is formed by two planetary stages and one parallel stage. Gearbox is the complete assembly of gears, shafts, bearings, housing, seals, lubrication system and associated components. Generator Power cabinet Converter Transformer MV Switchgear The gearbox is placed next to the centre of the tower, between the Low Speed Shaft (LSS) and the generator. The connection to the LSS is achieved by a bolted flange and the connection to the generator by an elastic coupling-hss (High Speed Shaft). The gearbox is fixed to the central cast iron main frame by means of two torque arms and its gearbox supports (rubber-metal elements). Due to the special bearings arrangement and layout, the LSS and gearbox are only loaded by main torque (Mx). The next table shows the gearbox main features: GEARBOX Type Input / Output speed 2 planetary stages + 1 helicoidally stage 13.7 rpm (input) /1800 rpm (output) Nominal gearbox ratio 1: Support Table 9- ECD 110 Gearbox main features. Elastomeric pads (Silent Blocks) The main electrical concept from our wind turbines is to separate the auxiliary services from the main electrical components. FOll.OWlNG wr I'IYWlNDfARM line Fig. 13- ECD Basic electrical system diagram. 5WlTCHGfAR The auxiliary services take care of the elevator, lig hts, outlets, sensors, heating, cooling, yaw, pitch and control systems. Some of these have an UPS for emergency cases. ECO General description 11

27 DST-0237 Rev GENERATOR The ECO 110 generator is an asynchronous variabie speed doubly fed induction generator (DFIG), i.e. two multiphase windings sets, one at the stator and one at the rotor. The rotor side is control by the converter. One of the most important advantages of this type of generators is that, transitory, they can allow mechanical torque over the full load torque without the lost of synchronism. The next table shows the most important specifications of the generator used in the ECO 110. GENERATOR Type Rated power Speed range Rated generator speed Stator voltage Rotor voltage Frequency Refrigeration OFIG 3200 kw rpm 1800 rpm 1000 V 760 V 50 Hz Water-Air POWER CABINET The power cabinet is designed and manufactured by ALSTOM. This cabinet contains the circuit breaker that protects the stator of the generator and the contactor, which it is controlled by converter and allows the connection of the generator to the grid and start producing energy. The main characteristics are exposed on the next tabie: POWER CABINET Manufacturer Stator contactor Circuit breaker Characteristics ALSTOM 2050A 2000 A Cabinet frame Table 11 ECD 110 power cabinet main features. Table 10 ECD 110 generator main features. Fig. 14 ECD 110 generator. 12/17 ECG General descnptlon

28 05T-0237 Rev 03 A LSTC lm CONVERTER The converter is located in the nacelle. The converter will help to limit the active power and regulate the reactive power to a desire set point. The converter carries out the control of the generator rotor and adapts the generated energy to a suitable energy to be fed to the grid according to grid codes. The features of the converter depend in high measure of the type of semi-conductors used in its construction. The ECG 110 converter is a Back-toback AC-DC-AC based in IGBT technology. lts mam characteristics are exposed on the next tabie: CONVERTER Type Technology Cooling system Characteristics Back-to-back AC-OC-AC. IGBT Water cooled Active crowbar +OC chopper. Improved LFRT performance Table 12- ECD 110 converter main features TRANSFORMERS (OPTIONAL) The transformer allows adapting the wind turbine voltage to the wind farm voltage. The ECG 100 presents the transformer in the nacelle. The main function of this is to step-up the wind turbine voltage to the wind farm voltage. Table 13 describes the most important technical characteristics of it. MAIN TRANSFORM ER (IN NACELLE) Voltage (customizable) Power Type Losses Cooling system Maximum dimensions (LxWxH) Maximum Weight 1000 V; 690 V ; 400 V; 20/30 KV (customizable) 3500 kva Liquid Po = W; Pk = W KN (ester) 3.00 x 1.08 x 2.09 m 6.5 Tn Table 13- ECD 110 main transformer features. Fig. 16- ECD 110 main transformer. Fig. 15- ECD 110 converter. ECG General descriptlon 13

29 DST-0237 Rev MV SWITCHGEAR (OPTIONAL) The Medium Voltage Switchgear is located in the tower base. It protects the wind turbine against over currents, short circuits and ground fails. Some of the possible configurations are: One incoming feeder & one outgoing feeder (with and without disconnection). One incoming feeder & two outgoing feeders (with and without disconnection). End of line. 4. CONTROL SYSTEM The control system of the ECO 110 is based on the GALILEO platform developed by ALSTOM. It is a decentralized system that implements the regulatory characteristics already used for previous platforms but provides major additional advantages. The next table shows the most important characteristics of the Switchgear: SWITCHGEAR General Highest voltage for the material (customizable) Rated frequency Rated current Insulation level (rated freq.) Insulation level (lightning impulse) SF6 fully insulated, metal enclosed, lifetime sealed stainless steel tank 24/36 kv 50/60 Hz 400/630 A 50/70 kv 125/170 kv Options Feeder switch, motor switch, surge arrester. Table 14- ECD 110 switchgear main features. - CONTROL SYSTEM (in control cabinet) Generator box Inverter cabinet Power cabinet Block 1 cabinet Aux. pitch box cabinet Axial box Batteries box Deflector box Fig. 17- The Galileo System: the control system of the ECD 110. s. SCADA SYSTEM ALSTOM developed its own SCADA (Supervisory Control And Data Acquisition system), based on more than 25 years of wind turbines maintenance. The monitoring system consists of a set of electronic components, computer and infrastructure, oriented to the transmission, processing and presentation of operation data of the facility. The goal of the monitoring system is to make the information gathered in the farm available to the personnel responsible for the operation of the wind farm and provide real time data and historical data for analysis of the operation. Additionally it allows proper monitoring of the plant from the operations building, either from the farm operations centre or from remote sites through the use of data communication systems. 14/17 Eea General descnptlon

30 DST-0237 Rev SCADA COMMUNICATION FEATURES The SCADA system allows the communication with different components. The next diagram shows a schematic SCADA communications diagram. According to the communications diagramj the SCADA System communicates in all cases with the control system from each wind turbinej and optionallyj with the control substation and/or a meteorological mast. Data structure is according to I EC standard (Communications for Monitoring and Control of Wind Power Plants - Information model). Historical data for ten minutes and system-component alarms are stored in a SQL Server database. Data communications are done by means of: COIVIUNIUTlON wmt THE WT CONTIOL SYSTEM (STANOARO) CO... UNlamoN wmt THE o.aa ACQUISITION SYSTEM SUISTlll'lON (OPTlONAl) COIiIMUNiCATION wmt MITIOIOL05ICAL MIST (OpnONAl) _ G.lileo o Windf.rm., (ontrol room., Data acquisition system substalion Celisroom., Metm.st OPC DA 2.0 for instantaneous data. Web Services to recover historical data and alarms and additional information attached to such alarms. o Fig. 18 SCADA communications diagram COMMUNICATION WITH THE WT CONTROL SYSTEM As standardj SCADA provides remote access to the wind turbine data: the generated powerj rotor rpmj electrical dataj main components temperaturesj wind conditions and wind turbine statusj among others. The values are displayed in real time. For more information please refer to "4. Control System IJ COMMUNICATION WITH THE SUBSTATION DATA ACQUISITION SYSTEM (OPTIONAL) SCADA also enables the wind farm active/reactive powerj voltage and frequency control. For th at purposej the installation of a power grid analyser device with a specific hardware called ANEMONAX is needed. This hardware is the interface between the SCADA and the substation components. ECO General descrtptlon 15

31 DST-0237 Rev COMMUNICATION WITH THE METEOROLOGICAL MAST (OPTIONAL) SCADA enables the integration of a meteorological data acquisition system. ALSTOM wind farms are provided with the CAMPBELL data-logger. Optionally other data-loggers can be integrated. In genera" ALSTOM offers the option to perform the integration, installation and commissioning of the following equipments: Met mast Sensors Sensors supports Deck-house Data-logger Other accessories 6. WIND FARM CONNECTIVITY 6.1 EXTERNAL WIND FARM CONNECTIVITV To guarantee the operation and maintenance services, ALSTOM offers a remote connectivity system with the wind farms. Additionally, ALSTOM offers communications network integration with the customer or third parts by means of standard connectivity models (connectivity models can also be customized). Usually, wind farm data requires remote access. For that purpose the networks must be integrated in accordance with ALSTOM before agreed connectivity model. The data will be sent through 0 PC 2.0 servers integrated on the wind farm SCADA system SCADA EXTERNAL ACCESSES I OPC SERVER SCADA access is done by means of a web browser with Internet connection. Previous installation of a local application is not necessary. Based on OPC Server DA 2.0 SCADA issues all wind farm variables of the wind farm, the met mast as weil as the values calculated from SCADA itself. SCADA GENERAL SPECIFICATlONS: Object Oriented According I EC Multi-Ianguage OPC Server Standard database (SQL Server) Friendly GUl Grid integration Met mast integration Customizable stored historical data (years). IMPORTANT NOTICE: SCADA is typically customized on each wind farm. For more and binding information please contact ALSTOM Wind Sales Department. Network communiciition flow (lan Al5TOM) (LAN CUSTOMER) Fig. 19- Wind farm connectivity diagram. 6.2 INTERNAL COMMUNICATION CONNECTIVITV OPERATION & MAINTENAHCE SERVICES CUSlOMER ANOIOR THIRD PARTY All communications inside the wind farm are achieved by means of an Ethernet 100 Mbps network, whose infrastructure is mainly made of optical fibre. This network features many management and redundancy characteristics. As examples: connexion of wind turbines in redundant rings, priory's traffic, remote diagnostics, and so on. possibility of 16/17 ECO General descnptlon

32 05T-0237 Rev 03 A LSTO }M 7. MAINTENANCE AND AFTER SALES SERVICE The overall aim of the ALSTOM Maintenance Services is to ensure the optimum working order of wind turbines throughout their working life, so that they meet client expectations insofar as expected performance and reliability. A wide and flexible portfolio of services ensures adaptability to any customer need. All maintenance actlvities follow the guidelines established by the ALSTOM Quality System, which is certified according to the ISO 9001 Standard and with the company's Occupational Risk Prevention System. 8. CERTIFICATION All ALSTOM's wind turbines are certified according to IEC-EN standards by international organizations recognized to issue IEC-WTOl Type Certificates. These standards include the inspection of the assembly, fullscale testing of the blades and load, as weil as performance and load measurements. The power curve, emitted noise and power quality are measured by independent testing laboratories and are available to our customers. As decentralised units, the Operating and Maintenance areas supervise and operate the turbines in real time, programming, implementing and controlling the preventive and corrective maintenance actlvities. Preventive activities also includes predictive operations in order to assure and enhance reliability performance. The Alstom Wind spare parts management ensures the guarantee of spares parts on site and an available stock of critical components in the warehouses. Technical expertise is managed in different levels, form the field specialists to the area experts and the Alstom Wind Reliability Department. A double flow bottom-up and up-bottom of the information ensures knowledge sharing and quick reactions. ALSTOM puts its clients in direct contact with the Maintenance organization; a Key Account Management structure ensures quick and homogeneous information. In evenings and night time, when there's no physical presence of technicians on site, the Alstom Wind Control Centre monitors remotely the wind turbines to remotely reset alarms and dispatch on-call teams. ECO General descnption 17

33 l~ A e c ~ 8- El 6 '6.,,-+- / 1 I. n Ol Ol 5:6 1: Ol \: Ë~ Ol _ Ci e 5 '" I I LJ * \... '-... I -1- c DI V/A c 0 :g '0 C '0 ~ C oe is Cl.~ _ 0.E ~ I Ol - ë- ol'! ~~ :Ë~ ~~ ~:9 ~ Ol "-'" ~::2 00 "-'" E Projeklbezogene Angaben project spedfic data I Projekt I projed: Getdndehóhr! Ober NN I grou"id helght cbove sea leveli Gesalllthöhe Ober ~ I talm helght above sea level: Optlcnen I aplions: IE G)~':~;~';:: I night liklii<ng: ~ CD :2'0.~ ES ~~ ID Ol _ Cl fi [.c: _ '" 0 g' g r ~ u.c:", - Ol.bl'O i~ I Togeskenuelr:Mung I daylight mar1dng: welles BUfzllcht mit Sk:hfweltenreduzlenJng whlte flashlight wifh visiliuty redjdim r:~:::~~~i= <RAL 7038) I 611 red (RAL 3020) grey rolor blade <RAL 7(38) G)~:~auI~~~ ~~~'7~~ RAL Je 6m long I red/grey/red (RAL 3020 I RAL 7038 I RAL everv I dayllgrt marklng: Farbfetd RAL 3020 I colou" field RAL 3020 CID Nachlkerme/ctYl.lng/nlght markll'lg= HlrtdQmlsfauer auf jeder TI.JntQChsa 10 COl.--=.... obstrucilon fh on every 'ower axis 10 CD...=-... A ï:5i.~, ~ ~~-~I'IF -,:-:-,... ~:5'::.::.-; ENERCCJN GmbHl=~=-'" 1= -I E=:~:'~- t 102ti09 Ansicht 6etonferilgteKlurm ll.111idzlon _ Pal E-101 E1/BF/96_ --"""" WRO-T"" I~ I==;

34 ~ENERCON /IIIIJttI ENERGY FOR THE WORLD ENERCON WEC Characteristics E-101 page 1 of 1 WIND ENERGY CONVERTER CHARACTERISTICS E-101 Rotor Type E-101 Rotor diameter 101 m Swept area 8012 m 2 Power regulation Pitch RPM 6-14,5 min- 1 Cut in wind 2,5 mis Cut out wind mis Survival wind speed 59,5 mis I Gear Box Blades Manufacturer Blade length Material Lightning protection I No gearbox ENERCON 48,5 m GRP (Epoxy) included Generator Manufacturer ENERCON Nominal Power 3000 kw Type (model) Synchronous, direct-drive ringgenerator Protection classification lp 23 Insulation class F Yaw System Type Yaw control Yaw rate Controller Manufacturer Type Grid connection Remote communication UPS electrical motors Active (based on wind vane signal) 0,5 /sec ENERCON microprocessor Via ENERCON inverter ENERCON Remote Monitoring System included Braking System Aerodynamic brake - three independent blade pitch systems with emergency supply - rotor brake - rotor lock, locking at 30 Tower Hub heights Tower Design Wind Class 99 m Prefab concrete IIA Sourees: Design Assessment by ENERCON GmbH. All rights reserved. Created/Date: M. Lüninghöner Checked: AH/09/2009 Dpt. : SL_HB Approved: SL_HB_WEC Characteristics_E-101_RevOOO_eng- Revision: 000/ Reference: eng.doc

35 i(i ENERCON Technical Data E-101 l'iiit# ENERGIE FOR DIE WELT 3000 kw ENERCON GmbH Dreekamp Aurich T elefon: Telefax: Rated Power: Rotor diameter: Hub height: 3000 KW 101m m Turbine concept: Gearless, variabie speed, variabie pitch control Rotor Type: Direction of rotation: Number of blades: Swept Area: Blade material: Rotation speed: Pitch control: Drive train with generator Hub: Mean bearings: Generator: Grid feeding : Upwind rotor with active pitch control clockwise m 2 Fibreglass (epoxy resin); Integrated lightning protection variabie, rpm ENERCON blade pitch system, one independent pitching system per rotor blade with allocated emergency supply Rigid Dual-row tape red / single-row Cylindrical roller bearings ENERCON direct-drive synchronous annular generator ENERCON converter I Power Curve E-101 (Standard Air Density) \" ! J A. I I I A /' j 1/ Wind Speed v in Hub HeigIrt [mis) I Breaking system: Yaw control: Remote monitoring: 3 independent blade pitch Systems with emergency supply gung Rotor brake Rotor loek active via adjustment gears Load-dependent damping ENERCON SCADA Power Coefficient E-101 (Standard Air Density) : ~ i.~ i Go U 0.20 I A Wind SI>eed v in HlII> Height [mis] Original Details: Compiled: K. Koch / Approved : S. Lütkemeyer Ltd. Nr. : 002 Revision Date : 002 : Seite 1

36 C. DESKUNDIGENVERKLARING WDZIGING SPANNINGSNIVEAU ONDERSTATION

37 ',".:.,. Page 1 of 1 SERVICES Memo To : J. de Gooijer Dale : 3 mei 2010 From : Kfijnstra, A. Tel. : Subject : Spanningsniveau Fax: Project : Windpark de Zuid lob Ref.nr. : Copiesto : J. Timmermans In deze memo een toevoeging op de Technische Specificatie van het onderstation van windpark De Zuidlob (doc.nr.:tep1432.a.r001/jvw). In dit rapport wordt 20kV als spanningsniveau voor windpark opgegeven. Gezien het te transporteren vermogen zal het spanningsniveau van het park 33kV zijn. Dit betekent dat overal waar in het rapport 20kV staat, dit gelezen moet worden als 33kV. Hetzelfde geldt voor de bij het rapport behorende tekeningen in de bijlage (hoofdstuk 11). De verandering in spanningsniveau heeft geen gevolgen voor de in de specificatie aangegeven normen en voorschriften zoals opgenomen in hoofdstuk 7 van de technische specificatie. Daar zal ook bij het gewijzigde spanningsniveau aan worden voldaan. Emmtec Services bv Onderdeel van de Nuon-groep.~~ \VI ~.!!!'.!!1!!.!!'O ISO 11001:2008 Engineering 1e Bokslootweg 17 Postbus CA Emmen Nederland Tel. ;.31 (0) Fax +31 (0) Memo 20 nsar 33kV In rapport Liendon 3064 Ver. 1.0

Introductie in flowcharts

Introductie in flowcharts Introductie in flowcharts Flow Charts Een flow chart kan gebruikt worden om: Processen definieren en analyseren. Een beeld vormen van een proces voor analyse, discussie of communicatie. Het definieren,

Nadere informatie

THE WORK HET WERK HARALD BERKHOUT

THE WORK HET WERK HARALD BERKHOUT THE WORK During the twenty years of its existence Studio Berkhout has evolved into the number one studio specialized in still life fashion photography. All skills needed for photography and styling, including

Nadere informatie

Activant Prophet 21. Prophet 21 Version 12.0 Upgrade Information

Activant Prophet 21. Prophet 21 Version 12.0 Upgrade Information Activant Prophet 21 Prophet 21 Version 12.0 Upgrade Information This class is designed for Customers interested in upgrading to version 12.0 IT staff responsible for the managing of the Prophet 21 system

Nadere informatie

General info on using shopping carts with Ingenico epayments

General info on using shopping carts with Ingenico epayments Inhoudsopgave 1. Disclaimer 2. What is a PSPID? 3. What is an API user? How is it different from other users? 4. What is an operation code? And should I choose "Authorisation" or "Sale"? 5. What is an

Nadere informatie

Mounting ceiling & wall

Mounting ceiling & wall 5 / profile 34 bending radius R 15*) (1015) R 20 (1015) R 30 (1015) R>80 (1018) filler position profile 26 bending radius filler position R 15*) (1015) R 25 (1015) R>100 (1018) 28 15 405 gr/m 522 gr/m

Nadere informatie

Circulatiepompen voor de Glastuinbouw Pompgrafieken

Circulatiepompen voor de Glastuinbouw Pompgrafieken - orticulture Circulation umps erformance Curves Circulatiepompen voor de Glastuinbouw ompgrafieken. kw CL CLB z. kw / and / 9 rpm - - - - - - - - - A- - - - - - - - A- - A- - - - - -. kw - / and / [m/h

Nadere informatie

liniled Cast Joint liniled Gietmof liniled Castjoint

liniled Cast Joint liniled Gietmof liniled Castjoint liniled Cast Joint liniled Gietmof liniled is een hoogwaardige, flexibele LED strip. Deze flexibiliteit zorgt voor een zeer brede toepasbaarheid. liniled kan zowel binnen als buiten in functionele en decoratieve

Nadere informatie

SHP-TS TwinArc SA SHP-TS 400W TWINARC E40 SL PRODUCT OVERVIEW

SHP-TS TwinArc SA SHP-TS 400W TWINARC E40 SL PRODUCT OVERVIEW Range Features Range of high pressure sodium lamps with double arc tube construction Dual arc tube design guarantees immediate re-strike after a power interruption Doubled lamp life and reduced occurrence

Nadere informatie

SPX Model A-360 Azimuth Antenna Rotor Model 1 & 2

SPX Model A-360 Azimuth Antenna Rotor Model 1 & 2 Gauke Boelensstraat 108 NL-9203 RS Drachten The Netherlands Tel: +31 (0) 512 354 126 GSM: +31 (0) 650 882 889 Fax: +31 (0) 847 187 776 www.rfhamdesign.com E-mail: info@rfhamdesign.com Model A-360 Azimuth

Nadere informatie

De PROFIBUS, PROFINET & IO-Link dag. Edegem, 8 juni 2010. PROFIBUS Belgium VZW PROFIBUS, PROFINET & IO-Link

De PROFIBUS, PROFINET & IO-Link dag. Edegem, 8 juni 2010. PROFIBUS Belgium VZW PROFIBUS, PROFINET & IO-Link De PROFIBUS, PROFINET & IO-Link dag Edegem, 8 juni 2010 PROFIBUS Belgium VZW PROFIBUS, PROFINET & IO-Link 2010 2 Agenda 1. Omschrijving project 2. Voorstelling materialen 3. Redundancy 4. Visualisatie

Nadere informatie

AE1103 Statics. 25 January h h. Answer sheets. Last name and initials:

AE1103 Statics. 25 January h h. Answer sheets. Last name and initials: Space above not to be filled in by the student AE1103 Statics 09.00h - 12.00h Answer sheets Last name and initials: Student no.: Only hand in the answer sheets! Other sheets will not be accepted Write

Nadere informatie

SHP / SHP-T Standard and Basic PLUS

SHP / SHP-T Standard and Basic PLUS Range Features ErP compliant High Pressure Sodium Lamps Long life between 24,000 to 28,000 hours, T90 at 16,000 hours Strong performance with high reliability Car park, Street and Floodlighting applications

Nadere informatie

FRAME [UPRIGHT MODEL] / [DEPTH] / [HEIGHT] / [FINISH] TYPE OF BASEPLATE P Base plate BP80 / E alternatives: ZINC finish in all cases

FRAME [UPRIGHT MODEL] / [DEPTH] / [HEIGHT] / [FINISH] TYPE OF BASEPLATE P Base plate BP80 / E alternatives: ZINC finish in all cases FRAME XS UPRIGHT BASE PLATE UPRIGHT HORIZONTAL PROFILE DIAGONAL PROFILE DESCRIPTION A vertical structure consisting of 2 uprights, joined by a system of bracing profiles, and base plates intended to support

Nadere informatie

BE Nanoregistry Annual Public Report

BE Nanoregistry Annual Public Report 1 BE Nanoregistry Annual Public Report Carine Gorrebeeck FPS Health, Food Chain Safety & Environment 2 WHY? The objectives of the registry (a.o.): - Traceability: allow competent authorities to intervene

Nadere informatie

Besluitenlijst CCvD HACCP/ List of decisions National Board of Experts HACCP

Besluitenlijst CCvD HACCP/ List of decisions National Board of Experts HACCP Besluitenlijst CCvD HACCP/ List of decisions National Board of Experts HACCP Dit is de actuele besluitenlijst van het CCvD HACCP. Op deze besluitenlijst staan alle relevante besluiten van het CCvD HACCP

Nadere informatie

ABIFLEXX ROBOTIC SYSTEMS ENDLESS POSSIBILITIES

ABIFLEXX ROBOTIC SYSTEMS ENDLESS POSSIBILITIES ABIFLEXX ROBOTIC SYSTEMS ENDLESS POSSIBILITIES www.abi.nl Made in Holland ROBOTIC SYSTEMS ABIflexx Robotic Systems offer the following advantages Available as separate components or as a complete system,

Nadere informatie

MyDHL+ Van Non-Corporate naar Corporate

MyDHL+ Van Non-Corporate naar Corporate MyDHL+ Van Non-Corporate naar Corporate Van Non-Corporate naar Corporate In MyDHL+ is het mogelijk om meerdere gebruikers aan uw set-up toe te voegen. Wanneer er bijvoorbeeld meerdere collega s van dezelfde

Nadere informatie

Hoe maak ik mijn datacenterinfrastructuur cloud ready? Door: Bart Nieuwenhuis

Hoe maak ik mijn datacenterinfrastructuur cloud ready? Door: Bart Nieuwenhuis Hoe maak ik mijn datacenterinfrastructuur cloud ready? Door: Bart Nieuwenhuis Application: Data Center Fire Pump Controller Chillers Surge Protection Automatic Transfer Switch Uninterruptible Power Supplies

Nadere informatie

Innovatief monitoren van sportvelden. 31 mei 2018

Innovatief monitoren van sportvelden. 31 mei 2018 Innovatief monitoren van sportvelden 31 mei 2018 31 mei 2018 Met Intelligent Play een gegarandeerde levensduur en exploitatie van sportsportvelden Wim Glaap, Newae Alex Talton, Intelligent Play Sportvelden

Nadere informatie

Welkom bij de Partners van DAISY Jan Louws & Bob Versteeg

Welkom bij de Partners van DAISY Jan Louws & Bob Versteeg 1 Welkom bij de Partners van DAISY Jan Louws & Bob Versteeg Dynamic Asset Information System 2 Strong by cooperation State-of-the-art, independent, low cost 3 Aanleiding Oude situatie» Corrective maintenance»

Nadere informatie

Groene industrie POWER QUALITY POWER AND SIGNAL QUALITY. Phoenix Contact B.V. 2015-2016

Groene industrie POWER QUALITY POWER AND SIGNAL QUALITY. Phoenix Contact B.V. 2015-2016 Groene industrie Phoenix Contact B.V. 2015-2016 POWER AND SIGNAL QUALITY POWER QUALITY 24V PWR ERR 24V 0V 0V OUT I GND GND GND ON OFF 1 2 1A 5A NC PACT RCP- Rogowskisp Eerst Power Quality inzichtelijk

Nadere informatie

SPX AX-400 Azimuth & Elevation antenna rotator Model 1 & 2

SPX AX-400 Azimuth & Elevation antenna rotator Model 1 & 2 Gauke Boelensstraat 108 NL-9203 RS Drachten The Netherlands Tel: +31 (0) 512 354 126 GSM: +31 (0) 650 882 889 Fax: +31 (0) 847 187 776 www.rfhamdesign.com E-mail: info@rfhamdesign.com SPX AX-400 Azimuth

Nadere informatie

Agenda: Rotary Industry Group

Agenda: Rotary Industry Group KiC MPI 21juni 2018 Rotary Industry Group Agenda: a) Korte introductie: wie zijn wij wat doen wij? b) Nieuwe ontwikkelingen binnen Rotary Industry Group c) Contactloze magnetische koppeling d) Business

Nadere informatie

Opleiding PECB ISO 9001 Quality Manager.

Opleiding PECB ISO 9001 Quality Manager. Opleiding PECB ISO 9001 Quality Manager www.bpmo-academy.nl Wat is kwaliteitsmanagement? Kwaliteitsmanagement beoogt aan te sturen op het verbeteren van kwaliteit. Tevens houdt het zich bezig met het verbinden

Nadere informatie

PROJECT INFORMATION Building De Meerlanden Nieuweweg 65 in Hoofddorp

PROJECT INFORMATION Building De Meerlanden Nieuweweg 65 in Hoofddorp BT Makelaars Aalsmeerderweg 606 Rozenburg Schiphol Postbus 3109 2130 KC Hoofddorp Telefoon 020-3 166 166 Fax 020-3 166 160 Email: info@btmakelaars.nl Website : www.btmakelaars.nl PROJECT INFORMATION Building

Nadere informatie

Settings for the C100BRS4 MAC Address Spoofing with cable Internet.

Settings for the C100BRS4 MAC Address Spoofing with cable Internet. Settings for the C100BRS4 MAC Address Spoofing with cable Internet. General: Please use the latest firmware for the router. The firmware is available on http://www.conceptronic.net! Use Firmware version

Nadere informatie

RECEPTEERKUNDE: PRODUCTZORG EN BEREIDING VAN GENEESMIDDELEN (DUTCH EDITION) FROM BOHN STAFLEU VAN LOGHUM

RECEPTEERKUNDE: PRODUCTZORG EN BEREIDING VAN GENEESMIDDELEN (DUTCH EDITION) FROM BOHN STAFLEU VAN LOGHUM Read Online and Download Ebook RECEPTEERKUNDE: PRODUCTZORG EN BEREIDING VAN GENEESMIDDELEN (DUTCH EDITION) FROM BOHN STAFLEU VAN LOGHUM DOWNLOAD EBOOK : RECEPTEERKUNDE: PRODUCTZORG EN BEREIDING VAN STAFLEU

Nadere informatie

Remote sensor series

Remote sensor series Remote sensor series DATASHEET Sensor Partners BV James Wattlaan 15 5151 DP Drunen The Netherlands +1 ()1-7 9 info@sensorpartners.com sensorpartners.com Sensor Partners BVBA Z.1 Researchpark 1 B-1, Zellik

Nadere informatie

EE141- Spring 2004 Lecture 3 EE141. Last Lectures. Design Metrics

EE141- Spring 2004 Lecture 3 EE141. Last Lectures. Design Metrics - Spring 2004 Lecture Design Metrics 1 Last Lectures Moore s law Challenges in digital IC design in the next decade. Manufacturing process Today Design metrics 2 1 Administrivia If you have not signed-in

Nadere informatie

2019 SUNEXCHANGE USER GUIDE LAST UPDATED

2019 SUNEXCHANGE USER GUIDE LAST UPDATED 2019 SUNEXCHANGE USER GUIDE LAST UPDATED 0 - -19 1 WELCOME TO SUNEX DISTRIBUTOR PORTAL This user manual will cover all the screens and functions of our site. MAIN SCREEN: Welcome message. 2 LOGIN SCREEN:

Nadere informatie

Feedback WG System Operations 21 November 2012

Feedback WG System Operations 21 November 2012 Feedback WG System Operations 21 November 2012 User Group 06/12/2012 Wim Michiels Content Feedback IGCC Winter action plan Draft ENTSO-E winter outlook 2012 2013 Capaciteit noordgrens Overview of dynamic

Nadere informatie

Opgave 2 Geef een korte uitleg van elk van de volgende concepten: De Yield-to-Maturity of a coupon bond.

Opgave 2 Geef een korte uitleg van elk van de volgende concepten: De Yield-to-Maturity of a coupon bond. Opgaven in Nederlands. Alle opgaven hebben gelijk gewicht. Opgave 1 Gegeven is een kasstroom x = (x 0, x 1,, x n ). Veronderstel dat de contante waarde van deze kasstroom gegeven wordt door P. De bijbehorende

Nadere informatie

Quick start guide. Powerbank MI Mah. Follow Fast All rights reserved. Page 1

Quick start guide. Powerbank MI Mah. Follow Fast All rights reserved. Page 1 Quick start guide Powerbank MI 16.000 Mah Follow Fast 2016 - All rights reserved. Page 1 ENGLISH The Mi 16000 Power Bank is a very good backup option for those on the move. It can keep you going for days

Nadere informatie

PANEELRADIATOR - Type PR Handleiding. PANEL RADIATOR - Type PR Manual

PANEELRADIATOR - Type PR Handleiding. PANEL RADIATOR - Type PR Manual Fax. +31 (0)227-549 150 Website: www.sinusjevi.com PANEELRADIATOR - Type PR Handleiding PANEL RADIATOR - Type PR Manual Page 2 of 8 Page 3 of 8 Technische informatie Spanning: 230 of 400 Volt Vermogen:

Nadere informatie

Quality requirements concerning the packaging of oak lumber of Houthandel Wijers vof (09.09.14)

Quality requirements concerning the packaging of oak lumber of Houthandel Wijers vof (09.09.14) Quality requirements concerning the packaging of oak lumber of (09.09.14) Content: 1. Requirements on sticks 2. Requirements on placing sticks 3. Requirements on construction pallets 4. Stick length and

Nadere informatie

PRESTATIEVERKLARING. Nr NL. Bevestiging achteraf in gescheurd of ongescheurd beton, zie bijlage, in het bijzonder bijlages B 1 tot en met B 6

PRESTATIEVERKLARING. Nr NL. Bevestiging achteraf in gescheurd of ongescheurd beton, zie bijlage, in het bijzonder bijlages B 1 tot en met B 6 PRESTATIEVERKLARING Nr. 0020 NL 1. Unieke identificatiecode van het producttype: fischer High-Prestatie Anchor FH II, FH II-I 2. Beoogd(e) gebruik(en): Product Momentgecontroleerd spreidanker Beoogd gebruik

Nadere informatie

Intelli Air Valve (iav)

Intelli Air Valve (iav) Intelli Air Valve (iav) Intelligent control valve with CO 2 or humidity measurement NEW A compact solution for apartment blocks Quick and easy to install and maintain Ø 125 mm & Ø 160 mm Central or zonal

Nadere informatie

Presentation Fire fighter safety switch

Presentation Fire fighter safety switch Presentation Fire fighter safety switch 20 september 2011 Elsbeth Faasse Cor Jansen Santon Holland BV AGENDA SANTON INTRODUCTION PRODUCTS NEW DEVELOPMENTS The Fire fighter Safety Switch Introductie Diverse

Nadere informatie

BVBA POMAC-LUB-SERVICES SPRL Korte Bruggestraat 28 B-8970 Poperinge Tel. 057/33 48 36 Fax 057/33 61 27 info@pomac.be internet: www.pomac.

BVBA POMAC-LUB-SERVICES SPRL Korte Bruggestraat 28 B-8970 Poperinge Tel. 057/33 48 36 Fax 057/33 61 27 info@pomac.be internet: www.pomac. Smeersysteem voor conveyors Conveyors lubrication systems KS-007a-1-NE SMEERSYSTEEM VOOR MONO OF BIRAIL CONVEYORS Dit systeem is ontworpen voor het gedoseerd smeren van de lagers van de rollen van conveyors

Nadere informatie

SAMPLE 11 = + 11 = + + Exploring Combinations of Ten + + = = + + = + = = + = = 11. Step Up. Step Ahead

SAMPLE 11 = + 11 = + + Exploring Combinations of Ten + + = = + + = + = = + = = 11. Step Up. Step Ahead 7.1 Exploring Combinations of Ten Look at these cubes. 2. Color some of the cubes to make three parts. Then write a matching sentence. 10 What addition sentence matches the picture? How else could you

Nadere informatie

SPID Azimuth antenna rotator Type: RAK

SPID Azimuth antenna rotator Type: RAK Gauke Boelensstraat 108 NL-9203 RS Drachten The Netherlands Tel: +31 (0) 512 354 126 GSM: +31 (0) 650 882 889 Fax: +31 (0) 847 187 776 www.rfhamdesign.com E-mail: info@rfhamdesign.com SPID Azimuth antenna

Nadere informatie

Concept of Feedback. P.S. Gandhi Mechanical Engineering IIT Bombay

Concept of Feedback. P.S. Gandhi Mechanical Engineering IIT Bombay Concept of Feedback P.S. Gandhi Mechanical Engineering IIT Bombay Recap Goal of the course: understanding and learning Assignments: optional to start with Contact hour with TAs: Monday AN: time? Meeting

Nadere informatie

GOVERNMENT NOTICE. STAATSKOERANT, 18 AUGUSTUS 2017 No NATIONAL TREASURY. National Treasury/ Nasionale Tesourie NO AUGUST

GOVERNMENT NOTICE. STAATSKOERANT, 18 AUGUSTUS 2017 No NATIONAL TREASURY. National Treasury/ Nasionale Tesourie NO AUGUST National Treasury/ Nasionale Tesourie 838 Local Government: Municipal Finance Management Act (56/2003): Draft Amendments to Municipal Regulations on Minimum Competency Levels, 2017 41047 GOVERNMENT NOTICE

Nadere informatie

WATERDICHT KOPPELBAAR OPBOUWARMATUUR

WATERDICHT KOPPELBAAR OPBOUWARMATUUR WATERDICHT KOPPELBAAR OPBOUWARMATUUR WATERPROOF LINKABLE MOUNTED LUMINAIRE LED PRO-AREA SERIE LED PRO-AREA SERIES Het Prolumia Pro-Area waterdichte LED opbouwarmatuur (IP65) is hét alternatief voor waterdichte

Nadere informatie

BREEDVELD & WEAVER HYDRAULICS

BREEDVELD & WEAVER HYDRAULICS GENERAL SALES APPLICATION TECHNISCHE HANDELSONDERNEMING BREEDVELD & WEAVER HYDRAULICS Revision and repair of hydraulics Already 50 years of experience in repairing hydraulic components. We are especially

Nadere informatie

Create emotions with lighting

Create emotions with lighting 1 nuudo. nuudo. een merk dat ontstaan is uit passie voor hoogwaardig afgewerkte producten in combinatie met innovatieve oplossingen om een perfect lichtbeeld te creëren. Met het oog van een vakman en het

Nadere informatie

I.S.T.C. Intelligent Saving Temperature Controler

I.S.T.C. Intelligent Saving Temperature Controler MATEN & INFORMATIE I.S.T.C. Intelligent Saving Temperature Controler Deze unieke modulerende zender, als enige ter wereld, verlaagt het energieverbruik aanzienlijk. Het werkt in combinatie met de energy

Nadere informatie

PIR DC-SWITCH. DC Passive infra-red Detector. Model No. PDS-10 GEBRUIKSAANWIJZING/INSTRUCTION MANUAL

PIR DC-SWITCH. DC Passive infra-red Detector. Model No. PDS-10 GEBRUIKSAANWIJZING/INSTRUCTION MANUAL PIR DC-SWITCH DC Passive infra-red Detector Model No. PDS-10 GEBRUIKSAANWIJZING/INSTRUCTION MANUAL Please read this manual before operating your DETECTOR PIR DC-Switch (PDS-10) De PDS-10 is een beweging

Nadere informatie

HANDLEIDING - ACTIEVE MOTORKRAAN

HANDLEIDING - ACTIEVE MOTORKRAAN M A N U A L HANDLEIDING - ACTIEVE MOTORKRAAN MANUAL - ACTIVE MOTOR VALVE Model E710877 E710878 E710856 E710972 E710973 www.tasseron.nl Inhoud / Content NEDERLANDS Hoofdstuk Pagina NL 1 ALGEMEEN 2 NL 1.1

Nadere informatie

2000 Volkswagen Passat GLS

2000 Volkswagen Passat GLS REAR DOOR WINDOW Rear door window, assembly overview Fig. 304: Exploded View Of Rear Door Window 1 - Door Removing and installing: --> Rear door, removing and installing 2 - Spring nut Qty 2 3 - Screw

Nadere informatie

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 2+

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 2+ PRESTATIEVERKLARING Nr. 0031 NL 1. Unieke identificatiecode van het producttype: fischer nail anchor FNA II 2. Beoogd(e) gebruik(en): Product Metalen ankers voor gebruik in beton (lichte lasten) Beoogd

Nadere informatie

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 2+

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 2+ PRESTATIEVERKLARING Nr. 0016 NL 1. Unieke identificatiecode van het producttype: fischer betonschroef FBS 5 en FBS 6 2. Beoogd(e) gebruik(en): Product Metalen ankers voor gebruik in beton (lichte lasten)

Nadere informatie

Notitie : In de grond gevormde palen met grondverwijdering

Notitie : In de grond gevormde palen met grondverwijdering Notitie : In de grond gevormde palen met grondverwijdering Waarom een notitie? Waarom een notitie? Onduidelijkheid van de norm? Waarom een notitie? Onduidelijkheid van de norm? of Landelijk handelen volgens

Nadere informatie

NAMI LIFT SPARE PART LIST DATE

NAMI LIFT SPARE PART LIST DATE Part No Group Description Photo 5404000 Door Power door operator 5404001 Door -- -- arm 5404002 Door -- -- sliding shoe 5404003 Door -- -- guiding track 5404004 Door -- -- circuit board 5401002 Door Manual

Nadere informatie

Today s class. Digital Logic. Informationsteknologi. Friday, October 19, 2007 Computer Architecture I - Class 8 1

Today s class. Digital Logic. Informationsteknologi. Friday, October 19, 2007 Computer Architecture I - Class 8 1 Today s class Digital Logic Friday, October 19, 2007 Computer Architecture I - Class 8 1 Digital circuits Two logical values Binary 0 (signal between 0 and 1 volt) Binary 1 (signal between 2 and 5 volts)

Nadere informatie

SNMV-H made for your process

SNMV-H made for your process Vertical, radially split volute casing type, single stage, end suction centrifugal pump with enclosed impeller made for your process Handled Liquids type pumps are suitable for clean or slightly contaminated

Nadere informatie

PRESTATIEVERKLARING. Nr NL. Bevestiging achteraf in gescheurd of ongescheurd beton, zie bijlage, in het bijzonder bijlages B 1 tot en met B 4

PRESTATIEVERKLARING. Nr NL. Bevestiging achteraf in gescheurd of ongescheurd beton, zie bijlage, in het bijzonder bijlages B 1 tot en met B 4 PRESTATIEVERKLARING Nr. 0081 NL 1. Unieke identificatiecode van het producttype: fischer Doorsteek anker FAZ II 2. Beoogd(e) gebruik(en): Product Momentgecontroleerd spreidanker Beoogd gebruik Bevestiging

Nadere informatie

Laboratory report. Independent testing of material surfaces. Analysis of leaching substances in treated wood samples conform guide line EU 10/2011

Laboratory report. Independent testing of material surfaces. Analysis of leaching substances in treated wood samples conform guide line EU 10/2011 Independent testing of material surfaces Laboratory report Analysis of leaching substances in treated wood samples conform guide line EU 10/2011 Customer Wasziederij De Vesting BV Trasweg 12 5712 BB Someren-Eind

Nadere informatie

Chapter 4 Understanding Families. In this chapter, you will learn

Chapter 4 Understanding Families. In this chapter, you will learn Chapter 4 Understanding Families In this chapter, you will learn Topic 4-1 What Is a Family? In this topic, you will learn about the factors that make the family such an important unit, as well as Roles

Nadere informatie

Alfa Laval presenteert. een nieuw DNA...

Alfa Laval presenteert. een nieuw DNA... Alfa Laval presenteert een nieuw DNA... Optigo CS Optigo CS CSE201B7-Opties Vin afstand : 4mm, 7mm Type batterij : B, C, E Aantal fans :1, 2, 3, 4, 5 Fan diameter : 20=200mm, 30=300mm Structuur artikelnummer

Nadere informatie

L.Net s88sd16-n aansluitingen en programmering.

L.Net s88sd16-n aansluitingen en programmering. De L.Net s88sd16-n wordt via één van de L.Net aansluitingen aangesloten op de LocoNet aansluiting van de centrale, bij een Intellibox of Twin-Center is dat de LocoNet-T aansluiting. L.Net s88sd16-n aansluitingen

Nadere informatie

Classification of triangles

Classification of triangles Classification of triangles A triangle is a geometrical shape that is formed when 3 non-collinear points are joined. The joining line segments are the sides of the triangle. The angles in between the sides

Nadere informatie

Product naam: MM03829

Product naam: MM03829 Product naam: Specificaties : Levensduur: 25000u Wattage: 3.00W Kleur: 2800K (warmwit) Lumen: 180 lu RA: 80 Lamp soort: G9 Lampvoet: GU9 Lengte: Diameter: Gewicht: Spanning: Stroom uit: Beschermingsklasse:

Nadere informatie

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 1

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 1 PRESTATIEVERKLARING Nr. 0036 NL 1. Unieke identificatiecode van het producttype: fischer Zykon-Hammerset anchor FZEA II 2. Beoogd(e) gebruik(en): Product Metalen ankers voor gebruik in beton (zware lasten)

Nadere informatie

2006 Volkswagen Jetta TDI

2006 Volkswagen Jetta TDI Door handle and door lock, assembly overview The illustration shows the left side. The right side is derived accordingly from this. Fig. 99: Door Handle And Door Lock, Assembly Overview 1 - Cable For disengaging

Nadere informatie

CHROMA STANDAARDREEKS

CHROMA STANDAARDREEKS CHROMA STANDAARDREEKS Chroma-onderzoeken Een chroma geeft een beeld over de kwaliteit van bijvoorbeeld een bodem of compost. Een chroma bestaat uit 4 zones. Uit elke zone is een bepaald kwaliteitsaspect

Nadere informatie

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 1

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 1 PRESTATIEVERKLARING Nr. 0005 NL 1. Unieke identificatiecode van het producttype: fischer Inslag anker EA II 2. Beoogd(e) gebruik(en): Product Metalen ankers voor gebruik in beton (zware lasten) Beoogd

Nadere informatie

DECLARATION FOR GAD approval

DECLARATION FOR GAD approval Version 1.2 DECLARATION FOR GAD approval Declare that for the following central heating boilers Intergas Calderas de Calefacción S. L. Kombi Kompakt R 24, 28/24, 36/30 and Prestige The installation and

Nadere informatie

Puurs Logistics Centre. 25,000 sqm built-to-suit development opportunity on the Antwerp-Brussels axis. build your future+

Puurs Logistics Centre. 25,000 sqm built-to-suit development opportunity on the Antwerp-Brussels axis. build your future+ Puurs Logistics Centre 25,000 sqm built-to-suit development opportunity on the Antwerp-Brussels axis build your future+ Puurs Logistics Centre Brabantstraat 2, 2870 Puurs Puurs Logistics Centre Brabantstraat

Nadere informatie

MCP-16RC, luchtzuiveringstoren

MCP-16RC, luchtzuiveringstoren Compact cartridge filter with pulse cleaning De MCP-16RC luchtzuiveringstoren is een compacte patroonfilter voor gedecentraliseerde reiniging van binnenlucht, waar terugwinnen van lucht mogelijk is. Het

Nadere informatie

Opleiding PECB IT Governance.

Opleiding PECB IT Governance. Opleiding PECB IT Governance www.bpmo-academy.nl Wat is IT Governance? Information Technology (IT) governance, ook wel ICT-besturing genoemd, is een onderdeel van het integrale Corporate governance (ondernemingsbestuur)

Nadere informatie

SPID Azimuth antenna rotator Type: BIG-RAK

SPID Azimuth antenna rotator Type: BIG-RAK SPID Azimuth antenna rotator Type: BIG-RAK Specifications: SPID BIG RAK PWM Azimuth Rotator BIG RAK @ 12V BIG RAK @ 18V Turning torque in-lbs/nm 2,800 in lb/315 Nm 3,600 in lb/403 Nm Brake Torque in lbs/nm

Nadere informatie

Centrifugal Sanitary Pumps. CL - CLC series

Centrifugal Sanitary Pumps. CL - CLC series Centrifugal Sanitary Pumps CL CLC series Centrifugal Sanitary Pumps CLCLC series Standard design Available in a wide range of models with closed or open impellers and 2 or pole motors, this wellestablished

Nadere informatie

SAP Exchange Infrastructure. SAP Partner Connectivity Kit Overview

SAP Exchange Infrastructure. SAP Partner Connectivity Kit Overview SAP Exchange Infrastructure SAP Partner Connectivity Kit Overview SAP Partner Connectivity Kit Overview Enablement of smaller companies / subsidiaries to exchange XML documents with their business partner

Nadere informatie

Wilvo heeft zich sinds de oprichting in 1970 continu ontwikkeld. Het resultaat is haar huidige vooraanstaande rol binnen de toeleveringswereld.

Wilvo heeft zich sinds de oprichting in 1970 continu ontwikkeld. Het resultaat is haar huidige vooraanstaande rol binnen de toeleveringswereld. S H E E T M E T A L p a r t s a n d a s s e m b l i e s I n t r o d u c t i e Wilvo heeft zich sinds de oprichting in 1970 continu ontwikkeld. Het resultaat is haar huidige vooraanstaande rol binnen de

Nadere informatie

Adventures in GIS to Support LEED Certification. Karen Jordan

Adventures in GIS to Support LEED Certification. Karen Jordan Adventures in GIS to Support LEED Certification Karen Jordan Agenda University of California Office of the President commitment to Campus Sustainability through the Green Building Policy & Clean Energy

Nadere informatie

Building the next economy met Blockchain en real estate. Lelystad Airport, 2 november 2017 BT Event

Building the next economy met Blockchain en real estate. Lelystad Airport, 2 november 2017 BT Event Building the next economy met Blockchain en real estate Lelystad Airport, 2 november 2017 Blockchain en real estate Programma Wat is blockchain en waarvoor wordt het gebruikt? BlockchaininRealEstate Blockchain

Nadere informatie

Report for D-Sheet Piling 9.2

Report for D-Sheet Piling 9.2 Report for D-Sheet Piling 9.2 Design of Sheet Pilings Developed by Deltares Company: RPS advies en ingenieurs bv Date of report: 10/2/2013 Time of report: 4:03:39 PM Date of calculation: 10/2/2013 Time

Nadere informatie

SPL D2 MKII GEBRUIKSAANWIJZING USER MANUAL

SPL D2 MKII GEBRUIKSAANWIJZING USER MANUAL SPL D2 MKII GEBRUIKSAANWIJZING USER MANUAL Spl-D2 Next generation Inleiding De SPL5-D2 unit is een geluidsdrukmeter die gekoppeld kan worden aan de SPL5. Het apparaat kan ook als losse geluidsdrukmeter

Nadere informatie

Process Mining and audit support within financial services. KPMG IT Advisory 18 June 2014

Process Mining and audit support within financial services. KPMG IT Advisory 18 June 2014 Process Mining and audit support within financial services KPMG IT Advisory 18 June 2014 Agenda INTRODUCTION APPROACH 3 CASE STUDIES LEASONS LEARNED 1 APPROACH Process Mining Approach Five step program

Nadere informatie

SPID Azimuth Antenna rotator Type: RAK/HR

SPID Azimuth Antenna rotator Type: RAK/HR WWW.RFHAMDESIGN.COM SPID Azimuth Antenna rotator Type: RAK/HR SPID RAK/HR MD-02 Rotor Controller Type RAK/HR is a 1 engine rotor system (Azimuth) and delivered including: RAK/HR rotor 0.2 degree resolution

Nadere informatie

L.Net s88sd16-n aansluitingen en programmering.

L.Net s88sd16-n aansluitingen en programmering. De L.Net s88sd16-n wordt via één van de L.Net aansluitingen aangesloten op de LocoNet aansluiting van de centrale, bij een Intellibox of Twin-Center is dat de LocoNet-T aansluiting. L.Net s88sd16-n aansluitingen

Nadere informatie

PRESTATIEVERKLARING. Nr NL. bijlages B 1 tot en met B 4

PRESTATIEVERKLARING. Nr NL. bijlages B 1 tot en met B 4 PRESTATIEVERKLARING Nr. 0069 NL 1. Unieke identificatiecode van het producttype: fischer Inslag anker EA II 2. Beoogd(e) gebruik(en): Product Metalen ankers voor gebruik in beton (zware lasten) Beoogd

Nadere informatie

AVG / GDPR -Algemene verordening gegevensbescherming -General data Protection Regulation

AVG / GDPR -Algemene verordening gegevensbescherming -General data Protection Regulation AVG / GDPR -Algemene verordening gegevensbescherming -General data Protection Regulation DPS POWER B.V. 2018 Gegevensbeschermingsmelding Wij, DPS POWER B.V., beschouwen de bescherming van uw persoonlijke

Nadere informatie

ANGSTSTOORNISSEN EN HYPOCHONDRIE: DIAGNOSTIEK EN BEHANDELING (DUTCH EDITION) FROM BOHN STAFLEU VAN LOGHUM

ANGSTSTOORNISSEN EN HYPOCHONDRIE: DIAGNOSTIEK EN BEHANDELING (DUTCH EDITION) FROM BOHN STAFLEU VAN LOGHUM Read Online and Download Ebook ANGSTSTOORNISSEN EN HYPOCHONDRIE: DIAGNOSTIEK EN BEHANDELING (DUTCH EDITION) FROM BOHN STAFLEU VAN LOGHUM DOWNLOAD EBOOK : ANGSTSTOORNISSEN EN HYPOCHONDRIE: DIAGNOSTIEK STAFLEU

Nadere informatie

MANHATTAN RENTAL MARKET REPORT

MANHATTAN RENTAL MARKET REPORT MANHATTAN RENTAL MARKET REPORT JANUARY 2019 TABLE OF CONTENTS 03 INTRODUCTION 04 A QUICK LOOK 07 MEAN MANHATTAN RENTAL PRICES 11 MANHATTAN PRICE TRENDS 12 NEIGHBORHOOD PRICE TRENDS 12 BATTERY PARK CITY

Nadere informatie

WWW.EMINENT-ONLINE.COM

WWW.EMINENT-ONLINE.COM WWW.EMINENT-OINE.COM HNDLEIDING USERS MNUL EM1016 HNDLEIDING EM1016 USB NR SERIEEL CONVERTER INHOUDSOPGVE: PGIN 1.0 Introductie.... 2 1.1 Functies en kenmerken.... 2 1.2 Inhoud van de verpakking.... 2

Nadere informatie

FOD VOLKSGEZONDHEID, VEILIGHEID VAN DE VOEDSELKETEN EN LEEFMILIEU 25/2/2016. Biocide CLOSED CIRCUIT

FOD VOLKSGEZONDHEID, VEILIGHEID VAN DE VOEDSELKETEN EN LEEFMILIEU 25/2/2016. Biocide CLOSED CIRCUIT 1 25/2/2016 Biocide CLOSED CIRCUIT 2 Regulatory background and scope Biocidal products regulation (EU) nr. 528/2012 (BPR), art. 19 (4): A biocidal product shall not be authorised for making available on

Nadere informatie

Interface tussen Stuurbediening en Sony autoaudio

Interface tussen Stuurbediening en Sony autoaudio The information in this document is in Dutch, English version follows later in this document Interface tussen Stuurbediening en Sony autoaudio LET OP! HOEWEL DE UITERSTE ZORGVULDIGHEID IS BETRACHT BIJ

Nadere informatie

MyDHL+ ProView activeren in MyDHL+

MyDHL+ ProView activeren in MyDHL+ MyDHL+ ProView activeren in MyDHL+ ProView activeren in MyDHL+ In MyDHL+ is het mogelijk om van uw zendingen, die op uw accountnummer zijn aangemaakt, de status te zien. Daarnaast is het ook mogelijk om

Nadere informatie

Product naam: MM01315

Product naam: MM01315 Product naam: MM01315 Specificaties MM01315 : Groep rmatuur Soort Buiten rmaturen Levensduur L90 15.000u R 82 Wattage 15W Beschermingsgraad IP65 Lichtkleur 2700K (warmwit) Lengte 518mm Fitting Diameter

Nadere informatie

liniled Marker Light Power Short Pitch

liniled Marker Light Power Short Pitch liniled Marker Light Power Short Pitch 2700K 3000K Natural White 4000K Cold White 6500K liniled Markeerlicht Power Short Pitch liniled Markeerlichten zijn uitermate geschikt om een route of locatie te

Nadere informatie

ISA SP-99 Manufacturing and Control Systems Security

ISA SP-99 Manufacturing and Control Systems Security ISA SP-99 Manufacturing and Control Systems Security IT Security in de industrie, 11 mei 2006 Standards Certification Education & Training Publishing Conferences & Exhibits Bianca Scholten, ISA Netherlands

Nadere informatie

CTI SUITE TSP DETAILS

CTI SUITE TSP DETAILS CTI SUITE TSP DETAILS TAPI allows an application to access telephony services provided by a telecom PABX. In order to implement its access to ETRADEAL, a TAPI interface has been developed by Etrali. As

Nadere informatie

STRESS CORROSION CRACKING OF WELDED JOINTS OF Al-Mg ALLOYS

STRESS CORROSION CRACKING OF WELDED JOINTS OF Al-Mg ALLOYS Journal of KONES Powertrain and Transport, Vol. 21, No. 3 2014 ISSN: 1231-4005 e-issn: 2354-0133 ICID: 1133154 DOI: 10.5604/12314005.1133154 STRESS CORROSION CRACKING OF WELDED JOINTS OF Al-Mg ALLOYS Gdynia

Nadere informatie

AE1103 Statics. 3 November h h. Answer sheets. Last name and initials:

AE1103 Statics. 3 November h h. Answer sheets. Last name and initials: Space above not to be filled in by the student AE1103 Statics 09.00h - 12.00h Answer sheets Last name and initials: Student no.: Only hand in the answer sheets! Other sheets will not be accepted Write

Nadere informatie

Integratie van Due Diligence in bestaande risicomanagementsystemen volgens NPR 9036

Integratie van Due Diligence in bestaande risicomanagementsystemen volgens NPR 9036 Integratie van Due Diligence in bestaande risicomanagementsystemen volgens NPR 9036 NCP contactdag, 19 april 2016 Thamar Zijlstra, Dick Hortensius NEN Milieu en Maatschappij Agenda Achtergrond NPR 9036

Nadere informatie

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 2+

PRESTATIEVERKLARING. Nr NL. 5. Het systeem of de systemen voor de beoordeling en verificatie van de prestatiebestendigheid: 2+ PRESTATIEVERKLARING Nr. 0003 NL 1. Unieke identificatiecode van het producttype: fischer Inslag anker EA II 2. Beoogd(e) gebruik(en): Product Metalen ankers voor gebruik in beton (lichte lasten) Beoogd

Nadere informatie

Lichamelijke factoren als voorspeller voor psychisch. en lichamelijk herstel bij anorexia nervosa. Physical factors as predictors of psychological and

Lichamelijke factoren als voorspeller voor psychisch. en lichamelijk herstel bij anorexia nervosa. Physical factors as predictors of psychological and Lichamelijke factoren als voorspeller voor psychisch en lichamelijk herstel bij anorexia nervosa Physical factors as predictors of psychological and physical recovery of anorexia nervosa Liesbeth Libbers

Nadere informatie

Esther Lee-Varisco Matt Zhang

Esther Lee-Varisco Matt Zhang Esther Lee-Varisco Matt Zhang Want to build a wine cellar Surface temperature varies daily, seasonally, and geologically Need reasonable depth to build the cellar for lessened temperature variations Building

Nadere informatie